RecordWell Data

Meadowbrook Village Recreation Center-whirlpool

N17W26440 MEADOWGRASS, Pewaukee, WI 53072 · Waukesha County

34cited violations
10serious tier
4inspections

Establishment

Type
Pool / recreational water (Pool - Moderate)
Inspected by
Waukesha County Environmental Health
License / ID
HSAT-96F3LA
Status
Permitted
Official record
Waukesha County Environmental Health inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20252299
2024141
2023110

Inspections

  1. Aug 29, 2025 Re-inspection · 4 critical, 10 non-critical, 14 repeat
    • Not serious Non-critical Repeat

      SAFETY DATA SHEET

      A safety data sheet was not available for pool chemicals.

      Correction: Maintain a safety data sheet for each chemical on site.

      Code ATCP 76.12 (4)(b)1. - SAFETY DATA SHEETS

    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical Repeat

      WHIRLPOOL, THERAPY POOL, EXERCISE POOL,COMBINED CHLORINE

      Chlorine is used in the whirlpool and the pool water is not tested at least twice a week for the combined chlorine level.

      Correction: Test pool water at least twice a week for the combined chlorine level.

      Code ATCP 76.18(2)(b) - COMBINED CHLORINE, WHIRLPOOL, EX, THERAPY

    • Not serious Non-critical Repeat

      WHIRLPOOL, THERAPY POOL, EXERCISE POOL, CYANURIC

      Cyanuric acid is used in the whirlpool and the cyanuric acid concentration is not tested at least once a week.

      Correction: Test water for the cyanuric acid at least once a week.

      Code ATCP 76.18(2)(d) - CYANURIC, WHIRL, EX, THERAPY

    • Not serious Non-critical Repeat

      POOL RULES LETTER OR SYMBOL SIZE

      Pool rules letters are 3/4 inches in height.

      Correction: Correct the size of the letters or symbols, so that letters are at least one inch in height and symbols are at least 4 inches in height.

      Code ATCP 76.29(1)(a)2. -LETTER OR SYMBOL SIZE

    • Not serious Non-critical Repeat

      FILES MAINTAINED PERMANENT-ATCP 76 CURRENT COPY

      A copy of the most current version of ch. ATCP 76 was not permanently maintained on premises:

      Correction: Maintain a copy of the most current version of ch. ATCP 76 on premises.

      Code ATCP 76.32(3)(a)1. - CURRENT ATCP 76 COPY

    • Not serious Non-critical Repeat

      FILES MAINTAINED PERMANENT-PUMP CURVE

      The manufacturer’s pump performance curve diagram was not permanently maintained on premises:

      Correction: Maintain a copy of the manufacturer’s pump performance curve diagram on the premises.

      Code ATCP 76.32(3)(a)3. - PUMP CURVE

    • Not serious Non-critical Repeat

      FILES MAINTAINED PERMANENT-CDC FECAL INCIDENTS

      The most recent United States centers for disease control and prevention recommendations for fecal accidents or another plan in response to fecal accidents was not permanently maintained on premises:

      Correction: Maintain a copy of the most recent United States centers for disease control and prevention recommendations for fecal accidents or another plan in response to fecal accidents that is consistent with the United States centers for disease control and prevention’s fecal accident response recommendations on the premises.

      Code ATCP 76.32(3)(a)8. - CDC FECAL RESPONSE GUIDELINES

    • Not serious Non-critical Repeat

      FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION

      The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises.

      Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises.

      Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER

    • Not serious Non-critical Repeat

      FILES RETAINED 2 YEARS-FECAL ACCIDENT REPORT

      Fecal accident report (s) not maintained on premises for 2 years.

      Correction: Maintain on premises for 2 years any fecal accident report made.

      Code ATCP 76.32(3)(b)3. - FECAL INCIDENT RESPONSE

    • Serious Critical Repeat

      OPERATOR KNOWLEDGE-FLOW INTERLOCK FUNCTION

      The person responsible is not able to describe how the system flow sensing interlock functions.

      Correction: Ensure that operator can describe how the system flow sensing interlock functions.

      Code ATCP 76.13 (1)(c)2.c - HOW FLOW INTERLOCK FUNCTIONS

    • Serious Critical Repeat

      CO ALARM-POOL EQUIPMENT ROOM

      There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.

      Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.

      Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM

    • Serious Critical Repeat Corrected on site

      HAZARDOUS CONDITION

      One of the main drain covers is missing a screw.

      Correction: Person-in-charge found the missing screw in the pump room and was able to install it during the inspection. Corrected.

      Code ATCP 76.34(1) - HAZARDOUS CONDITION AT POOL AREA

    • Serious Critical Repeat

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      The operator of an existing pool does not have the pump curve or drain cover specifications.

      Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  2. Aug 28, 2025 Routine · 5 critical, 10 non-critical, 2 repeat
    • Not serious Non-critical

      SAFETY DATA SHEET

      A safety data sheet was not available for pool chemicals.

      Correction: Maintain a safety data sheet for each chemical on site.

      Code ATCP 76.12 (4)(b)1. - SAFETY DATA SHEETS

    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      WHIRLPOOL, THERAPY POOL, EXERCISE POOL,COMBINED CHLORINE

      Chlorine is used in the whirlpool and the pool water is not tested at least twice a week for the combined chlorine level.

      Correction: Test pool water at least twice a week for the combined chlorine level.

      Code ATCP 76.18(2)(b) - COMBINED CHLORINE, WHIRLPOOL, EX, THERAPY

    • Not serious Non-critical Repeat

      WHIRLPOOL, THERAPY POOL, EXERCISE POOL, CYANURIC

      Cyanuric acid is used in the whirlpool and the cyanuric acid concentration is not tested at least once a week.

      Correction: Test water for the cyanuric acid at least once a week.

      Code ATCP 76.18(2)(d) - CYANURIC, WHIRL, EX, THERAPY

    • Not serious Non-critical

      POOL RULES LETTER OR SYMBOL SIZE

      Pool rules letters are 3/4 inches in height.

      Correction: Correct the size of the letters or symbols, so that letters are at least one inch in height and symbols are at least 4 inches in height.

      Code ATCP 76.29(1)(a)2. -LETTER OR SYMBOL SIZE

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-ATCP 76 CURRENT COPY

      A copy of the most current version of ch. ATCP 76 was not permanently maintained on premises:

      Correction: Maintain a copy of the most current version of ch. ATCP 76 on premises.

      Code ATCP 76.32(3)(a)1. - CURRENT ATCP 76 COPY

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-PUMP CURVE

      The manufacturer’s pump performance curve diagram was not permanently maintained on premises:

      Correction: Maintain a copy of the manufacturer’s pump performance curve diagram on the premises.

      Code ATCP 76.32(3)(a)3. - PUMP CURVE

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-CDC FECAL INCIDENTS

      The most recent United States centers for disease control and prevention recommendations for fecal accidents or another plan in response to fecal accidents was not permanently maintained on premises:

      Correction: Maintain a copy of the most recent United States centers for disease control and prevention recommendations for fecal accidents or another plan in response to fecal accidents that is consistent with the United States centers for disease control and prevention’s fecal accident response recommendations on the premises.

      Code ATCP 76.32(3)(a)8. - CDC FECAL RESPONSE GUIDELINES

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION

      The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises.

      Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises.

      Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER

    • Not serious Non-critical

      FILES RETAINED 2 YEARS-FECAL ACCIDENT REPORT

      Fecal accident report (s) not maintained on premises for 2 years.

      Correction: Maintain on premises for 2 years any fecal accident report made.

      Code ATCP 76.32(3)(b)3. - FECAL INCIDENT RESPONSE

    • Serious Critical

      OPERATOR KNOWLEDGE-FLOW INTERLOCK FUNCTION

      The person responsible is not able to describe how the system flow sensing interlock functions.

      Correction: Ensure that operator can describe how the system flow sensing interlock functions.

      Code ATCP 76.13 (1)(c)2.c - HOW FLOW INTERLOCK FUNCTIONS

    • Serious Critical Repeat

      MINIMUM DISINFECTANT RESIDUAL

      Minimum disinfectant or sanitizer level for the whirlpool is not at a minimum of 3 PPM.

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A. When the whirlpool was drained in order to install the missing screw, and re-filled, the pool operator re-tested the pool chemistry and was at 3.0 PPM.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

    • Serious Critical

      CO ALARM-POOL EQUIPMENT ROOM

      There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.

      Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.

      Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM

    • Serious Critical Corrected on site

      HAZARDOUS CONDITION

      One of the main drain covers is missing a screw.

      Correction: Person-in-charge found the missing screw in the pump room and was able to install it during the inspection. Corrected.

      Code ATCP 76.34(1) - HAZARDOUS CONDITION AT POOL AREA

    • Serious Critical

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      The operator of an existing pool does not have the pump curve or drain cover specifications.

      Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  3. Aug 27, 2024 Routine · 1 critical, 3 non-critical
    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flowmeter is not being maintained in operating condition as it is stuck.

      Correction: Replace the flowmeter as it is difficult to read as the numbers are faded and scratched. This shall be addressed prior to the start of the next pool season.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical

      LABEL, STORE, MIX CHEMICALS, LOCAL, STATE AND FEDERAL COMPLIANCE

      Labeling, storing, mixing, and handling of chemicals is not in compliance with applicable local, state, and federal regulations. There is a chemical container on top of the Calcium increaser container that has a label, but the label is faded and the lettering is hand written. This shall be addressed prior to the start of the spring pool season.

      Correction: Comply with applicable local, state, and federal regulations.

      Code ATCP 76.12 - CHEMICALS COMPLIANCE WITH OTHER STATE, FEDERAL,

    • Not serious Non-critical

      WHIRLPOOL, THERAPY POOL, EXERCISE POOL, CYANURIC

      Cyanuric acid is used in the whirlpool and the cyanuric acid concentration is not tested and recorded at least once a week.

      Correction: Test water for the cyanuric acid at least once a week.

      Code ATCP 76.18(2)(d) - CYANURIC, WHIRL, EX, THERAPY

    • Serious Critical Corrected on site

      MINIMUM DISINFECTANT RESIDUAL

      Minimum free chlorine level in the whirlpool is between 1.5-1.9 PPM (4 tests were ran). Pool was closed and ORP was adjusted from 700-715. Re-tested free chlorine to 4.1 PPM. Ok to re-open.

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

  4. Jul 24, 2023 Routine · 1 non-critical
    • Not serious Non-critical

      FLOWMETER, VALVES AND GAUGES NOT FUNCTIONAL

      The flowmeter is stuck.

      Correction: Repair or replace the specified equipment so an accurate reading can be recorded.

      Code ATCP 76.11(5)

Source: Waukesha County Environmental Health. History last read Nov 21, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.