Caroline Heights Apartments

13125 WATERTOWN PLANK RD, Elm Grove, WI 53122 · Waukesha County

10cited violations
7serious tier
5inspections

Establishment

Type
Pool / recreational water (Pool - Simple)
Inspected by
Waukesha County Environmental Health
License / ID
HDEH-DB5G9P
Status
Permitted
Phone
(262) 373-9773
Official record
Waukesha County Environmental Health inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026296
2025311

Inspections

  1. Jul 7, 2026 Re-inspection · 1 critical, 1 non-critical, 1 repeat
    • Not serious Non-critical

      ELECTRONIC MONITORING WATER POTENTIAL

      The water potential ("ORP") is less than 650 mV. The operator shall test the pool twice daily until the OPR is maintained between 650 mV and 900 mV. UPDATE (7/7): The ORP is 639-664 during the inspection. Daily operating reports indicate that the ORP has consistently been below 650 mV. The operator shall test the pool twice daily until the OPR is maintained between 650 mV and 900 mV.

      Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.

      Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL

    • Serious Critical Repeat

      INTERLOCK CHALLENGE TEST

      Once monthly challenge testing of the chemical feeder system has not been conducted to assess the interlock.

      Correction: Challenge test the chemical feeder system monthly to assess the interlock.

      Code ATCP 76.13 (1)(c)3. - INTERLOCK MONTHLY TEST

  2. Jun 29, 2026 Routine · 5 critical, 2 non-critical
    • Not serious Non-critical

      ELECTRONIC MONITORING WATER POTENTIAL

      The water potential ("ORP") is less than 650 mV. The operator shall test the pool twice daily until the OPR is maintained between 650 mV and 900 mV.

      Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.

      Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL

    • Not serious Non-critical

      POOL EQUIPMENT-PROPERLY MAINTAINED

      The pH probe is not accurate +/- 0.2.

      Correction: Maintain the pool equipment.

      Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT

    • Serious Critical

      CHEMICAL STORAGE ACCESS RESTRICTED

      Chemical storage area access not restricted to authorized personnel only. The locking mechanism on the door handle to the pump room is not functioning.

      Correction: Restrict access to chemical storage area to only authorized personnel.

      Code ATCP 76.12 (2)(d) - ACCESS RESTRICTED

    • Serious Critical

      INTERLOCK CHALLENGE TEST

      Once monthly challenge testing of the chemical feeder system has not been conducted to assess the interlock.

      Correction: Challenge test the chemical feeder system monthly to assess the interlock.

      Code ATCP 76.13 (1)(c)3. - INTERLOCK MONTHLY TEST

    • Serious Critical Corrected on site

      TELEPHONE-OTHER TECHNOLOGIES,RELIABLE SERVICE CONNECTION

      Push button emergency phone does not have reliable service connection. The device did not connect to emergency services after ringing several times; the device connected to emergency services on the second test.

      Correction: Provide a reliable service connection for the communication technology.

      Code ATCP 76.26(2)(b)2. - TELEPHONE, OTHER TECHNOLOGIES, CONNECTI

    • Serious Critical

      CO ALARM-POOL EQUIPMENT ROOM

      There is a fuel-burning device in the pump room but no CO alarm.

      Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.

      Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM

    • Serious Critical

      GATES AND DOORS-SELF-CLOSING

      The east-most gate does not self-close. The maintenance staff locked the gate so that it can not be used by patrons during the inspection.

      Correction: Provide a self-closing gate or door.

      Code ATCP 76.34(4)(a)(1m)(a) -SELF-CLOSING

  3. Jul 14, 2025 Follow Up · No items found

    No violations cited.

  4. Jun 18, 2025 Pre-inspection Follow Up · 1 critical
    • Serious Critical

      TELEPHONE ACCESSIBLE

      A emergency push-button phone connects to a third-party emergency call center.

      Correction: Provide a working telephone or other technology capable of connecting with emergency services.

      Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE

  5. Jun 6, 2025 Pre-inspection · No items found

    No violations cited.

Source: Waukesha County Environmental Health. History last read Nov 21, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.