Norhardt Crossing
1930 NORHARDT DR, Brookfield, WI 53045 · Waukesha County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- Waukesha County Environmental Health
- License / ID
- HDEH-AAYHLH
- Status
- Permitted
- Official record
- Waukesha County Environmental Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 2 | 0 |
| 2025 | 2 | 3 | 0 |
| 2024 | 2 | 2 | 0 |
| 2023 | 3 | 3 | 0 |
Inspections
-
Jun 25, 2026 Routine · 2 non-critical
-
Not serious
Non-critical
REAGENTS REPLACED
Test kit reagents not replaced as recommended by the manufacturer. Observed expired chemicals
Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.
Code ATCP 76.17 (2)(b) - REAGENTS REPLACED
-
Not serious
Non-critical
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement. All documentation Waukesha County has avaialable indicates drain covers are expired. Facility will be following up with pool company to obtain all information for grates. Facility shall forward all updated grate information to our office at adalgren@waukeshacounty.gov.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Not serious
Non-critical
-
Jul 7, 2025 Follow Up · 1 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
OPERATING REPORTS-INTERLOCK TESTING
The operator did not record the following on the operating report: Dates of interlock tests, results and comments.
Correction: Record the following on the operating report, dates of interlock tests, results and comments.
Code ATCP 76.32(1)(d) - INTERLOCK TEST
-
Not serious
Non-critical
Repeat
-
Jun 26, 2025 Routine · 2 non-critical
-
Not serious
Non-critical
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is 577 mV and water has not been tested manually.
Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV. Replacement if probes may be required. Pool operator had two new probes already purchased. Maintain increased chemical testing to twice per day until probes can be replaced. Once probes are replaced, please email our department indicating ORP MV reading if 650MV or ab
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Not serious
Non-critical
OPERATING REPORTS-INTERLOCK TESTING
The operator did not record the following on the operating report: Dates of interlock tests, results and comments.
Correction: Record the following on the operating report, dates of interlock tests, results and comments.
Code ATCP 76.32(1)(d) - INTERLOCK TEST
-
Not serious
Non-critical
-
Aug 30, 2024 Follow Up · No items found
No violations cited.
-
Aug 19, 2024 Routine · 2 non-critical
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The Flowmeter is not being maintained in operating condition. Replace flowmeter.
Correction: Adjust or repair the flowmeter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
FILES MAINTAINED PERMANENT-PUMP CURVE
The manufacturer’s pump performance curve diagram was not permanently maintained on premises:
Correction: Maintain a copy of the manufacturer’s pump performance curve diagram on the premises.
Code ATCP 76.32(3)(a)3. - PUMP CURVE
-
Not serious
Non-critical
-
Aug 3, 2023 Re-inspection · No items found
No violations cited.
-
Jul 27, 2023 Re-inspection · 1 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
TELEPHONE NOT WORKING
The emergency telephone does not work.
Correction: Provide a functional emergency telephone immediately.
Code [A] ATCP 76.26(2)
-
Not serious
Non-critical
Repeat
-
Jul 11, 2023 Routine · 2 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
EQUIPMENT NOT MAINTAINED
The hand rail at the stairs is loose.
Correction: Repair and maintain all equipment pursuant to ATCP 76.33(1)(e).
Code ATCP 76.33(1)(e)
-
Not serious
Non-critical
TELEPHONE NOT WORKING
The emergency telephone does not work.
Correction: Provide a functional emergency telephone immediately.
Code [A] ATCP 76.26(2)
-
Not serious
Non-critical
Repeat
Source: Waukesha County Environmental Health. History last read Nov 21, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.