RecordWell Data

Overstone Condominium Association

19960 OVERSTONE DR, Lannon, WI 53046 · Waukesha County

4cited violations
2serious tier
4inspections

Establishment

Type
Pool / recreational water (Pool - Simple)
Inspected by
Waukesha County Environmental Health
License / ID
HDEH-C3DG4Q
Status
Permitted
Phone
(262) 238-1480
Official record
Waukesha County Environmental Health inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026132
2025110
2024100
2023100

Inspections

  1. Aug 3, 2026 Routine · 2 critical, 1 non-critical
    • Not serious Non-critical

      POOL RULES LETTER OR SYMBOL SIZE

      Pool rule letters are less than 1 inch in size. Per the person-in-charge, the rule sign is new this season.

      Correction: Correct the size of the letters or symbols, so that letters are at least one inch in height and symbols are at least 4 inches in height.

      Code ATCP 76.29(1)(a)2. -LETTER OR SYMBOL SIZE

    • Serious Critical

      MINIMUM DISINFECTANT RESIDUAL

      Free Chlorine level is less than 1.0 PPM. Two tests were ran. Pool was closed and patrons were told to get out of the pool. ORP was adjusted up to 810 mV from 770 mV. Free Chlorine re-tested to 2.04 PPM. Corrected. Patrons were allowed back into the pool. Corrected.

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

    • Serious Critical

      CO ALARM-POOL EQUIPMENT ROOM

      There is a fuel-burning device in the equipment room but no Carbon Monoxide alarm in the equipment room.

      Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.

      Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM

  2. Jul 2, 2025 Routine · 1 non-critical
    • Not serious Non-critical

      OPERATING REPORTS-INTERLOCK TESTING

      The operator did not record the following on the operating report: Dates of interlock tests, results and comments. Pool operators have been checking it 4-5 times per month when they turn off the power for servicing the strainer basket. Discussed with the operators of documenting the interlock check dates and results on the chemical form going forward.

      Correction: Record the following on the operating report, dates of interlock tests, results and comments.

      Code ATCP 76.32(1)(d) - INTERLOCK TEST

  3. Aug 5, 2024 Routine · No items found

    No violations cited.

  4. Jul 20, 2023 Routine · No items found

    No violations cited.