Monterey Apartments
2725 N UNIVERSITY DR, Waukesha, WI 53188 · Waukesha County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- Waukesha County Environmental Health
- License / ID
- HSAT-96F3KB
- Status
- Permitted
- Phone
- (262) 549-1212
- Official record
- Waukesha County Environmental Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 0 | 0 |
| 2025 | 2 | 8 | 6 |
| 2024 | 1 | 1 | 0 |
| 2023 | 2 | 2 | 0 |
Inspections
-
Jun 15, 2026 Routine · No items found
No violations cited.
-
Aug 26, 2025 Follow Up · 1 non-critical
-
Not serious
Non-critical
LANDSCAPING-TREES
Trees used as landscaping features overhang the required deck area.
Correction: Make sure trees do not overhang the required deck area.
Code ATCP 76.34(6)(d) - TREES
-
Not serious
Non-critical
-
Jun 23, 2025 Routine · 6 critical, 1 non-critical
-
Not serious
Non-critical
BIOHAZARD KIT-AVAILABLE
A biohazard kit is not available.
Correction: Provide a biohazard kit for the pool.
Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE
-
Serious
Critical
TELEPHONE ACCESSIBLE
The emergency telephone connected to emergency services but the 911 dispatcher could not hear the receiver.
Correction: Provide a working telephone or other technology capable of connecting with emergency services.
Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE
-
Serious
Critical
FILES RETAINED 2 YEARS-ANTI-ENTRAPMENT TEST
Anti-entrapment device or system test results as required by manufacturer and corrective actions taken, if needed, were not maintained on premises for 2 years.
Correction: Maintain on premises for 2 years reports of anti-entrapment device or system test results as required by manufacturer and corrective actions taken, if needed.
Code ATCP 76.32(3)(b)1. - ANTIENTRAPMENT TEST RESULTS
-
Serious
Critical
GATES AND DOORS-SELF-CLOSING
The seconary gate does not self-close.
Correction: Provide a self-closing gate or door.
Code ATCP 76.34(4)(a)(1m)(a) -SELF-CLOSING
-
Serious
Critical
GATES AND DOORS-LATCHING
The secondary gate does not latch.
Correction: Provide a latching door.
Code ATCP 76.34(4)(a)(1m)(b)- LATCHING
-
Serious
Critical
GATES AND DOORS-LOCKABLE
The secondary gate or door does not lock.
Correction: Provide a lockable door.
Code ATCP 76.34(4)(a)(1m)(c)- LOCKABLE
-
Serious
Critical
GATES AND DOORS EXIT
An electronic method is required to exit a pool enclosure.
Correction: Provide an exit from the pool enclosure that does not require a key, punch code, or electronic method to exit a pool enclosure.
Code ATCP 76.34(4)(a)(1m)(d)- EXIT UNRESTRICTED
-
Not serious
Non-critical
-
Jun 17, 2024 Routine · 1 non-critical
-
Not serious
Non-critical
POSTING SIGNAGE-SUPERVISION OF CHILDREN
At a non-lifeguarded pool, no signage stating that children under 12 must be supervised is present.
Correction: Post signage stating that children under 12 must be supervised.
Code ATCP 76.29(1)(c) - SUPERVISE CHILDREN
-
Not serious
Non-critical
-
Jun 26, 2023 Re-inspection · No items found
No violations cited.
-
Jun 16, 2023 Routine · 2 non-critical
-
Not serious
Non-critical
RECIRCULATION RATE NOT MET - POOLS
The swimming pool or combination pool has a maximum turnover rate of greater than 6 hours.
Correction: Immediately adjust or repair the equipment to operate at a proper turnover rate.
Code ATCP 76.11(4)(a)
-
Not serious
Non-critical
CYANURIC ACID >30 PPM
The cyanuric acid concentration is 40 PPM or greater.
Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.
Code ATCP 76.14(4)(b)
-
Not serious
Non-critical
Source: Waukesha County Environmental Health. History last read Nov 21, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.