RecordWell Data

Springhill Suites

N91W15901 FALLS PKWY, Menomonee Falls, WI 53051 · Waukesha County

16cited violations
5serious tier
4inspections

Establishment

Type
Pool / recreational water (Pool - Simple)
Inspected by
Waukesha County Environmental Health
License / ID
HDEH-CURF5F
Status
Permitted
Phone
(262) 509-9100
Official record
Waukesha County Environmental Health inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026173
2025130
2023262

Inspections

  1. Jul 1, 2026 Routine · 3 critical, 4 non-critical, 2 repeat
    • Not serious Non-critical Repeat

      SKIMMERS REPAIRED OR REPLACED AS NEEDED

      The weir door is missing and has not been replaced as needed. This is a repeat violation. It was documented during the last inspection and again today. This violation shall be corrected prior to the next routine inspection. Failure to correct the violation will result in a reinspection as established in our reinspection criteria. The Waukesha County Code of Ordinances requires a reinspection fee to be assessed for any reinspection. Our department is available as a resource to provide suggestions and guidance on how to correct the violation.

      Correction: Repair or replace skimmer, weirs or gutters as needed.

      Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED

    • Not serious Non-critical

      SPARE STRAINER BASKET OR SCREEN AVAILABLE

      Spare strainer basket for the pump is not available

      Correction: Provide a spare strainer or screen

      Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN

    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical Repeat

      OPERATING REPORTS-CHEMICAL TESTING

      The operator did not record the following on the operating report: results for chemical testing. Daily testing logs for May and June of 2026 are unavailable for review. This is a repeat violation. It was documented during the last inspection and again today. This violation shall be corrected prior to the next routine inspection. Failure to correct the violation will result in a reinspection as established in our reinspection criteria. The Waukesha County Code of Ordinances requires a reinspection fee to be assessed for any reinspection. Our department is available as a resource to provide suggestions and guidance on how to correct the violation.

      Correction: Record the following on the operating report, results for chemical testing.

      Code ATCP 76.32(1)(a) - CHEMICAL TESTING

    • Serious Critical Corrected on site

      PH

      The pH is 8.0. The pool operator recalibrated the controller and the system began feeding acid during the inspection. The pH reached 7.6 during the inspection.

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

    • Serious Critical Corrected on site

      RING BOUY

      A ring buoy not provided with long enough rope. The pool operator removed the ring bouy from the pool enclosure.

      Correction: Provide a ring buoy with rope a length not less than 1-1/2 times the maximum width of the pool or 50 feet, whichever is less.

      Code ATCP 76.26(1)(b)2.a - RING BOUY

    • Serious Critical Corrected on site

      CO ALARM-POOL EQUIPMENT ROOM

      There is a fuel-burning device in the pump room but no CO alarm in the pump room. The pool operator provided a CO alarm in the pump room during the inspection.

      Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.

      Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM

  2. Mar 28, 2025 Routine · 3 non-critical
    • Not serious Non-critical

      SKIMMERS REPAIRED OR REPLACED AS NEEDED

      There is no weir present in the skimmer.

      Correction: Repair or replace skimmer, weirs or gutters as needed.

      Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED

    • Not serious Non-critical

      OPERATING REPORTS-CHEMICAL TESTING

      The operator did not record the following on the operating report: Results for chemical testing daily.

      Correction: Record the following on the operating report, results for chemical testing.

      Code ATCP 76.32(1)(a) - CHEMICAL TESTING

    • Not serious Non-critical

      OPERATING REPORTS-INTERLOCK TESTING

      The operator did not record the following on the operating report: Dates of interlock tests, results and comments.

      Correction: Record the following on the operating report, dates of interlock tests, results and comments.

      Code ATCP 76.32(1)(d) - INTERLOCK TEST

  3. Oct 16, 2023 Re-inspection · No items found

    No violations cited.

  4. Oct 10, 2023 Pre-inspection · 2 critical, 4 non-critical
    • Not serious Non-critical

      TELEPHONE-EMERGENCY NUMBERS AND ADDRESS

      A list of emergency numbers and facility address not attached or posted near telephone.

      Correction: Provide a list of emergency numbers and facility address, attached or posted near telephone or other telecommunication technology device.

      Code ATCP 76.26(2)(d) - TELEPHONE, EMERGENCY NUMBERS POSTED

    • Not serious Non-critical

      POSTING SIGNAGE-SUPERVISION OF CHILDREN

      At a non-lifeguarded pool, no signage stating that children under 12 must be supervised is present.

      Correction: Post signage stating that children under 12 must be supervised.

      Code ATCP 76.29(1)(c) - SUPERVISE CHILDREN

    • Not serious Non-critical

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Not serious Non-critical

      POOL DECK-GOOD REPAIR

      The grout filled in by depth tile near the entrance was not flush with the tile and may cause injury.

      Correction: Maintain pool deck area in good repair

      Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR

    • Serious Critical

      PH

      The pH is above 8.

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

    • Serious Critical

      TELEPHONE ACCESSIBLE

      The telephone in the pool area currently connects with the front desk instead of have a dial tone so emergency services can be contacted directly.

      Correction: Provide a working telephone or other technology capable of connecting with emergency services.

      Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE

Source: Waukesha County Environmental Health. History last read Nov 21, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.