| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 2 | 15 | 3 |
Inspections
-
Jul 22, 2026 Pre-inspection Follow Up · 1 priority, 1 priority foundation, 5 core, 7 repeat
-
Serious
Priority
Repeat
TOXIC SUBSTANCES - SANITIZER CRITERIA
Silver Source bleach, used in the food establishment for sanitizing in the kitchen is not approved. Bleach does not have an EPA registered number on it and does not have directions for sanitizing food contact surfaces.
Correction: Sanitizer shall meet the requirements under 40 CFR 180.940 or 40 CFR 180.2020.
Code 7-204.11
-
Not serious
Priority Foundation
Repeat
WAREWASHING - CHEMICAL SANITIZER CONCENTRATION - TEST KIT
No quaternary ammonium (quat) or Chlorine (bleach) test kit are available for monitoring sanitizer concentration.
Correction: Provide a test kit to allow accurate determination of the sanitization concentration.
Code 4-501.116
-
Not serious
Core
Repeat
EQUIPMENT AND UTENSILS CONFORM TO ANSI STANDARDS
"Drew" mixer is not ANSI certified or approved by the department. Unit states for household use only on it.
Correction: Unapproved equipment shall be removed from food service.
Code 4-205.11
-
Not serious
Core
Repeat
HANDWASHING SINKS, INSTALLATION - NON-HAND OPERATED
Far left basin of the kitchen 4-compartment sink, which will be used for handwashing and the women's restroom handwashing sink (which will be used by employees) are not non-hand operated as the handles are of the short type.
Correction: Employee handwashing sinks shall be non hand operated and if metered shall provide a flow of water without the need for reactivation for at least 15 seconds.
Code 5-202.12 (C)
-
Not serious
Core
Repeat
PLUMBING - SYSTEM MAINTAINED IN GOOD REPAIR
There is a leak on the faucet arm of the bar compartment sink.
Correction: The plumbing system shall be maintained in good repair. Repair or replace defective or leaking plumbing.
Code 5-205.15 (B)
-
Not serious
Core
Repeat
SURFACE CHARACTERISTICS - INDOOR AREAS
The floor, wall and ceiling in the beer walk-in cooler does not meet the minimum requirment of smooth, durable and easily cleanable. Wood is present for floor, walls and ceiling. If paint will be used, it shall be semi gloss, high gloss, or polyurethane based in order to provide a non absorbant surface.
Correction: Repair area or replace with approved materials. Walls, floors and ceilings shall be smooth, durable and easily cleanable. If located in areas subject to moisture they shall also be non-absorbent.
Code 6-101.11
-
Not serious
Core
Repeat
HANDWASHING SIGNAGE
No handwashing signage provided at the kitchen handwashing sink.
Correction: Provide handwashing signage at all handwashing sinks used by food employees.
Code 6-301.14
-
Serious
Priority
Repeat
-
Jul 7, 2026 Pre-inspection · 2 priority, 1 priority foundation, 5 core
-
Serious
Priority
PLUMBING - BACKFLOW PREVENTION - AIR GAP
Bar ice bins are not provided with an air gap. Both ice bins drain to the same floor drain.
Correction: Provide an air gap on water supply side to protect water supply.
Code 5-202.13
-
Serious
Priority
TOXIC SUBSTANCES - SANITIZER CRITERIA
Silver Source bleach, used in the food establishment for sanitizing in the kitchen is not approved. Bleach does not have an EPA registered number on it and does not have directions for sanitizing food contact surfaces.
Correction: Sanitizer shall meet the requirements under 40 CFR 180.940 or 40 CFR 180.2020.
Code 7-204.11
-
Not serious
Priority Foundation
WAREWASHING - CHEMICAL SANITIZER CONCENTRATION - TEST KIT
No quaternary ammonium (quat) or Chlorine (bleach) test kit are available for monitoring sanitizer concentration.
Correction: Provide a test kit to allow accurate determination of the sanitization concentration.
Code 4-501.116
-
Not serious
Core
EQUIPMENT AND UTENSILS CONFORM TO ANSI STANDARDS
"Drew" mixer is not ANSI certified or approved by the department. Unit states for household use only on it.
Correction: Unapproved equipment shall be removed from food service.
Code 4-205.11
-
Not serious
Core
HANDWASHING SINKS, INSTALLATION - NON-HAND OPERATED
Far left basin of the kitchen 4-compartment sink, which will be used for handwashing and the women's restroom handwashing sink (which will be used by employees) are not non-hand operated as the handles are of the short type.
Correction: Employee handwashing sinks shall be non hand operated and if metered shall provide a flow of water without the need for reactivation for at least 15 seconds.
Code 5-202.12 (C)
-
Not serious
Core
PLUMBING - SYSTEM MAINTAINED IN GOOD REPAIR
There is a leak on the faucet arm of the bar compartment sink.
Correction: The plumbing system shall be maintained in good repair. Repair or replace defective or leaking plumbing.
Code 5-205.15 (B)
-
Not serious
Core
SURFACE CHARACTERISTICS - INDOOR AREAS
The floor, wall and ceiling in the beer walk-in cooler does not meet the minimum requirment of smooth, durable and easily cleanable. Wood is present for floor, walls and ceiling. If paint will be used, it shall be semi gloss, high gloss, or polyurethane based in order to provide a non absorbant surface.
Correction: Repair area or replace with approved materials. Walls, floors and ceilings shall be smooth, durable and easily cleanable. If located in areas subject to moisture they shall also be non-absorbent.
Code 6-101.11
-
Not serious
Core
HANDWASHING SIGNAGE
No handwashing signage provided at the kitchen handwashing sink.
Correction: Provide handwashing signage at all handwashing sinks used by food employees.
Code 6-301.14
-
Serious
Priority