RecordWell Data

Norhardt Crossing

1930 NORHARDT DR, Brookfield, WI 53045 · Waukesha County

10cited violations
0serious tier
8inspections

Establishment

Type
Pool / recreational water (Pool - Simple)
Inspected by
Waukesha County Environmental Health
License / ID
HDEH-AAYHLH
Status
Permitted
Official record
Waukesha County Environmental Health inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026120
2025230
2024220
2023330

Inspections

  1. Jun 25, 2026 Routine · 2 non-critical
    • Not serious Non-critical

      REAGENTS REPLACED

      Test kit reagents not replaced as recommended by the manufacturer. Observed expired chemicals

      Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Not serious Non-critical

      VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT

      The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement. All documentation Waukesha County has avaialable indicates drain covers are expired. Facility will be following up with pool company to obtain all information for grates. Facility shall forward all updated grate information to our office at adalgren@waukeshacounty.gov.

      Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.

      Code ATCP 76.38(2)(a) - DRAIN COVER LOG

  2. Jul 7, 2025 Follow Up · 1 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      OPERATING REPORTS-INTERLOCK TESTING

      The operator did not record the following on the operating report: Dates of interlock tests, results and comments.

      Correction: Record the following on the operating report, dates of interlock tests, results and comments.

      Code ATCP 76.32(1)(d) - INTERLOCK TEST

  3. Jun 26, 2025 Routine · 2 non-critical
    • Not serious Non-critical

      ELECTRONIC MONITORING WATER POTENTIAL

      The water potential ("ORP") is 577 mV and water has not been tested manually.

      Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV. Replacement if probes may be required. Pool operator had two new probes already purchased. Maintain increased chemical testing to twice per day until probes can be replaced. Once probes are replaced, please email our department indicating ORP MV reading if 650MV or ab

      Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL

    • Not serious Non-critical

      OPERATING REPORTS-INTERLOCK TESTING

      The operator did not record the following on the operating report: Dates of interlock tests, results and comments.

      Correction: Record the following on the operating report, dates of interlock tests, results and comments.

      Code ATCP 76.32(1)(d) - INTERLOCK TEST

  4. Aug 30, 2024 Follow Up · No items found

    No violations cited.

  5. Aug 19, 2024 Routine · 2 non-critical
    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The Flowmeter is not being maintained in operating condition. Replace flowmeter.

      Correction: Adjust or repair the flowmeter.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-PUMP CURVE

      The manufacturer’s pump performance curve diagram was not permanently maintained on premises:

      Correction: Maintain a copy of the manufacturer’s pump performance curve diagram on the premises.

      Code ATCP 76.32(3)(a)3. - PUMP CURVE

  6. Aug 3, 2023 Re-inspection · No items found

    No violations cited.

  7. Jul 27, 2023 Re-inspection · 1 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      TELEPHONE NOT WORKING

      The emergency telephone does not work.

      Correction: Provide a functional emergency telephone immediately.

      Code [A] ATCP 76.26(2)

  8. Jul 11, 2023 Routine · 2 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      EQUIPMENT NOT MAINTAINED

      The hand rail at the stairs is loose.

      Correction: Repair and maintain all equipment pursuant to ATCP 76.33(1)(e).

      Code ATCP 76.33(1)(e)

    • Not serious Non-critical

      TELEPHONE NOT WORKING

      The emergency telephone does not work.

      Correction: Provide a functional emergency telephone immediately.

      Code [A] ATCP 76.26(2)

Source: Waukesha County Environmental Health. History last read Nov 21, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.