Parquelynn Village Apartments
4703 VISTA PARK CT, Nashotah, WI 53058 · Waukesha County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- Waukesha County Environmental Health
- License / ID
- HSAT-96F3L5
- Status
- Permitted
- Phone
- (262) 533-4018
- Official record
- Waukesha County Environmental Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 1 | 0 |
| 2025 | 2 | 2 | 0 |
| 2024 | 1 | 4 | 1 |
| 2023 | 1 | 2 | 0 |
Inspections
-
Aug 4, 2026 Routine · 1 non-critical
-
Not serious
Non-critical
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation (turnover) rate has not been met. The current pool turnover rate is 8 hours.
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate of 6 hours. The pool should completely turnover in 6 hours. Recommend measuring the pool volume for accuracy. Pool pump was replaced in 2025.
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
-
Jul 28, 2025 Routine · 1 non-critical
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flow meter is not being maintained in working condition.
Correction: Adjust or repair the flow meter which is not in working condition.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
-
May 22, 2025 Follow Up · 1 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation (turnover) rate has not been met. The pool is turning over every 12 hours.
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate. Turnover rate should be 6 hour or less. Recommend the skimmers are opened to 100% and the main drains open 20%. .
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
Repeat
-
Aug 21, 2024 Routine · 1 critical, 3 non-critical
-
Not serious
Non-critical
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation (turnover) rate has not been met. The pool is turning over every 12 hours.
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate. Turnover rate should be 6 hour or less. Recommend the skimmers are opened to 100% and the main drains open 20%. .
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
CYANURATES 30 PPM LIMIT
The cyanuric acid concentration is 60.
Correction: Lower the water cyanuric acid concentration to 50 ppm or lower. Recommend lowering the pool water level by 6 inches and refilling.
Code ATCP 76.14(5)(b)1 - MAXIMUM CYANURIC
-
Not serious
Non-critical
BIOHAZARD KIT-AVAILABLE
A biohazard kit is not available.
Correction: Provide a biohazard kit for the pool.
Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE
-
Serious
Critical
GATES AND DOORS EXIT
A key, punch code, or electronic method is required to exit a pool enclosure.
Correction: Provide an exit from the pool enclosure that does not require a key, punch code, or electronic method to exit a pool enclosure. Pool will be inspected prior to opening for use in spring to ensure a handle has been installed.
Code ATCP 76.34(4)(a)(1m)(d)- EXIT UNRESTRICTED
-
Not serious
Non-critical
-
Jul 11, 2023 Routine · 2 non-critical, 1 repeat
-
Not serious
Non-critical
RECIRCULATION RATE NOT MET - POOLS
The swimming pool or combination pool has a maximum turnover rate of greater than 6 hours.
Correction: Immediately adjust or repair the equipment to operate at a proper turnover rate.
Code ATCP 76.11(4)(a)
-
Not serious
Non-critical
Repeat
CYANURIC ACID >30 PPM
The cyanuric acid concentration is 80 ppm.
Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.
Code ATCP 76.14(4)(b)
-
Not serious
Non-critical
Source: Waukesha County Environmental Health. History last read Nov 21, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.