RecordWell Data

Fred-elan Apartments LLC

6311 QUARRY VISTA DR, Fitchburg, WI 53719 · Dane County

19cited violations
0serious tier
10inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
LICSWD-2016-00159
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026130
2025130
2024120
20232110
2021100
2019100
2017200
2016100

Inspections

  1. Aug 26, 2026 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      27c - SIGNAGE - SMALL LETTERS

      The letters on the pool rules signage are less than one inch in height.

      Correction: Provide an approved sign.

      Code ATCP 76.29(1)

    • Not serious Action taken:

      27d - SIGNAGE - NO DIVING (Pf)

      'NO DIVING' signage is in lettering 2-3" in height.

      Correction: Post approved signage with letters at least 4 inches in height.

      Code ATCP 76.29(1)(d)

    • Not serious Action taken:

      28e -REPORTS AND RECORDS (Pf)

      Only August testing logs are available for review onsite.

      Correction: Keep the following records available for review. (a) Chemical testing pursuant s. ATCP 76.14. (b) Backwashing completion. (c) Breakpoint chlorination. (d) Interlock testing. (e) Anti-entrapment system testing. (f) Water temperature. (g) Safety and rescue equipment maintaining pursuant to ss. ATCP 76.26 and ATCP 76.27. (h) If monthly reports are requested by the department or its agent, they shall

      Code ATCP 76.32(1)

  2. Aug 19, 2025 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      20e - WATER TESTING FREQUENCY - WITH ELECTRONIC MONITORING DEVICE (Pf)

      The water testing frequency for pH and chlorine is not in compliance with ATCP 76.18(3). Pool is not manually tested on weekends. PIC informed that pool is remotely electronically monitored for pH, chlorine, and ORP based on digital readings in pump room.

      Correction: Perform water testing in accordance with ATCP 76.18(3).

      Code ATCP 76.18(3)

    • Not serious Action taken: PIC installed CO detector Corrected on site

      32d - CARBON MONOXIDE ALARMS (P)

      There is no carbon monoxide alarm in pool equipment room where there is a fuel burning appliance.

      Correction: Install functioning carbon monoxide alarms as applicable.

      Code ATCP 76.33(4)(d)

    • Not serious Action taken: 1. PIC tightened hinge spr Corrected on site

      34d - DOOR/GATE (P)

      1. The gate to the pool enclosure from outside is not self-closing when opened with a smaller opening, there is not enough spring tension to close and latch. 2. An electronic method to exit the pool enclosure is required to re-enter the building. While the door requires a fob to exit, patrons may exit via gate which leads to the parking lot area without a fob.

      Correction: Repair the door immediately so that it is self-closing, latching, lockable, and does not require a key, punch code, or electronic method to exit the pool enclosure.

      Code ATCP 76.34(4)

  3. Aug 8, 2024 Routine Inspection · No Reinspection Required
    • Not serious Action taken: Discussed range.

      16c - ALKALINITY

      The total alkalinity is 20ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(4)(d)

    • Not serious Action taken: Discussed ensuring pool te

      20e - WATER TESTING FREQUENCY - ORP

      The water testing frequency for chlorine and pH is not in compliance with ATCP 76.18(3). Saturday testing is not documented.

      Correction: Perform water testing in accordance with ATCP 76.18(3).

      Code ATCP 76.18(3)

  4. Aug 4, 2023 Re-Inspection · No Reinspection Required
    • Not serious Action taken: PIC informed strainer bask

      06a - SPARE STRAINER BASKET - Not Corrected

      A spare strainer basket for the skimmers is not located on site.

      Correction: Provide a spare basket or screen.

      Code ATCP 76.11(2)(d)

    • Not serious Action taken: Discussed training staff o

      20e - WATER TESTING FREQUENCY - ORP - Not Corrected

      The water testing frequency for pH and chlorine is not in compliance with ATCP 76.18(3). The pool basin is not tested on the weekends when the pool is open.

      Correction: Perform water testing in accordance with ATCP 76.18(3).

      Code ATCP 76.18(3)

    • Not serious Action taken: PIC informed kit was order

      26q - FIRST AID KIT - SUPPLIES MISSING - Not Corrected

      Several items are missing from the first aid kit.

      Correction: Provide all the items listed in ATCP 76.27(1) in the first aid kit.

      Code ATCP 76.27(1)

  5. Aug 3, 2023 Routine Inspection · Reinspection Required
    • Not serious Action taken: PIC adjusted valves. Corrected on site

      05a - SKIMMER/MAIN DRAIN RATIO

      The skimmer to main drain flow ratio is not set correctly. Both valves are fully open.

      Correction: Readjust the flow so that on skimmer pool, only 20% of the flow comes through the main drain and 80% comes through the skimmers. On a gutter pool, 75% of the required recirculation flow shall be through the gutter and 25% through the main drain.

      Code ATCP 76.11(2)(a)

    • Not serious Action taken:

      06a - SPARE STRAINER BASKET

      A spare strainer basket for the skimmers is not located on site.

      Correction: Provide a spare basket or screen.

      Code ATCP 76.11(2)(d)

    • Not serious Action taken:

      16c - ALKALINITY

      The total alkalinity is 30ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(4)(d)

    • Not serious Action taken: Discussed training staff o

      20e - WATER TESTING FREQUENCY - ORP

      The water testing frequency for pH and chlorine is not in compliance with ATCP 76.18(3). The pool basin is not tested on the weekends when the pool is open.

      Correction: Perform water testing in accordance with ATCP 76.18(3).

      Code ATCP 76.18(3)

    • Not serious Action taken:

      26f - PATRON LOAD - NOT POSTED

      The maximum patron load is not posted in the facility.

      Correction: Post the maximum patron load.

      Code ATCP 76.29(1)(d)

    • Not serious Action taken: Pool closed.

      26m - TELEPHONE - NOT WORKING

      The emergency telephone does not work. There is no dial tone.

      Correction: Provide a functional emergency telephone immediately.

      Code ATCP 76.26(2)

    • Not serious Action taken:

      26q - FIRST AID KIT - SUPPLIES MISSING

      Several items are missing from the first aid kit.

      Correction: Provide all the items listed in ATCP 76.27(1) in the first aid kit.

      Code ATCP 76.27(1)

    • Not serious Action taken:

      31b - EQUIPMENT NOT MAINTAINED

      Railings for pool entrance by steps are loose.

      Correction: Repair and maintain all equipment.

      Code ATCP 76.33(1)(e)

  6. Aug 10, 2021 Routine Inspection · No Reinspection Required

    No violations cited.

  7. Jul 31, 2019 Routine Inspection · No Reinspection Required

    No violations cited.

  8. Aug 17, 2017 Routine Inspection · No Reinspection Required

    No violations cited.

  9. May 31, 2017 Routine Inspection · No Reinspection Required

    No violations cited.

  10. Jun 10, 2016 Pre-Inspection · No Reinspection Required

    No violations cited.

Source: Public Health Madison & Dane County. History last read Nov 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.