Esquire Estates Park Association
N111W16585 ESQUIRE CT, Germantown, WI 53022 · Washington County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- Washington Ozaukee Public Health
- License / ID
- PMUN-89LMCN
- Status
- Permitted
- Phone
- (414) 731-1124
- Official record
- Washington Ozaukee Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 3 | 8 | 5 |
| 2025 | 1 | 4 | 0 |
| 2024 | 1 | 6 | 1 |
| 2023 | 1 | 1 | 0 |
Inspections
-
Sep 4, 2026 Routine · 1 critical, 1 non-critical, 2 repeat
-
Not serious
Non-critical
Repeat
CYANURATES 30 PPM LIMIT
The cyanuric acid concentration is 100 PPM.
Correction: Lower the water cyanuric acid concentration to 30 ppm or lower. Stop using stabilized chlorine to disinfect the pool
Code ATCP 76.14(5)(b)1 - MAXIMUM CYANURIC
-
Serious
Critical
Repeat
PATRONS RESTRICTED
The facility is using a floating chlorine dispenser to dispense disinfectant directly into the pool basin.
Correction: Disinfectant should be added via a feeder.
Code ATCP 76.12(3)(c) - PATRONS EXCLUDED WHEN CHEMICALS ADDED TO
-
Not serious
Non-critical
Repeat
-
Sep 4, 2026 Follow Up · 1 critical, 1 non-critical, 2 repeat
-
Not serious
Non-critical
Repeat
CYANURATES 30 PPM LIMIT
The cyanuric acid concentration is at 100 PPM.
Correction: Lower the water cyanuric acid concentration to 30 ppm or lower.
Code ATCP 76.14(5)(b)1 - MAXIMUM CYANURIC
-
Serious
Critical
Repeat
Corrected on site
PATRONS RESTRICTED
During the routine inspection the facility was adding chlorine pucks to the strainer baskets in the pool basin and the facility was not restricting patrons from using the pool while this was occurring. During this follow up inspection, the facility was adding chlorine pucks to the pool by using a floater and was not restricting patrons from using the pool while this was occurring.
Correction: Sanitarian reminded PIC that disinfectant needs be added via a feeder. The feeder was removed from the pool during the inspection.
Code ATCP 76.12(3)(c) - PATRONS EXCLUDED WHEN CHEMICALS ADDED TO
-
Not serious
Non-critical
Repeat
-
Jun 18, 2026 Routine · 3 critical, 1 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
CYANURATES 30 PPM LIMIT
The cyanuric acid concentration is at 35 PPM.
Correction: Lower the water cyanuric acid concentration to 30 ppm or lower.
Code ATCP 76.14(5)(b)1 - MAXIMUM CYANURIC
-
Serious
Critical
PATRONS RESTRICTED
The facility was adding chlorine pucks to the strainer baskets in the pool basin. The facility was not restricting patrons from using the pool while this was occurring.
Correction: Disinfectant should be added via a feeder. The feeder was not properly functioning during the inspection and past few days which is why the PIC noted pucks were added to the strainer baskets. When chemicals are directly added to the pool basin the pool needs to be closed and posted.
Code ATCP 76.12(3)(c) - PATRONS EXCLUDED WHEN CHEMICALS ADDED TO
-
Serious
Critical
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant level is 2.0 PPM of free chlorine for this pool. During the inspection, the facility was at 0.6 PPM of free chlorine.
Correction: Sanitarian had PIC close the pool during the inspection.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
Corrected on site
TELEPHONE ACCESSIBLE
The facility uses cellular telecommunication technology to connect to emergency services. During the inspection, the phone was not connected to mains power and the sanitarian was not able to use the phone with backup battery.
Correction: During the inspection, the cord to connect the phone to mains power was located and the phone was plugged in. The PIC then did test the phone and a successful test connecting the phone to emergency services was conducted.
Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE
-
Not serious
Non-critical
Repeat
-
Jun 19, 2025 Routine · 4 non-critical, 1 repeat
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flowmeter is not being maintained in operating condition.
Correction: Adjust or repair the flowmeter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
CYANURATES 30 PPM LIMIT
The cyanuric acid concentration is 50 PPM.
Correction: Stop/reduce using Trichloro-S-Triazinetrione as the chlorine source. This chlorine product will continuously add cyanuric acid and in general it can only be removed via dilution by draining water.
Code ATCP 76.14(5)(b)1 - MAXIMUM CYANURIC
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
-
Jun 21, 2024 Routine · 1 critical, 5 non-critical
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
TEST KIT APPROVED
The facility is using a test kit manufactured by Taylor that is the model K-2005. This model of test kit is not approved by the department.
Correction: Replace the test kit with an approved test kit. Please contact the health dept. for a copy of this list. The only two Taylor approved kits at this time are model K-2106 and K-2006.
Code ATCP 76.17 (1) - DEPARTMENT-APPROVED
-
Not serious
Non-critical
COMBINED CHLORINE TEST
Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level.
Correction: Test pool water at least twice a week for the combined chlorine level.
Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,
-
Not serious
Non-critical
CYANURIC TEST
Cyanuric acid is used in the pool basin and the cyanuric acid concentration is not tested at least once a week.
Correction: Test water for the cyanuric acid at least once a week.
Code ATCP 76.18(1)(d) - WATER TESTED CYANURIC
-
Not serious
Non-critical
FILES MAINTAINED PERMANENT-ATCP 76 CURRENT COPY
A copy of the most current version of ch. ATCP 76 was not permanently maintained on premises.
Correction: Maintain a copy of the most current version of ch. ATCP 76 on premises. Inspector is going to email a copy to the operator.
Code ATCP 76.32(3)(a)1. - CURRENT ATCP 76 COPY
-
Serious
Critical
Corrected on site
SHEPHERD'S CROOK PROVIDED
The shepherd's crook was located in the pump room during the inspection and was unavailable for useage by patrons in case of emergency.
Correction: Provide a shepherd's crook to the public. The crook was moved during inspection so the public could access.
Code ATCP 76.26(1)(b)1.a. -SHEPHERED'S CROOK PROVIDED
-
Not serious
Non-critical
-
Jun 30, 2023 Routine · 1 non-critical
-
Not serious
Non-critical
FLOWMETER, VALVES AND GAUGES NOT FUNCTIONAL
The flowmeter is not operating.
Correction: Repair or replace the specified equipment so an accurate reading can be recorded.
Code ATCP 76.11(5)
-
Not serious
Non-critical
Source: Washington Ozaukee Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.