Home2suites-whirlpool
650 LARRY CT, Waukesha, WI 53186 · Waukesha County
Establishment
- Type
- Pool / recreational water (Pool - Moderate)
- Inspected by
- Waukesha County Environmental Health
- License / ID
- TQUT-AGCRXF
- Status
- Permitted
- Official record
- Waukesha County Environmental Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 2 | 8 | 0 |
| 2025 | 2 | 9 | 5 |
| 2023 | 5 | 13 | 1 |
Inspections
-
Aug 3, 2026 Re-inspection · 3 non-critical, 2 repeat
-
Not serious
Non-critical
SKIMMERS-ADJUSTED
Skimmers not adjusted to ensure vigorous skimming. No water flow through skimmer.
Correction: Adjust skimmers to maintain vigorous skimming .
Code ATCP 76.11(2)(a) 1. - SKIMMERS ADJUSTED
-
Not serious
Non-critical
Repeat
OPERATING REPORTS-CHEMICAL TESTING
The operator did not record the following on the operating report: Results for chemical testing on weekends.
Correction: Record the following on the operating report, results for chemical testing every day the pool is open.
Code ATCP 76.32(1)(a) - CHEMICAL TESTING
-
Not serious
Non-critical
Repeat
POOL EQUIPMENT-REPAIRED AS NECESSARY
The pool equipment is not repaired as necessary. Left hand rail for the spa entry is loose.
Correction: Repair the left hand rail on the spa entry.
Code ATCP 76.33(1)(e)4. - EQPT REPAIRED AS NEEDED
-
Not serious
Non-critical
-
May 1, 2026 Routine · 5 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Skimmer weir not repaired or replaced as neded.
Correction: Replace weirs as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool. The combined chlorine level observed at 2 PPM.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
OPERATING REPORTS-CHEMICAL TESTING
The operator did not record the following on the operating report: Results for chemical testing on weekends.
Correction: Record the following on the operating report, results for chemical testing every day the pool is open.
Code ATCP 76.32(1)(a) - CHEMICAL TESTING
-
Not serious
Non-critical
POOL EQUIPMENT-REPAIRED AS NECESSARY
The pool equipment is not repaired as necessary. Left hand rail for the spa entry is loose.
Correction: Repair the left hand rail on the spa entry.
Code ATCP 76.33(1)(e)4. - EQPT REPAIRED AS NEEDED
-
Not serious
Non-critical
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement. Operator states the drain cover was installed 2023 but will find the necessary paper work.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Not serious
Non-critical
Repeat
-
May 2, 2025 Re-inspection · 2 critical, 1 repeat
-
Serious
Critical
Corrected on site
PH
The pH is 8.3. 5/2/25: pH is 7.9. The controller reads pH 7.76. This falls within critical limit. Acid is feeding during inspection.
Correction: Maintain the pH at 7.2 to 7.8.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
Repeat
VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO
The operator of an existing pool does not have the pump curve or drain cover specifications.
Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.
Code ATCP 76.38(1)(b) - PUMP CURVE
-
Serious
Critical
Corrected on site
-
Apr 29, 2025 Routine · 3 critical, 4 non-critical, 2 repeat
-
Not serious
Non-critical
Repeat
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Skimmer weir is missing.
Correction: Repair or replace weirs as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 235 PPM.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is 230 mV and water has not been tested manually.
Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Not serious
Non-critical
ELECTRONIC MONITORING FREQUENCY OF TESTING
The pool, with an electronic monitoring device, has not been manually tested at least once a day with an approved test kit for pH and disinfectant or sanitizer residual.
Correction: Manually test the pool at least once a day for pH and disinfectant or sanitizer residual with an approved test kit.
Code ATCP 76.18(3)(a) - ELECTRONIC MONITORING TEST FREQ
-
Serious
Critical
MINIMUM DISINFECTANT RESIDUAL
The free chlorine concentration is 0.23 PPM (LDL).
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A (3 PPM).
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
Repeat
PH
The pH is 8.3.
Correction: Maintain the pH at 7.2 to 7.8.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO
The operator of an existing pool does not have the pump curve or drain cover specifications.
Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.
Code ATCP 76.38(1)(b) - PUMP CURVE
-
Not serious
Non-critical
Repeat
-
Dec 27, 2023 Re-inspection · 2 non-critical, 2 repeat
-
Not serious
Non-critical
Repeat
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Skimmers not repaired or replaced as needed. Skimmer weir is missing.
Correction: Repair or replace skimmer, weirs or gutters as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
Repeat
WHIRLPOOLS-RULES, MINORS UNDER AGE 6
Signage for whirlpool is missing this rule: Minors under the age of 6 are not permitted in the whirlpool.
Correction: Include rule stating: Minors under the age of 6 are not permitted in the whirlpool.
Code ATCP 76.29(3)(e) - NO CHILDREN UNDER 6
-
Not serious
Non-critical
Repeat
-
Sep 28, 2023 Re-inspection · 3 non-critical, 3 repeat
-
Not serious
Non-critical
Repeat
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Skimmers not repaired or replaced as needed. Skimmer weir is missing.
Correction: Repair or replace skimmer, weirs or gutters as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
Repeat
CERTIFIED OPERATOR REQUIRED AFTER 2 OR MORE REINSPECTIONS IN 3 YEARS
A pool that is required to have a certified operator does not have one.
Correction: Provide a certified operator for the pool.
Code ATCP 76.20(2)(a)2 - CERTIFIED OPERATOR REQUIRED, REINSPECTIO
-
Not serious
Non-critical
Repeat
WHIRLPOOLS-RULES, MINORS UNDER AGE 6
Signage for whirlpool is missing this rule: Minors under the age of 6 are not permitted in the whirlpool.
Correction: Include rule stating: Minors under the age of 6 are not permitted in the whirlpool.
Code ATCP 76.29(3)(e) - NO CHILDREN UNDER 6
-
Not serious
Non-critical
Repeat
-
Sep 27, 2023 Routine · 1 critical, 3 non-critical
-
Not serious
Non-critical
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Skimmers not repaired or replaced as needed. Skimmer weir is missing.
Correction: Repair or replace skimmer, weirs or gutters as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
CERTIFIED OPERATOR REQUIRED AFTER 2 OR MORE REINSPECTIONS IN 3 YEARS
A pool that is required to have a certified operator does not have one.
Correction: Provide a certified operator for the pool.
Code ATCP 76.20(2)(a)2 - CERTIFIED OPERATOR REQUIRED, REINSPECTIO
-
Not serious
Non-critical
WHIRLPOOLS-RULES, MINORS UNDER AGE 6
Signage for whirlpool is missing this rule: Minors under the age of 6 are not permitted in the whirlpool.
Correction: Include rule stating: Minors under the age of 6 are not permitted in the whirlpool.
Code ATCP 76.29(3)(e) - NO CHILDREN UNDER 6
-
Serious
Critical
PH
The pH is >8.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Not serious
Non-critical
-
Sep 12, 2023 Follow Up · No items found
No violations cited.
-
Sep 5, 2023 Re-inspection · 4 non-critical, 2 repeat
-
Not serious
Non-critical
pH OUT OF BALANCE
The pH is 8.1.
Correction: Close the pool and do not reopen it until the pH falls between 7.2 and 7.8.
Code ATCP 76.14(4)(c)
-
Not serious
Non-critical
ALKALINITY OUT OF BALANCE
The total alkalinity is 33 ppm.
Correction: Maintain the total alkalinity between 60 and 180 ppm.
Code ATCP 76.14(4)(d)
-
Not serious
Non-critical
Repeat
CHLORINE TOO HIGH
The chlorine residual exceeded 10 ppm.
Correction: The pool must be closed and may not reopen until the chlorine residual comes into an acceptable range.
Code ATCP 76.14(4)(f)
-
Not serious
Non-critical
Repeat
MONTHLY OPERATION REPORTS NOT SUBMITTED
Monthly operation reports are not being kept in accordance with ATCP 76.32(1). Weeks missing of daily logs.
Correction: Keep monthly operation reports in accordance with ATCP 76.32(1).
Code [A] ATCP 76.32(1)
-
Not serious
Non-critical
Source: Waukesha County Environmental Health. History last read Nov 21, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.