6cited violations
2serious tier
4inspections

Establishment

Type
Pool / recreational water (Pool - Complex with Features)
Inspected by
Washington Ozaukee Public Health
License / ID
HSAT-7QX4XB
Status
Permitted
Phone
(262) 242-1591
Official record
Washington Ozaukee Public Health inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026111
2025131
2024110
2023110

Inspections

  1. Jun 9, 2026 Routine · 1 critical
    • Serious Critical

      OPERATOR KNOWLEDGE-MONTHLY TESTING

      The person responsible is not able to describe how monthly testing is performed.

      Correction: Ensure that operator can describe how monthly testing is performed.

      Code ATCP 76.13 (1)(c)2.d - MONTHLY TESTING

  2. Jun 10, 2025 Routine · 1 critical, 2 non-critical
    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flow meter stuck is not being maintained in operating condition. Repair flow meter.

      Correction: Adjust or repair the repair flow meter..

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical

      VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT

      The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement. [Describe].

      Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.

      Code ATCP 76.38(2)(a) - DRAIN COVER LOG

    • Serious Critical

      CPR/AED CERTIFICATION, LIFEGUARD

      The lifeguard does not have an approved CPR with AED certificate. Several lifeguards have expired American redcross certs over a year old.

      Correction: Provide lifeguards who have approved CPR with AED certifications and adjust pool operation or close the pool until adequate lifeguard staffing can be provided. Those guards who have certs over a year cannot guard until they complete an approved CPR certification.

      Code ATCP 76.22(2)(a)3. - CPR CERTIFICATION REQUIRED

  3. Jun 20, 2024 Routine · 1 non-critical
    • Not serious Non-critical

      VGBA DRAIN COVER INFO-INSTALLATION DATE

      The VGBA log or other proof does not indicate drain cover installation date. Pool company or the assocation could not locate any information on the main drain covers. the covers are still in good conditions since we dont know the age and installation date they will need to be replaced at season end.

      Correction: Indicate in the log of drain cover installation date.

      Code ATCP 76.38(2)(b)5. - INSTALL DATE

  4. Jun 27, 2023 Routine · 1 non-critical
    • Not serious Non-critical

      FLOWMETER, VALVES AND GAUGES NOT FUNCTIONAL

      The flowmeter is stuck and not working.

      Correction: Repair or replace the specified equipment so an accurate reading can be recorded.

      Code ATCP 76.11(5)

Source: Washington Ozaukee Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.