Best Western Germantown Inn (whirlpool)

W190N10862 COMMERCE CIR, Germantown, WI 53022 · Washington County

37cited violations
5serious tier
4inspections

Establishment

Type
Pool / recreational water (Pool - Moderate)
Inspected by
Washington Ozaukee Public Health
License / ID
JLEY-DJKMZU
Status
Permitted
Official record
Washington Ozaukee Public Health inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20262204
20252171

Inspections

  1. Jan 30, 2026 Follow Up · 2 critical, 8 non-critical, 8 repeat
    • Not serious Non-critical Repeat

      SPARE STRAINER BASKET OR SCREEN AVAILABLE

      Spare strainer or screen not available

      Correction: Provide a spare strainer or screen

      Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN

    • Not serious Non-critical Repeat

      RECIRCULATION (TURNOVER) RATE NOT MET

      The recirculation (turnover) rate has not been met. The spa needs to turnover all water every half hour. To achieve this the spa needs about 60 GPM of flow though the recirculation system. The spa is currently reading 30 GPM of flow. The facility installed a new pump since the last inspection which may be why a decrease from 50 GPM was observed.

      Correction: Immediately adjust or replace equipment to operate at a proper turnover rate.

      Code ATCP 76.11(4)(c) - RECIRCULATION RATE

    • Not serious Non-critical Repeat

      FILTER MEDIA INSPECTED ANNUALLY

      Filter media is not being inspected annually or cleaned or replaced as necessary. Staff do not have any records of when the media was last replaced or inspected.

      Correction: Inspect the filters annually and clean and replace media as needed.

      Code ATCP 76.11(6)(a) 5. - FILTER MEDIA INSPECTED ANNUALLY

    • Not serious Non-critical Repeat

      ALKALINITY

      The total alkalinity is 330.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical Repeat

      TEST KIT APPROVED

      The facility is using a Pentair Rainbow Pool and Spa Test Kit for taking bromine reading in the spa. This type of kit does not meet the requirements of the code and is not approved by the department.

      Correction: The facility was previously using a Taylor K-2005 kit which is also not approved. If facility would like to still use a continuing to use a Taylor kit, use the K-2106 style kit for taking bromine readings. The K-2106 kit is a drop per drop bromine test using the R-0872 FAS-DPD titrating reagent for bromine combined with the R-0870 DPD powder. At the 25mL mark, each drop with the R-0872 liquid is 0

      Code ATCP 76.17 (1) - DEPARTMENT-APPROVED

    • Not serious Non-critical Repeat

      WHIRLPOOL, THERAPY POOL, EXERCISE POOL, ALKALINITY

      Spa water not tested at least once a week for total alkalinity.

      Correction: Test pool water at least once a week for total alkalinity.

      Code ATCP 76.18(2)(c) - ALKALINITY, WHIRL, EX, THERAPY

    • Not serious Non-critical Repeat

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Not serious Non-critical Repeat

      FILES RETAINED 2 YEARS-DAILY INSPECTIONS AND OPERATIONAL TESTS

      Daily inspection and operational tests records were being maintained in a locked room with a key that was not present in the facility during inspection. Health dept. had to wait on staff to arrive with the key.

      Correction: Maintain on premises for 2 years reports of daily inspections and operational tests. Keep these reports in a location that does not require special access.

      Code ATCP 76.32(3)(b)4. - DAILY INSPECTION AND OPERATIONAL TESTS

    • Serious Critical Corrected on site

      PH

      The pH is greater then 8.0.

      Correction: Maintain the pH at 7.2 to 7.8. Staff noted they ran out of acid which is the reason for the high pH. The spa needs to be closed until this hazard is corrected.

      Code ATCP 76.14(5)(c) - PH

    • Serious Critical Corrected on site

      CLOSING CRITERIA-FAILURE TO COMPLY WITH 76.14 OR PH LIMITS

      The Responsible Supervisor or operator has not closed the spa after failure to comply with pH limits.

      Correction: Close the spa in the event of failure to comply with pH values that are less than 6.8 or equal to or greater than 8.0. Upon health dept. order, the spa was closed and signage was posted during inspection.

      Code ATCP 76.30 (1)(c) - FAILURE TO COMPLY WITH ATCP 76.14

  2. Jan 16, 2026 Routine · 2 critical, 8 non-critical
    • Not serious Non-critical

      SPARE STRAINER BASKET OR SCREEN AVAILABLE

      Spare strainer or screen not available

      Correction: Provide a spare strainer or screen

      Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN

    • Not serious Non-critical

      RECIRCULATION (TURNOVER) RATE NOT MET

      The recirculation (turnover) rate has not been met. The spa needs to turnover all water every half hour. To achieve this the spa needs about 60 GPM of flow though the recirculation system. The spa is currently reading 30 GPM of flow. The facility installed a new pump since the last inspection which may be why a decrease from 50 GPM was observed.

      Correction: Immediately adjust or replace equipment to operate at a proper turnover rate.

      Code ATCP 76.11(4)(c) - RECIRCULATION RATE

    • Not serious Non-critical

      FILTER MEDIA INSPECTED ANNUALLY

      Filter media is not being inspected annually or cleaned or replaced as necessary. Staff do not have any records of when the media was last replaced or inspected.

      Correction: Inspect the filters annually and clean and replace media as needed.

      Code ATCP 76.11(6)(a) 5. - FILTER MEDIA INSPECTED ANNUALLY

    • Not serious Non-critical

      ALKALINITY

      The total alkalinity is 330.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical

      TEST KIT APPROVED

      The facility is using a Pentair Rainbow Pool and Spa Test Kit for taking bromine reading in the spa. This type of kit does not meet the requirements of the code and is not approved by the department.

      Correction: The facility was previously using a Taylor K-2005 kit which is also not approved. If facility would like to still use a continuing to use a Taylor kit, use the K-2106 style kit for taking bromine readings. The K-2106 kit is a drop per drop bromine test using the R-0872 FAS-DPD titrating reagent for bromine combined with the R-0870 DPD powder. At the 25mL mark, each drop with the R-0872 liquid is 0

      Code ATCP 76.17 (1) - DEPARTMENT-APPROVED

    • Not serious Non-critical

      WHIRLPOOL, THERAPY POOL, EXERCISE POOL, ALKALINITY

      Spa water not tested at least once a week for total alkalinity.

      Correction: Test pool water at least once a week for total alkalinity.

      Code ATCP 76.18(2)(c) - ALKALINITY, WHIRL, EX, THERAPY

    • Not serious Non-critical

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Not serious Non-critical

      FILES RETAINED 2 YEARS-DAILY INSPECTIONS AND OPERATIONAL TESTS

      Daily inspection and operational tests records were being maintained in a locked room with a key that was not present in the facility during inspection. Health dept. had to wait on staff to arrive with the key.

      Correction: Maintain on premises for 2 years reports of daily inspections and operational tests. Keep these reports in a location that does not require special access.

      Code ATCP 76.32(3)(b)4. - DAILY INSPECTION AND OPERATIONAL TESTS

    • Serious Critical

      PH

      The pH is greater then 8.0.

      Correction: Maintain the pH at 7.2 to 7.8. Staff noted they ran out of acid which is the reason for the high pH. The spa needs to be closed until this hazard is corrected.

      Code ATCP 76.14(5)(c) - PH

    • Serious Critical

      CLOSING CRITERIA-FAILURE TO COMPLY WITH 76.14 OR PH LIMITS

      The Responsible Supervisor or operator has not closed the spa after failure to comply with pH limits.

      Correction: Close the spa in the event of failure to comply with pH values that are less than 6.8 or equal to or greater than 8.0. Upon health dept. order, the spa was closed and signage was posted during inspection.

      Code ATCP 76.30 (1)(c) - FAILURE TO COMPLY WITH ATCP 76.14

  3. Jul 14, 2025 Pre-inspection · 1 critical, 8 non-critical
    • Not serious Non-critical

      SPARE STRAINER BASKET OR SCREEN AVAILABLE

      Spare strainer or screen not available

      Correction: Provide a spare strainer or screen

      Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN

    • Not serious Non-critical

      RECIRCULATION (TURNOVER) RATE NOT MET

      The recirculation (turnover) rate has not been met. The whirlpool needs a turnover rate of 30 minutes.

      Correction: Adjust or repair equipment to operate at a proper turnover rate. An additional 15 gallons of flow per minute are needed to reach the required rate.

      Code ATCP 76.11(4)(c) - RECIRCULATION RATE

    • Not serious Non-critical

      FILTER MEDIA INSPECTED ANNUALLY

      Filter media is not being inspected annually or cleaned or replaced as necessary. Staff do not have any records of when the media was last replaced or inspected.

      Correction: Inspect the filters annually and clean and replace media as needed.

      Code ATCP 76.11(6)(a) 5. - FILTER MEDIA INSPECTED ANNUALLY

    • Not serious Non-critical

      TEST KIT APPROVED

      The facility is using a Taylor K-2005 style test kit for taking bromine reading in the whirlpool. This type of kit does not meet the requirements of the code and is not approved by the department.

      Correction: If continuing to use a Taylor kit, use the K-2106 style kit for taking bromine readings. The K-2106 kit using a drop per drop bromine test using the R-0872 FAS-DPD titrating reagent for bromine combined with the R-0870 DPD powder. At the 25mL mark, each drop with the R-0872 liquid is 0.5PPM total bromine.

      Code ATCP 76.17 (1) - DEPARTMENT-APPROVED

    • Not serious Non-critical

      WHIRLPOOL, THERAPY POOL, EXERCISE POOL, ALKALINITY

      Whirlpool water not tested at least once a week for total alkalinity.

      Correction: Test pool water at least once a week for total alkalinity.

      Code ATCP 76.18(2)(c) - ALKALINITY, WHIRL, EX, THERAPY

    • Not serious Non-critical

      FIRST AID KIT ITEMS

      The first aid kit is present but missing items.

      Correction: Replace the missing items in the first aid kit.

      Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS

    • Not serious Non-critical

      EMERGENCY BLANKETS

      Two emergency blankets in good condition are not available.

      Correction: Provide two emergency blankets in good condition.

      Code ATCP 76.27(3) - EMERGENCY BLANKETS

    • Not serious Non-critical

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted.

      Correction: Provide signage warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Serious Critical

      TELEPHONE ACCESSIBLE

      The telephone for connecting to emergency services is not working.

      Correction: Provide a working telephone. The license to operate the spa can not be released until this hazard is corrected.

      Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE

  4. Jul 14, 2025 Pre-inspection Follow Up · 8 non-critical, 8 repeat
    • Not serious Non-critical Repeat

      SPARE STRAINER BASKET OR SCREEN AVAILABLE

      Spare strainer or screen not available

      Correction: Provide a spare strainer or screen

      Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN

    • Not serious Non-critical Repeat

      RECIRCULATION (TURNOVER) RATE NOT MET

      The recirculation (turnover) rate has not been met. The whirlpool needs a turnover rate of 30 minutes.

      Correction: Adjust or repair equipment to operate at a proper turnover rate. An additional 15 gallons of flow per minute are needed to reach the required rate.

      Code ATCP 76.11(4)(c) - RECIRCULATION RATE

    • Not serious Non-critical Repeat

      FILTER MEDIA INSPECTED ANNUALLY

      Filter media is not being inspected annually or cleaned or replaced as necessary. Staff do not have any records of when the media was last replaced or inspected.

      Correction: Inspect the filters annually and clean and replace media as needed.

      Code ATCP 76.11(6)(a) 5. - FILTER MEDIA INSPECTED ANNUALLY

    • Not serious Non-critical Repeat

      TEST KIT APPROVED

      The facility is using a Taylor K-2005 style test kit for taking bromine reading in the whirlpool. This type of kit does not meet the requirements of the code and is not approved by the department.

      Correction: If continuing to use a Taylor kit, use the K-2106 style kit for taking bromine readings. The K-2106 kit using a drop per drop bromine test using the R-0872 FAS-DPD titrating reagent for bromine combined with the R-0870 DPD powder. At the 25mL mark, each drop with the R-0872 liquid is 0.5PPM total bromine.

      Code ATCP 76.17 (1) - DEPARTMENT-APPROVED

    • Not serious Non-critical Repeat

      WHIRLPOOL, THERAPY POOL, EXERCISE POOL, ALKALINITY

      Whirlpool water not tested at least once a week for total alkalinity.

      Correction: Test pool water at least once a week for total alkalinity.

      Code ATCP 76.18(2)(c) - ALKALINITY, WHIRL, EX, THERAPY

    • Not serious Non-critical Repeat

      FIRST AID KIT ITEMS

      The first aid kit is present but missing items.

      Correction: Replace the missing items in the first aid kit.

      Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS

    • Not serious Non-critical Repeat

      EMERGENCY BLANKETS

      Two emergency blankets in good condition are not available.

      Correction: Provide two emergency blankets in good condition.

      Code ATCP 76.27(3) - EMERGENCY BLANKETS

    • Not serious Non-critical Repeat

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted.

      Correction: Provide signage warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

Source: Washington Ozaukee Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.