Lake Park Homes Association
W164N11493 SQUIRE DR, Germantown, WI 53022 · Washington County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- Washington Ozaukee Public Health
- License / ID
- HSAT-7QXLPE
- Status
- Permitted
- Phone
- (262) 255-1010
- Official record
- Washington Ozaukee Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 0 | 0 |
| 2025 | 1 | 2 | 1 |
| 2024 | 2 | 2 | 0 |
| 2023 | 1 | 1 | 1 |
Inspections
-
Jun 12, 2026 Routine · No items found
No violations cited.
-
Jun 17, 2025 Routine · 1 critical, 1 non-critical
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flowmeter is not being maintained in operating condition. The meter is struck.
Correction: Adjust or repair the flowmeter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Serious
Critical
Corrected on site
MINIMUM DISINFECTANT RESIDUAL
The sanitizer level was at 0.8 PPM at the start of the inspection taken from the controller port. At a point during the inspection, the controller kicked on the chlorine feed pump. Sanitarian waited until the feeder stopped adding chlorine and took another reading at the controller port which was in compliance.
Correction: A reminder that the pool must be closed if the disinfectant level is not in compliance with ATCP 76.14 Table A. For this pool with stabilizer used and a controller present that is 1.0 PPM.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Not serious
Non-critical
-
Jul 1, 2024 Follow Up · No items found
No violations cited.
-
Jun 21, 2024 Routine · 2 non-critical
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
-
Jun 19, 2023 Routine · 1 critical
-
Serious
Critical
Corrected on site
SKIMMER COVERS NOT SECURE
Side wall grates are beyond expiration date for VGBA requirements
Correction: Replace SDX covers within the next 30 days. Facility able to provide proof of replacement the day after the initial inspection.
Code [C] ATCP 76.11(2)(b)
-
Serious
Critical
Corrected on site
Source: Washington Ozaukee Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.