Home2suites-pool
650 LARRY CT, Waukesha, WI 53186 · Waukesha County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- Waukesha County Environmental Health
- License / ID
- HDEH-AG7U3M
- Status
- Permitted
- Official record
- Waukesha County Environmental Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 2 | 7 | 1 |
| 2025 | 4 | 24 | 12 |
| 2023 | 2 | 7 | 3 |
Inspections
-
May 8, 2026 Re-inspection · 1 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
POOL RULES POSTED
The pool rules are not posted to requirements of size and wording.
Correction: Post the pool rules.
Code ATCP 76.29(1)(a)1. - SIGNAGE POSTED
-
Not serious
Non-critical
Repeat
-
May 1, 2026 Routine · 1 critical, 5 non-critical, 2 repeat
-
Not serious
Non-critical
Repeat
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Skimmer weirs not repaired or replaced as needed.
Correction: Repair or replace skimmer weirs.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept.
Correction: Keep a log of monthly interlock tests.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
AUTOMATED PRIMARY DISINFECTION
The primary disinfection, liquid chlorine, is not connected to the recirculation system.
Correction: Provide primary disinfection system capable of chlorinating when secondary system is not maintaining required disinfection residuals.
Code ATCP 76.15 WITH SUPPLEMENATL SYSTEMS, PRIMARY DISINFECTION R
-
Not serious
Non-critical
POOL RULES POSTED
The pool rules are not posted to requirements of size and wording.
Correction: Post the pool rules.
Code ATCP 76.29(1)(a)1. - SIGNAGE POSTED
-
Not serious
Non-critical
OPERATING REPORTS-CHEMICAL TESTING
The operator did not record the following on the operating report: Results for chemical testing on weekends.
Correction: Record the following on the operating report, results for chemical testing every day the pool is open.
Code ATCP 76.32(1)(a) - CHEMICAL TESTING
-
Serious
Critical
Repeat
Corrected on site
HAZARDOUS CONDITION
There is a hazardous condition at the pool. Main drain cover missing fasteners.
Correction: Correct the hazardous condition. Drain cover shall be installed according to manufacturer's instructions.
Code ATCP 76.34(1) - HAZARDOUS CONDITION AT POOL AREA
-
Not serious
Non-critical
Repeat
-
Sep 15, 2025 Re-inspection 2 · 2 critical, 2 non-critical, 4 repeat
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The pump psi gauge is not being maintained in operating condition.
Correction: Adjust or repair the psi gauge.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
Repeat
LABEL, CONSPICUOUS
Bulk acid container is not labeled.
Correction: Provide a conspicuous, easily visible and read label on the chemical container.
Code ATCP 76.12 (1)(a)
-
Serious
Critical
Repeat
DRINKING FOUNTAIN PROVIDED
There is no drinking fountain provided. Management indicated a new drinking fountain has been ordered.
Correction: Provide a drinking fountain within 300 feet walking distance.
Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED
-
Serious
Critical
Repeat
VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO
The operator of an existing pool does not have the pump curve or drain cover specifications.
Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.
Code ATCP 76.38(1)(b) - PUMP CURVE
-
Not serious
Non-critical
Repeat
-
May 13, 2025 Re-inspection 2 · 2 critical, 2 non-critical, 2 repeat
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The pump psi gauge is not being maintained in operating condition.
Correction: Adjust or repair the psi gauge.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
Repeat
LABEL, CONSPICUOUS
Bulk acid container is not labeled.
Correction: Provide a conspicuous, easily visible and read label on the chemical container.
Code ATCP 76.12 (1)(a)
-
Serious
Critical
DRINKING FOUNTAIN PROVIDED
There is no drinking fountain provided. Management indicated a new drinking fountain has been ordered.
Correction: Provide a drinking fountain within 300 feet walking distance.
Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED
-
Serious
Critical
VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO
The operator of an existing pool does not have the pump curve or drain cover specifications.
Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.
Code ATCP 76.38(1)(b) - PUMP CURVE
-
Not serious
Non-critical
Repeat
-
May 2, 2025 Re-inspection · 3 critical, 2 non-critical, 5 repeat
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The pump psi gauge is not being maintained in operating condition.
Correction: Adjust or repair the psi gauge.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
Repeat
LABEL, CONSPICUOUS
Bulk acid container is not labeled.
Correction: Provide a conspicuous, easily visible and read label on the chemical container.
Code ATCP 76.12 (1)(a)
-
Serious
Critical
Repeat
CHLORINE GENERATOR-DISINFECTION ONLINE
Primary disinfection system is not online and able to automatically provide capacity to superchlorinate and maintain sanitizer residual.
Correction: Ensure that primary disinfection system is online and able to automatically provide capacity to superchlorinate and maintain sanitizer residual.
Code ATCP 76.15 (1)(b) - CHLORINE GENERATOR DISINFECTION ONLINE
-
Serious
Critical
Repeat
DRINKING FOUNTAIN PROVIDED
There is no drinking fountain provided. Management indicated a new drinking fountain has been ordered.
Correction: Provide a drinking fountain within 300 feet walking distance.
Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED
-
Serious
Critical
Repeat
VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO
The operator of an existing pool does not have the pump curve or drain cover specifications.
Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.
Code ATCP 76.38(1)(b) - PUMP CURVE
-
Not serious
Non-critical
Repeat
-
Apr 29, 2025 Routine · 5 critical, 6 non-critical, 2 repeat
-
Not serious
Non-critical
Repeat
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Skimmer wier is missing.
Correction: Repair or replace weirs as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The pump psi gauge is not being maintained in operating condition.
Correction: Adjust or repair the psi gauge.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
LABEL, CONSPICUOUS
Bulk acid container is not labeled.
Correction: Provide a conspicuous, easily visible and read label on the chemical container.
Code ATCP 76.12 (1)(a)
-
Not serious
Non-critical
ELECTRONIC MONITORING FREQUENCY OF TESTING
The pool, with an electronic monitoring device, has not been manually tested at least once a day with an approved test kit for pH and disinfectant or sanitizer residual.
Correction: Manually test the pool at least once a day for pH and disinfectant or sanitizer residual with an approved test kit.
Code ATCP 76.18(3)(a) - ELECTRONIC MONITORING TEST FREQ
-
Not serious
Non-critical
ELECTRONIC MONITORING MAINTENANCE
The electronic monitoring device has not been periodically monitored for proper functioning. Controller does not appear to be properly calibrated or functioning. System observed in need of cleaning.
Correction: Periodically monitor the electronic monitoring device to determine if it is functioning correctly, and maintain and test as appropriate.
Code ATCP 76.18(3)(b) - ELECTRONIC MONITORING DEVICE MAINTAINED
-
Not serious
Non-critical
TELEPHONE-EMERGENCY NUMBERS AND ADDRESS
The facility address not attached or posted near telephone.
Correction: Provide a list of emergency numbers and facility address, attached or posted near telephone or other telecommunication technology device.
Code ATCP 76.26(2)(d) - TELEPHONE, EMERGENCY NUMBERS POSTED
-
Serious
Critical
CHLORINE GENERATOR-DISINFECTION ONLINE
Primary disinfection system is not online and able to automatically provide capacity to superchlorinate and maintain sanitizer residual.
Correction: Ensure that primary disinfection system is online and able to automatically provide capacity to superchlorinate and maintain sanitizer residual.
Code ATCP 76.15 (1)(b) - CHLORINE GENERATOR DISINFECTION ONLINE
-
Serious
Critical
FIRST AID KIT-PROVIDED IN POOL AREA
The first aid kit is missing from the pool area, or within 25 feet of enclosure with signage posted in the enclosure telling where the first aid kit is.
Correction: Provide a first aid kit in the pool area or, if the first aid kit is within 25 feet of the enclosure, post signage that tells where the first aid kit is located.
Code ATCP 76.27(1)(a) - FIRST AID KIT PRESENT
-
Serious
Critical
Repeat
DRINKING FOUNTAIN PROVIDED
There is no drinking fountain provided. Management indicated a new drinking fountain has been ordered.
Correction: Provide a drinking fountain within 300 feet walking distance.
Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED
-
Serious
Critical
HAZARDOUS CONDITION
There is a hazardous condition at the pool. The main drain grate is missing a screw and not maintained in good repair.
Correction: Correct the hazardous condition. Repair main drain cover.
Code ATCP 76.34(1) - HAZARDOUS CONDITION AT POOL AREA
-
Serious
Critical
VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO
The operator of an existing pool does not have the pump curve or drain cover specifications.
Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.
Code ATCP 76.38(1)(b) - PUMP CURVE
-
Not serious
Non-critical
Repeat
-
Oct 4, 2023 Re-inspection · 1 critical, 2 non-critical, 3 repeat
-
Not serious
Non-critical
Repeat
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Skimmers not repaired or replaced as needed. Weir door is missing.
Correction: Repair or replace skimmer, weirs or gutters as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
Repeat
VGBA DRAIN COVER INFO-LIFESPAN
The VGBA log indicates the equalizer cover is expired.
Correction: Replace equalizer cover.
Code ATCP 76.38(2)(b)4. - LIFESPAN
-
Serious
Critical
Repeat
DRINKING FOUNTAIN PROVIDED
There is no drinking fountain provided. The drinking fountains are not fuctioning.
Correction: Provide a drinking fountain within 300 feet walking distance.
Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED
-
Not serious
Non-critical
Repeat
-
Sep 27, 2023 Routine · 2 critical, 2 non-critical
-
Not serious
Non-critical
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Skimmers not repaired or replaced as needed. Weir door is missing.
Correction: Repair or replace skimmer, weirs or gutters as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
VGBA DRAIN COVER INFO-LIFESPAN
The VGBA log indicates the equalizer cover is expired.
Correction: Replace equalizer cover.
Code ATCP 76.38(2)(b)4. - LIFESPAN
-
Serious
Critical
CLOSING CRITERIA-NO FUNCTIONAL EMERGENCY PHONE
The Responsible Supervisor or operator has not closed the pool due to a nonfunctional emergency phone.
Correction: Close the pool in the event of a nonfunctional emergency phone.
Code ATCP 76.30 (1)(g) - FUNCTIONAL EMERGENCY PHONE
-
Serious
Critical
DRINKING FOUNTAIN PROVIDED
There is no drinking fountain provided. The drinking fountains are not fuctioning.
Correction: Provide a drinking fountain within 300 feet walking distance.
Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED
-
Not serious
Non-critical
Source: Waukesha County Environmental Health. History last read Nov 21, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.