Comfort Inn And Suites - Pool

W177N9675 RIVERSBEND LN, Germantown, WI 53022 · Washington County

20cited violations
3serious tier
4inspections

Establishment

Type
Pool / recreational water (Pool - Simple)
Inspected by
Washington Ozaukee Public Health
License / ID
HSAT-7QXE2T
Status
Permitted
Phone
(262) 255-1100
Official record
Washington Ozaukee Public Health inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026173
20242130
2023100

Inspections

  1. May 6, 2026 Routine · 3 critical, 4 non-critical, 3 repeat
    • Not serious Non-critical Repeat

      INTERLOCK-LOG KEPT

      There was no proof that a log of the monthly interlock tests is being kept.

      Correction: Keep a log of monthly interlock tests. It is possible the log is being kept in a locked office that no staff present have access to. Please see ATCP 76.13 (1)(c) 4. b.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

    • Not serious Non-critical Repeat

      REAGENTS REPLACED

      Test kit reagents are not replaced as recommended by the manufacturer. The reagents are expired.

      Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Not serious Non-critical Repeat

      FILES RETAINED 2 YEARS-DAILY INSPECTIONS AND OPERATIONAL TESTS

      Daily inspection and operational tests records were being stored in a locked office that no staff present had access to.

      Correction: Maintain on premises for 2 years reports of daily inspections and operational tests.

      Code ATCP 76.32(3)(b)4. - DAILY INSPECTION AND OPERATIONAL TESTS

    • Not serious Non-critical

      POOL BASIN MAINTAINED FREE OF DEFECTS

      The pool basin is not being maintained. The wall in the basin that separates the pool from the spa has cracks and other defects along with missing basin tiles.

      Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition.

      Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR

    • Serious Critical Corrected on site

      CHEMICAL STORAGE LOCATION

      The pool chemicals were being stored in an equipment room that was not locked. When the inspection stated the door was not even latched.

      Correction: Store all chemicals in a locked area. To help insure safety, the sanitarian locked the equipment room door upon ending the inspection. Make sure this door stays latched and locked going forward.

      Code ATCP 76.12 (2)(b) - CHEMICAL STORAGE LOCATION

    • Serious Critical

      HAZARDOUS CONDITION

      The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation were not present in for inspection. The facility has been unable to provide proof of compliance with the Virginia Graeme Baker Act since 2019. Based on a phone conservation with Julie Kugler, the facility has obtained the proof of installation date paperwork, however, this paperwork was locked in an office and no staff present could access it.

      Correction: Provide proof of compliance with the Virginia Graeme Baker Act to the health dept. If not provided or the main drain and equalizer covers are not found in compliance with the Virginia Graeme Baker Act the sanitarian will follow REC-POL-014 VGBA Enforcement Policy.

      Code ATCP 76.34(1) - HAZARDOUS CONDITION AT POOL AREA

    • Serious Critical

      GATES AND DOORS-LATCHING

      The gate or door does not latch. Tape is being used to keep the latch forced open.

      Correction: Provide a latching door. A call with Julie Kugler indicated that the door needs to be repaired. The pool needs to be closed until the latch is repaired. See ATCP 76.30 (1)(i).

      Code ATCP 76.34(4)(a)(1m)(b)- LATCHING

  2. Dec 3, 2024 Routine · 9 non-critical, 4 repeat
    • Not serious Non-critical

      SKIMMERS MAINTAINED CLEAN

      Skimmers were not clean. Excessive debris such as multiple plastic cups was found.

      Correction: Maintain the skimmers in clean condition.

      Code ATCP 76.11(2)(b) 1. - SKIMMERS CLEAN

    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flowmeter is not being maintained in operating condition.

      Correction: Adjust or repair the flowmeter.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical Repeat

      INTERLOCK-LOG KEPT

      A log of the monthly interlock tests is not being kept.

      Correction: Keep a log of monthly interlock tests. This can easily be accomplished by marking a check box on the pump safety area of the pool log.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

    • Not serious Non-critical

      ALKALINITY

      The total alkalinity is 20 ppm.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical

      REAGENTS REPLACED

      The facility is using a test kit that is expired.

      Correction: Upon bringing this up to the supervisor, it was determined that the facility has a new test kit in storage. Staff went to obtain the new kit, but found it was a chlorine test kit (K-2006). Since this pool is using bromine, staff noted they are going to exchange the kit with a new bromine kit (K-2106). After the bromine kit is obtained, staff noted they will discard the old kit.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Not serious Non-critical Repeat

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage against prolonged breath-holding is not posted. Since this pool is not lifeguarded, there is no other way to communicate to patrons.

      Correction: Provide signage warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Not serious Non-critical

      OPERATING REPORTS-CHEMICAL TESTING

      The operator did not record the following on the operating report: Results for chemical testing. While the facility had the updated pool logs on site for November and December, the logs were improperly filled out, missing data, and not present for each day.

      Correction: Record the following on the operating report, results for chemical testing.

      Code ATCP 76.32(1)(a) - CHEMICAL TESTING

    • Not serious Non-critical Repeat

      FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION

      The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises.

      Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises. If the facility is unable to provide proof of the age of these drains and equalizer covers by the next routine inspection, the department may require replacement and close the pool until replacement occurs.

      Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER

    • Not serious Non-critical Repeat

      FILES RETAINED 2 YEARS-DAILY INSPECTIONS AND OPERATIONAL TESTS

      Daily inspection and operational tests records not maintained on premises for 2 years. Staff note they send these to the corporate office after the month they are used.

      Correction: Maintain on premises for 2 years reports of daily inspections and operational tests. Inspector suggests sending a photocopy of the reports to the corporate office and keeping the original reports on premises.

      Code ATCP 76.32(3)(b)4. - DAILY INSPECTION AND OPERATIONAL TESTS

  3. Jun 27, 2024 Routine · 4 non-critical
    • Not serious Non-critical

      INTERLOCK-LOG KEPT

      A log of the monthly interlock challenge tests is not being kept.

      Correction: Keep a log of monthly interlock tests. This will be easier when the facility transitions to new logs that have a slot for marking challenge tests.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

    • Not serious Non-critical

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION

      The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises.

      Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises. If the facility is unable to provide proof of the age of these drains and equalizer covers, the department may require replacement.

      Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER

    • Not serious Non-critical

      FILES RETAINED 2 YEARS-DAILY INSPECTIONS AND OPERATIONAL TESTS

      Daily inspection and operational tests records were not maintained on premises for 2 years. Many of the records had been removed from the facility for a business meeting. As such, the inspector was unable to review these files.

      Correction: Maintain on premises for 2 years reports of daily inspections and operational tests.

      Code ATCP 76.32(3)(b)4. - DAILY INSPECTION AND OPERATIONAL TESTS

  4. Jun 28, 2023 Routine · No items found

    No violations cited.