Super 8 (whirlpool)
N96W17490 COUNTY LINE RD, Germantown, WI 53022 · Washington County
Establishment
- Type
- Pool / recreational water (Pool - Moderate)
- Inspected by
- Washington Ozaukee Public Health
- License / ID
- HSAT-7QWAPQ
- Status
- Permitted
- Phone
- (262) 255-0880
- Official record
- Washington Ozaukee Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 2 | 0 |
| 2024 | 2 | 8 | 3 |
| 2023 | 1 | 0 | 0 |
Inspections
-
Jan 23, 2026 Routine · 2 non-critical
-
Not serious
Non-critical
REAGENTS STORAGE CONTAINER
The two reagents (R-0872 and R-0870) used for testing the spa sanitizer level were not being stored in good condition. The physical R-0870 chemical was in large chunks and no longer a fine powder as shipped from the manufacturer. The container (I sized vial) was dirty and was being used for refills from a J sized container. It was apparent that the I sized vial was not being cleaned properly between refills. The R-0872 bottle was in poor condition and the size of drop the bottle was dispensing appeared to be larger then what the manufacturer designed the product for. In addition, the poor condition of the bottle prevented the sanitarian from being able to read the expiration date.
Correction: After obtaining significantly different readings with both the health dept. kit and the facility kit with both the operator and sanitarian conducting tests, it became likely that one kit was not in good condition. The facility did have an unopened unexpired bottle of R-0872 and in-date good condition R-0870 from the J sized container. After taking an additional test with these new reagents, the re
Code ATCP 76.17 (2)(a) - REAGENT STORAGE BOTTLES
-
Not serious
Non-critical
OPERATOR RESPONSIBILITIES
The operator was unaware of proper testing procedures for sanitizer residual in the spa. The operator was using R-0872 and R-0870 reagents to conduct the test, but was not using the proper drops to PPM multiplier resulting in the operator recording readings that were not accurate on the logs.
Correction: The pool operator should obtain training and instructions on how to use the test kit properly. At the 25mL mark, each drop of R-0872 results in 0.5 PPM of bromine present in the water.
Code ATCP 76.20(1)(b) - OPERATOR RESPONSIBILITIES
-
Not serious
Non-critical
-
Nov 18, 2024 Routine · 2 critical, 4 non-critical
-
Not serious
Non-critical
INTERLOCK LOG-MADE AVAILABLE
While facility noted that an interlock challenge was done this month, and staff described their process, the log was not marked for this month so the inspector was unable to verify the challenge via paperwork.
Correction: Mark the interlock test log when completed so it is available to the department or its agent upon request.
Code ATCP 76.13 (1)(c)4.b - INTERLOCK LOG AVAILABLE
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 50 ppm.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
TEST KIT APPROVED
The facility is using a Taylor K-2005 style test kit for taking bromine reading in the spa. This type of kit does not meet the requirements of the code and is not approved by the department.
Correction: If continuing to use a Taylor kit, use the K-2006 style kit for taking bromine readings. You are already doing this style of testing with the pool. The only difference is use the R-0872 FAS-DPD titrating reagent for bromine instead of the R-0871 reagent used with chlorine. At the 25mL mark, each drop with the R-0872 liquid is 0.5PPM total bromine.
Code ATCP 76.17 (1) - DEPARTMENT-APPROVED
-
Not serious
Non-critical
FILES MAINTAINED PERMANENT-ATCP 76 CURRENT COPY
A copy of the most current version of ch. ATCP 76 was not permanently maintained on premises.
Correction: Maintain a copy of the most current version of ch. ATCP 76 on premises.
Code ATCP 76.32(3)(a)1. - CURRENT ATCP 76 COPY
-
Serious
Critical
Corrected on site
PH
The pH when tested with a Taylor kit is 7.0. In accordance with DATCP guidance document REC-GUD-007, the pool must be closed until the operator makes adjustments to bring the pool pH to 7.4 or 7.6.
Correction: Maintain the pH at 7.2 to 7.8. This issue was corrected and the water pH was brought to 7.4
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
Corrected on site
DRINKING FOUNTAIN PROVIDED
The drinking fountain is covered with a plastic bag and the water is turned off to the unit.
Correction: Provide a drinking fountain that is functional.
Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED
-
Not serious
Non-critical
-
Apr 12, 2024 Routine · 1 critical, 1 non-critical
-
Not serious
Non-critical
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept.
Correction: Keep a log of monthly interlock tests.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Serious
Critical
HAZARDOUS CONDITION
There is a hazardous condition at the pool. The three VGBA side covers are expired.
Correction: Correct the hazardous condition by replacing the VGBA side covers.
Code ATCP 76.34(1) - HAZARDOUS CONDITION AT POOL AREA
-
Not serious
Non-critical
-
Jun 6, 2023 Routine · No items found
No violations cited.
Source: Washington Ozaukee Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.