The Forge
2102 HWY 164, Richfield, WI 53076 · Washington County
Establishment
- Type
- Restaurant (retail food serving meals) (Retail Food - Serving Meals)
- Inspected by
- Washington Ozaukee Public Health
- License / ID
- JLEY-DSBLMB
- Status
- Permitted
- Official record
- Washington Ozaukee Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 3 | 9 | 9 |
Inspections
-
Oct 8, 2026 Follow Up · 3 priority, 3 repeat
-
Serious
Priority
Repeat
Corrected on site
TCS FOOD - COLD HOLDING
Routine: All food items located in the tabletop prep cooler on the main grill line were held at 50-51F. The unit was displaying a proper temperature on the display. Follow up: The cooler display noted 40F. An internal ambient air thermometer showed 44F. TCS pickles were at 40F. Sour cream was found to 49F.
Correction: Routine: Maintain cold time/temperature control for safety food at or below 41°F. The cooler internal thermometer may not be functional leading the warm unit to not turn on the compressor. Follow up: the cooler is not operating properly. The sour cream was discarded.
Code 3-501.16 (A) (2) AND (B)
-
Serious
Priority
Repeat
PLUMBING - BACKFLOW PREVENTION DEVICE - DESIGN STANDARD
The mop sink is missing backflow prevention devices. The sink should have an ASSE 1011 or ASSE 1052 along with a pressure bleed device (wasting tee) since the sink is connected to a ASSE 1055 chemical dispenser via a permanent hose connection.
Correction: Provide a State of Wisconsin approved backflow prevention device. View ASSE summary on 1055 devices.
Code 5-202.14
-
Serious
Priority
Repeat
PLUMBING - BACKFLOW PREVENTION DEVICE - WHEN REQUIRED
A beverage dispensing device (coffee) is plumbed into the water supply system and is not provided with a backflow prevention device.
Correction: Provide backflow prevention device. Plumbing systems shall be provided with backflow prevention at each point of use in the food establishment.
Code 5-203.14
-
Serious
Priority
Repeat
Corrected on site
-
Sep 28, 2026 Routine · 4 priority
-
Serious
Priority
TCS FOOD - COLD HOLDING
All food items located in the tabletop prep cooler on the main grill line were held at 50-51F. The unit was displaying a proper temperature on the display.
Correction: Maintain cold time/temperature control for safety food at or below 41°F. The cooler internal thermometer may not be functional leading the warm unit to not turn on the compressor.
Code 3-501.16 (A) (2) AND (B)
-
Serious
Priority
FOOD CONTACT SURFACES - WAREWASHING EQUIPMENT, CHEMICAL, TEMPERATURE, pH, CONCENTRATION AND HARDNESS
The facility has two dilution dispensers set up to dilute a lactic acid cleaner sanitizer. One of the dispensers (installed at the 3 comp sink) is not pulling any or only a negligable amount of product into the dilution. Test strips did not register a reading.
Correction: Repair or adjust warewashing equipment to provide proper sanitizer concentration.
Code 4-501.114 (A) - (E)
-
Serious
Priority
PLUMBING - BACKFLOW PREVENTION DEVICE - DESIGN STANDARD
The mop sink is missing backflow prevention devices. The sink should have an ASSE 1011 or ASSE 1052 along with a pressure bleed device (wasting tee) since the sink is connected to a ASSE 1055 chemical dispenser via a permanent hose connection.
Correction: Provide a State of Wisconsin approved backflow prevention device. View ASSE summary on 1055 devices.
Code 5-202.14
-
Serious
Priority
PLUMBING - BACKFLOW PREVENTION DEVICE - WHEN REQUIRED
A beverage dispensing device (coffee) is plumbed into the water supply system and is not provided with a backflow prevention device.
Correction: Provide backflow prevention device. Plumbing systems shall be provided with backflow prevention at each point of use in the food establishment.
Code 5-203.14
-
Serious
Priority
-
Mar 19, 2026 Pre-inspection · 2 priority
-
Serious
Priority
PLUMBING - BACKFLOW PREVENTION DEVICE - DESIGN STANDARD
The mop sink is missing backflow prevention devices. The sink should have an ASSE 1011 or ASSE 1052 along with a pressure bleed device (wasting tee) since the sink is connected to a ASSE 1055 chemical dispenser via a permanent hose connection.
Correction: Provide a State of Wisconsin approved backflow prevention device. View ASSE summary on 1055 devices.
Code 5-202.14
-
Serious
Priority
PLUMBING - BACKFLOW PREVENTION DEVICE - WHEN REQUIRED
A beverage dispensing device the is plumbed into the water supply system is not provided with a backflow prevention device.
Correction: Provide backflow prevention device. Plumbing systems shall be provided with backflow prevention at each point of use in the food establishment.
Code 5-203.14
-
Serious
Priority
Source: Washington Ozaukee Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.