RecordWell Data

Esquire Estates Park Association

N111W16585 ESQUIRE CT, Germantown, WI 53022 · Washington County

19cited violations
6serious tier
6inspections

Establishment

Type
Pool / recreational water (Pool - Simple)
Inspected by
Washington Ozaukee Public Health
License / ID
PMUN-89LMCN
Status
Permitted
Phone
(414) 731-1124
Official record
Washington Ozaukee Public Health inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026385
2025140
2024161
2023110

Inspections

  1. Sep 4, 2026 Routine · 1 critical, 1 non-critical, 2 repeat
    • Not serious Non-critical Repeat

      CYANURATES 30 PPM LIMIT

      The cyanuric acid concentration is 100 PPM.

      Correction: Lower the water cyanuric acid concentration to 30 ppm or lower. Stop using stabilized chlorine to disinfect the pool

      Code ATCP 76.14(5)(b)1 - MAXIMUM CYANURIC

    • Serious Critical Repeat

      PATRONS RESTRICTED

      The facility is using a floating chlorine dispenser to dispense disinfectant directly into the pool basin.

      Correction: Disinfectant should be added via a feeder.

      Code ATCP 76.12(3)(c) - PATRONS EXCLUDED WHEN CHEMICALS ADDED TO

  2. Sep 4, 2026 Follow Up · 1 critical, 1 non-critical, 2 repeat
    • Not serious Non-critical Repeat

      CYANURATES 30 PPM LIMIT

      The cyanuric acid concentration is at 100 PPM.

      Correction: Lower the water cyanuric acid concentration to 30 ppm or lower.

      Code ATCP 76.14(5)(b)1 - MAXIMUM CYANURIC

    • Serious Critical Repeat Corrected on site

      PATRONS RESTRICTED

      During the routine inspection the facility was adding chlorine pucks to the strainer baskets in the pool basin and the facility was not restricting patrons from using the pool while this was occurring. During this follow up inspection, the facility was adding chlorine pucks to the pool by using a floater and was not restricting patrons from using the pool while this was occurring.

      Correction: Sanitarian reminded PIC that disinfectant needs be added via a feeder. The feeder was removed from the pool during the inspection.

      Code ATCP 76.12(3)(c) - PATRONS EXCLUDED WHEN CHEMICALS ADDED TO

  3. Jun 18, 2026 Routine · 3 critical, 1 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      CYANURATES 30 PPM LIMIT

      The cyanuric acid concentration is at 35 PPM.

      Correction: Lower the water cyanuric acid concentration to 30 ppm or lower.

      Code ATCP 76.14(5)(b)1 - MAXIMUM CYANURIC

    • Serious Critical

      PATRONS RESTRICTED

      The facility was adding chlorine pucks to the strainer baskets in the pool basin. The facility was not restricting patrons from using the pool while this was occurring.

      Correction: Disinfectant should be added via a feeder. The feeder was not properly functioning during the inspection and past few days which is why the PIC noted pucks were added to the strainer baskets. When chemicals are directly added to the pool basin the pool needs to be closed and posted.

      Code ATCP 76.12(3)(c) - PATRONS EXCLUDED WHEN CHEMICALS ADDED TO

    • Serious Critical

      MINIMUM DISINFECTANT RESIDUAL

      Minimum disinfectant level is 2.0 PPM of free chlorine for this pool. During the inspection, the facility was at 0.6 PPM of free chlorine.

      Correction: Sanitarian had PIC close the pool during the inspection.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

    • Serious Critical Corrected on site

      TELEPHONE ACCESSIBLE

      The facility uses cellular telecommunication technology to connect to emergency services. During the inspection, the phone was not connected to mains power and the sanitarian was not able to use the phone with backup battery.

      Correction: During the inspection, the cord to connect the phone to mains power was located and the phone was plugged in. The PIC then did test the phone and a successful test connecting the phone to emergency services was conducted.

      Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE

  4. Jun 19, 2025 Routine · 4 non-critical, 1 repeat
    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flowmeter is not being maintained in operating condition.

      Correction: Adjust or repair the flowmeter.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical

      CYANURATES 30 PPM LIMIT

      The cyanuric acid concentration is 50 PPM.

      Correction: Stop/reduce using Trichloro-S-Triazinetrione as the chlorine source. This chlorine product will continuously add cyanuric acid and in general it can only be removed via dilution by draining water.

      Code ATCP 76.14(5)(b)1 - MAXIMUM CYANURIC

    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

  5. Jun 21, 2024 Routine · 1 critical, 5 non-critical
    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      TEST KIT APPROVED

      The facility is using a test kit manufactured by Taylor that is the model K-2005. This model of test kit is not approved by the department.

      Correction: Replace the test kit with an approved test kit. Please contact the health dept. for a copy of this list. The only two Taylor approved kits at this time are model K-2106 and K-2006.

      Code ATCP 76.17 (1) - DEPARTMENT-APPROVED

    • Not serious Non-critical

      COMBINED CHLORINE TEST

      Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level.

      Correction: Test pool water at least twice a week for the combined chlorine level.

      Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,

    • Not serious Non-critical

      CYANURIC TEST

      Cyanuric acid is used in the pool basin and the cyanuric acid concentration is not tested at least once a week.

      Correction: Test water for the cyanuric acid at least once a week.

      Code ATCP 76.18(1)(d) - WATER TESTED CYANURIC

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-ATCP 76 CURRENT COPY

      A copy of the most current version of ch. ATCP 76 was not permanently maintained on premises.

      Correction: Maintain a copy of the most current version of ch. ATCP 76 on premises. Inspector is going to email a copy to the operator.

      Code ATCP 76.32(3)(a)1. - CURRENT ATCP 76 COPY

    • Serious Critical Corrected on site

      SHEPHERD'S CROOK PROVIDED

      The shepherd's crook was located in the pump room during the inspection and was unavailable for useage by patrons in case of emergency.

      Correction: Provide a shepherd's crook to the public. The crook was moved during inspection so the public could access.

      Code ATCP 76.26(1)(b)1.a. -SHEPHERED'S CROOK PROVIDED

  6. Jun 30, 2023 Routine · 1 non-critical
    • Not serious Non-critical

      FLOWMETER, VALVES AND GAUGES NOT FUNCTIONAL

      The flowmeter is not operating.

      Correction: Repair or replace the specified equipment so an accurate reading can be recorded.

      Code ATCP 76.11(5)

Source: Washington Ozaukee Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.