RecordWell Data

Towneplace Suites By Marriott

600 N CALHOUN RD, Brookfield, WI 53005 · Waukesha County

24cited violations
10serious tier
8inspections

Establishment

Type
Pool / recreational water (Pool - Simple)
Inspected by
Waukesha County Environmental Health
License / ID
HDEH-A78KE8
Status
Permitted
Phone
(262) 784-8450
Official record
Waukesha County Environmental Health inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026474
20253146
2023130

Inspections

  1. Aug 26, 2026 Re-inspection · 1 critical, 3 non-critical
    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flowmeter is not being maintained in operating condition. Observed with no pressure reading.

      Correction: Adjust or repair the flow meter.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical

      OPERATING REPORTS-CHEMICAL TESTING

      The operator did not record the following on the operating report: Results for chemical testing for every day the pool is open for use.

      Correction: Record the following on the operating report, results for chemical testing every day the pool is open for use.

      Code ATCP 76.32(1)(a) - CHEMICAL TESTING

    • Not serious Non-critical

      DRINKING FOUNTAIN MAINTAINED

      The drinking fountain is not in working condition and able to provide water during inspection. Facility maintinance stated water may not be turned on and they need to access the room located on the other side of the wall to make adjustment. Room is currenlty in service and unable to turn on during inspection. Facility GM stated water will be turned on when room service is able to service the room.

      Correction: Maintain the drinking fountain in clean and sanitary condition.

      Code ATCP 76.33(1)(g)2.-DRINKING FOUNTAIN CLEAN

    • Serious Critical Corrected on site

      INTERLOCK LOG-INFORMATION

      The monthly testing log is missing or incomplete. CORRECTED Education was provided and facility shall complete logs indicating monthly interlock testing is being completed.

      Correction: Maintain a log that is documented with the date, results, and the name of the person performing the interlock test.

      Code ATCP 76.13 (1)(c)4.a - INTERLOCK LOG, INFORMATION REQUIRED

  2. Aug 25, 2026 Re-inspection 2 · 1 critical, 1 repeat
    • Serious Critical Repeat

      MINIMUM DISINFECTANT RESIDUAL

      Minimum disinfectant or sanitizer level is 0ppm for chlorine. Pool was closed at time of inspection and shall remain closed until free chlorine levels can be maintained above 1ppm.

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

  3. Aug 21, 2026 Re-inspection · 1 critical
    • Serious Critical

      MINIMUM DISINFECTANT RESIDUAL

      Minimum disinfectant or sanitizer level is between 25ppm and 50ppm for chlorine. Pool was closed at time of inspection and shall remain closed until free chlorine levels can be maintained above 1ppm.

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

  4. Aug 20, 2026 Routine · 1 critical
    • Serious Critical

      MINIMUM DISINFECTANT RESIDUAL

      Minimum disinfectant or sanitizer level is 0 for liquid chlorine. Pool was closed at time of inspection and shall remain closed until free chlorine levels can be maintained above 1ppm.

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

  5. Jul 25, 2025 Follow Up · 2 critical, 2 repeat
    • Serious Critical Repeat Corrected on site

      CHEMICAL STORAGE, SEPARATION OF OXIDIZERS AND ACIDS

      Chlorine is not stored separately from acid. CORRECTED chemicals voluntarily rearranged during inspection.

      Correction: Store oxidizers separately from acids.

      Code ATCP 76.12 (2)(c) - CHEMICAL SEPARATION OXIDIZERS, ACIDS

    • Serious Critical Repeat Corrected on site

      OPERATOR KNOWLEDGE-MONTHLY TESTING

      The person responsible is not able to describe how monthly testing is performed. CORRECTED education was provided and new logs shall be sent with this report.

      Correction: Ensure that operator can describe how monthly testing is performed.

      Code ATCP 76.13 (1)(c)2.d - MONTHLY TESTING

  6. Jul 17, 2025 Follow Up · 2 critical, 4 non-critical, 6 repeat
    • Not serious Non-critical Repeat

      REAGENTS REPLACED

      Test kit reagents not replaced as recommended by the manufacturer. Observed expired reagents during inspection.

      Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Not serious Non-critical Repeat

      EMERGENCY BLANKETS

      Two emergency blankets in good condition are not available in the pool area.

      Correction: Provide two emergency blankets in good condition in the pool area.

      Code ATCP 76.27(3) - EMERGENCY BLANKETS

    • Not serious Non-critical Repeat

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Not serious Non-critical Repeat

      FILES RETAINED 2 YEARS-ANY OTHER REPORTS REQUIRED

      During inspection, pool operator was not available and peraon in charge was unable to locate files with required reports.

      Correction: Maintain on premises for 2 years any reports required by the department or its agent.

      Code ATCP 76.32(3)(b)5. - OTHER REPORT REQUIRED

    • Serious Critical Repeat Corrected on site

      CHEMICAL STORAGE, SEPARATION OF OXIDIZERS AND ACIDS

      Chlorine is not stored separately from acid. CORRECTED chemicals voluntarily rearranged during inspection.

      Correction: Store oxidizers separately from acids.

      Code ATCP 76.12 (2)(c) - CHEMICAL SEPARATION OXIDIZERS, ACIDS

    • Serious Critical Repeat Corrected on site

      OPERATOR KNOWLEDGE-MONTHLY TESTING

      The person responsible is not able to describe how monthly testing is performed. CORRECTED education was provided and new logs shall be sent with this report.

      Correction: Ensure that operator can describe how monthly testing is performed.

      Code ATCP 76.13 (1)(c)2.d - MONTHLY TESTING

  7. Jul 10, 2025 Routine · 2 critical, 4 non-critical
    • Not serious Non-critical

      REAGENTS REPLACED

      Test kit reagents not replaced as recommended by the manufacturer. Observed expired reagents during inspection.

      Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Not serious Non-critical

      EMERGENCY BLANKETS

      Two emergency blankets in good condition are not available in the pool area.

      Correction: Provide two emergency blankets in good condition in the pool area.

      Code ATCP 76.27(3) - EMERGENCY BLANKETS

    • Not serious Non-critical

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Not serious Non-critical

      FILES RETAINED 2 YEARS-ANY OTHER REPORTS REQUIRED

      During inspection, pool operator was not available and peraon in charge was unable to locate files with required reports.

      Correction: Maintain on premises for 2 years any reports required by the department or its agent.

      Code ATCP 76.32(3)(b)5. - OTHER REPORT REQUIRED

    • Serious Critical Corrected on site

      CHEMICAL STORAGE, SEPARATION OF OXIDIZERS AND ACIDS

      Chlorine is not stored separately from acid. CORRECTED chemicals voluntarily rearranged during inspection.

      Correction: Store oxidizers separately from acids.

      Code ATCP 76.12 (2)(c) - CHEMICAL SEPARATION OXIDIZERS, ACIDS

    • Serious Critical Corrected on site

      OPERATOR KNOWLEDGE-MONTHLY TESTING

      The person responsible is not able to describe how monthly testing is performed. CORRECTED education was provided and new logs shall be sent with this report.

      Correction: Ensure that operator can describe how monthly testing is performed.

      Code ATCP 76.13 (1)(c)2.d - MONTHLY TESTING

  8. Aug 10, 2023 Routine · 3 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      FLOWMETER, VALVES AND GAUGES NOT FUNCTIONAL

      The flowmeter is not operational.

      Correction: Repair or replace the specified equipment so an accurate reading can be recorded.

      Code ATCP 76.11(5)

    • Not serious Non-critical

      WATER TESTING FREQUENCY - POOLS

      The water testing frequency for combined chlorine is not in compliance with ATCP 76.18(1). Water testing has not been documented since 8/7/2023. Several days each month are not documented. Discussed that if the pool is closed on a particular day to indicate it on the chemical sheet. However, if the pool is open, then chemical recordings are required to be documented.

      Correction: Perform water testing in accordance with ATCP 76.18(1).

      Code ATCP 76.18(1)

    • Not serious Non-critical

      SKIMMER BASKET OR WEIR MISSING

      The weir door is missing on the skimmer closes to the gate.

      Correction: Replace the missing equipment.

      Code [B] ATCP 76.11(2)(b)

Source: Waukesha County Environmental Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.