RecordWell Data

Kinderberg Park Sprayground

N104W14942 DONGES BAY RD, Germantown, WI 53022

14cited violations
3serious tier
5inspections

Establishment

Type
Pool / recreational water (Pool - Simple with Features)
Inspected by
Washington Ozaukee Public Health
License / ID
HSAT-7QXJPL
Status
Permitted
Phone
(262) 250-4710
Official record
Washington Ozaukee Public Health inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026282
2025130
2024131
2023100

Inspections

  1. Jul 27, 2026 Admin Follow Up · 3 non-critical, 3 repeat
    • Not serious Non-critical Repeat

      INTERLOCK-LOG KEPT

      A log of the monthly interlock tests is not being kept.

      Correction: Keep a log of monthly interlock tests. This can easily be accomplished by marking the box listed as pump safety check on the daily log when interlock testing is completed.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

    • Not serious Non-critical Repeat

      ALKALINITY

      The total alkalinity is 50 ppm.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water (water saturation index).

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical Repeat

      OPERATING REPORTS-BACKWASH

      The operator did not record the following on the operating report: The dates on which backwashing was completed.

      Correction: Record the following on the operating report, the dates when backwashing was completed.

      Code ATCP 76.32(1)(b) - BACKWASH

  2. Jul 20, 2026 Routine · 2 critical, 3 non-critical, 2 repeat
    • Not serious Non-critical Repeat

      INTERLOCK-LOG KEPT

      A log of the monthly interlock tests is not being kept.

      Correction: Keep a log of monthly interlock tests. This can easily be accomplished by marking the box listed as pump safety check on the daily log when interlock testing is completed.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

    • Not serious Non-critical Repeat

      ALKALINITY

      The total alkalinity is 50 ppm.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water (water saturation index).

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical

      OPERATING REPORTS-BACKWASH

      The operator did not record the following on the operating report: The dates on which backwashing was completed.

      Correction: Record the following on the operating report, the dates when backwashing was completed.

      Code ATCP 76.32(1)(b) - BACKWASH

    • Serious Critical

      UV LIGHT SYSTEM

      Ultraviolet light unit is not properly functioning. Unit not meeting NSF/ANSI 50 efficacy requirement in current state.

      Correction: Repair the UV unit to clear error codes.

      Code ATCP 76.15 (3) - UV LIGHT

    • Serious Critical

      TELEPHONE ACCESSIBLE

      The auto dial emergency phone is contacting the Germantown Police Department who no longer operates emergency dispatch. The Village recently changed emergency dispatch to Washington County.

      Correction: Program the auto dial emergency phone so it connects to dispatch / 911.

      Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE

  3. Jul 16, 2025 Routine · 3 non-critical, 2 repeat
    • Not serious Non-critical Repeat Corrected on site

      INTERLOCK-LOG KEPT

      A log of the monthly interlock tests is not being kept. The log is not being marked every month indicating a test has been compleated.

      Correction: Keep a log of monthly interlock tests. Staff did update the log during the inspection.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

    • Not serious Non-critical

      ALKALINITY

      The total alkalinity is 50 ppm.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical Repeat Corrected on site

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool. This was completed after the inspection before this report was sent out. Staff have posted a copy of the plan on the facility bulletin board.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

  4. Jun 21, 2024 Routine · 1 critical, 2 non-critical
    • Not serious Non-critical

      INTERLOCK-LOG KEPT

      While the operator was able to successfully describe how the facility challange tests the interlock, the facility is not marking this on the pool logs.

      Correction: Keep a log of monthly interlock tests.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Serious Critical Corrected on site

      MINIMUM DISINFECTANT RESIDUAL

      Minimum disinfectant or sanitizer level is 0.6 ppm.

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A. Before the inspection was over, the operator was able to bring the sanitizer level to an approved amount.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

  5. Jun 14, 2023 Routine · No items found

    No violations cited.

Source: Washington Ozaukee Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.