RecordWell Data

Poplar Creek

20200 POPLAR CREEK PKWY, Brookfield, WI 53045 · Waukesha County

23cited violations
7serious tier
9inspections

Establishment

Type
Pool / recreational water (Pool - Simple)
Inspected by
Waukesha County Environmental Health
License / ID
HDEH-BDYLVX
Status
Permitted
Phone
(262) 264-8420
Official record
Waukesha County Environmental Health inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026211
2025342
2024294
2023290

Inspections

  1. Aug 17, 2026 Re-inspection · No items found

    No violations cited.

  2. Aug 10, 2026 Routine · 1 critical
    • Serious Critical

      RESCUE EQUIPMENT GOOD REPAIR

      The rescue equipment is not in good repair. Shephards crook is not attached. Phone is loose in phone box.

      Correction: Maintain all rescue equipment in good repair.

      Code ATCP 76.26(1)(a)1. - RESCUE EQPT GOOD REPAIR

  3. Aug 26, 2025 Re-inspection · No items found

    No violations cited.

  4. Aug 18, 2025 Follow Up · 1 critical, 1 non-critical, 2 repeat
    • Not serious Non-critical Repeat

      TELEPHONE-EMERGENCY NUMBERS AND ADDRESS

      A list of non-emergency numbers and directions for use are not posted in or near the device.

      Correction: Provide a list of emergency numbers and facility address, attached or posted near telephone or other telecommunication technology device.

      Code ATCP 76.26(2)(d) - TELEPHONE, EMERGENCY NUMBERS POSTED

    • Serious Critical Repeat

      TELEPHONE ACCESSIBLE

      The push button emergency service technology does not have DATCP approval and displays the wrong facility address to emergency services.

      Correction: Provide a working telephone or other technology capable of connecting with emergency services. Emergency dispatch shall be capable of determining the corresponding address with the facilty.

      Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE

  5. Aug 11, 2025 Routine · 1 critical, 1 non-critical, 1 repeat
    • Not serious Non-critical

      TELEPHONE-EMERGENCY NUMBERS AND ADDRESS

      A list of non-emergency numbers and directions for use are not posted in or near the device.

      Correction: Provide a list of emergency numbers and facility address, attached or posted near telephone or other telecommunication technology device.

      Code ATCP 76.26(2)(d) - TELEPHONE, EMERGENCY NUMBERS POSTED

    • Serious Critical Repeat

      TELEPHONE ACCESSIBLE

      The push button emergency service technology does not have DATCP approval and displays the wrong facility address to emergency services.

      Correction: Provide a working telephone or other technology capable of connecting with emergency services. Emergency dispatch shall be capable of determining the corresponding address with the facilty.

      Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE

  6. Aug 8, 2024 Re-inspection · 1 critical, 2 non-critical, 3 repeat
    • Not serious Non-critical Repeat

      SKIMMERS REPAIRED OR REPLACED AS NEEDED

      Weir door missing on north side skimmer.

      Correction: Repair or replace skimmer, weirs or gutters as needed.

      Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED

    • Not serious Non-critical Repeat

      OPERATING REPORTS-CHEMICAL TESTING

      The operator did not record the following on the operating report: Results for chemical testing.

      Correction: Record results on the operating report as indicated on the chemical log.

      Code ATCP 76.32(1)(a) - CHEMICAL TESTING

    • Serious Critical Repeat

      TELEPHONE ACCESSIBLE

      Push button emergency phone requires DATCP variance approval for use.

      Correction: Provide a working telephone or other technology capable of connecting with emergency services.

      Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE

  7. Aug 7, 2024 Routine · 3 critical, 3 non-critical
    • Not serious Non-critical

      SKIMMERS REPAIRED OR REPLACED AS NEEDED

      Weir door missing on north side skimmer.

      Correction: Repair or replace skimmer, weirs or gutters as needed.

      Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED

    • Not serious Non-critical

      ALKALINITY

      The total alkalinity is 40 ppm.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical

      OPERATING REPORTS-CHEMICAL TESTING

      The operator did not record the following on the operating report: Results for chemical testing.

      Correction: Record results on the operating report as indicated on the chemical log.

      Code ATCP 76.32(1)(a) - CHEMICAL TESTING

    • Serious Critical

      MINIMUM DISINFECTANT RESIDUAL

      Minimum disinfectant or sanitizer level is 0 ppm free chlorine

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

    • Serious Critical

      TELEPHONE ACCESSIBLE

      Push button emergency phone requires DATCP variance approval for use.

      Correction: Provide a working telephone or other technology capable of connecting with emergency services.

      Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE

    • Serious Critical

      GATES AND DOORS-SELF-CLOSING

      The gate to the stairwell does not self-close.

      Correction: Provide a self-closing gate or door.

      Code ATCP 76.34(4)(a)(1m)(a) -SELF-CLOSING

  8. Aug 4, 2023 Re-inspection · 4 non-critical, 4 repeat
    • Not serious Non-critical Repeat

      FLOWMETER, VALVES AND GAUGES NOT FUNCTIONAL

      The flow meter is non functional.

      Correction: Repair or replace the specified equipment so an accurate reading can be recorded.

      Code ATCP 76.11(5)

    • Not serious Non-critical Repeat

      ALKALINITY OUT OF BALANCE

      The total alkalinity is 40.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(4)(d)

    • Not serious Non-critical Repeat

      TEST KIT NOT APPROVED

      The test kit used has expired reagents.

      Correction: Replace the test kit with one from the approved list.

      Code ATCP 76.17(1)

    • Not serious Non-critical Repeat Corrected on site

      CHLORINE TOO LOW

      The chlorine residual was 0.8 at the time of the inspection.

      Correction: Close the pool and raise the chlorine residual to [ ] before re-opening.

      Code [A] ATCP 76.14(4)(a)

  9. Aug 3, 2023 Routine · 5 non-critical, 1 repeat
    • Not serious Non-critical

      FLOWMETER, VALVES AND GAUGES NOT FUNCTIONAL

      The flow meter is non functional.

      Correction: Repair or replace the specified equipment so an accurate reading can be recorded.

      Code ATCP 76.11(5)

    • Not serious Non-critical Repeat

      ALKALINITY OUT OF BALANCE

      The total alkalinity is 40.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(4)(d)

    • Not serious Non-critical

      COMBINED CHLORINE

      The combined chlorine is 1.7.

      Correction: Treat the pool with breakpoint chlorination using a chlorine product or a nonchlorinated oxidizer.

      Code ATCP 76.14(4)(e)

    • Not serious Non-critical

      TEST KIT NOT APPROVED

      The test kit used has expired reagents.

      Correction: Replace the test kit with one from the approved list.

      Code ATCP 76.17(1)

    • Not serious Non-critical Corrected on site

      CHLORINE TOO LOW

      The chlorine residual was 0.8 at the time of the inspection.

      Correction: Close the pool and raise the chlorine residual to [ ] before re-opening.

      Code [A] ATCP 76.14(4)(a)

Source: Waukesha County Environmental Health. History last read Nov 21, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.