YearInspectionsViolationsSerious
20263144
202594320
2024141
2023220

Inspections

  1. Jul 10, 2026 Re-inspection · 4 non-critical, 4 repeat
    • Not serious Non-critical Repeat

      SKIMMERS-ADJUSTED

      Skimmers not adjusted to ensure vigorous skimming. No flow observed through top and left skimmer.

      Correction: Adjust skimmers to maintain vigorous skimming .

      Code ATCP 76.11(2)(a) 1. - SKIMMERS ADJUSTED

    • Not serious Non-critical Repeat

      FIRST AID KIT ITEMS

      The first aid kit is present but missing items.

      Correction: Replace the missing items in the first aid kit.

      Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS

    • Not serious Non-critical Repeat

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Not serious Non-critical Repeat

      AIR MOVEMENT

      Heating, ventilation, and exhaust equipment not maintained and operated to provide air movement to prevent any excessive condensation.

      Correction: Maintain heating, ventilation, and exhaust equipment to provide air movement to prevent any excessive condensation. A referral to building inspection department or fire department will be made.

      Code ATCP 76.33(4)(b) - AIR MOVEMENT

  2. Jul 8, 2026 Routine · 2 critical, 6 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      SKIMMERS-ADJUSTED

      Skimmers not adjusted to ensure vigorous skimming. No flow observed through top and left skimmer.

      Correction: Adjust skimmers to maintain vigorous skimming .

      Code ATCP 76.11(2)(a) 1. - SKIMMERS ADJUSTED

    • Not serious Non-critical

      ALKALINITY

      The total alkalinity is 38.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical

      FIRST AID KIT ITEMS

      The first aid kit is present but missing items.

      Correction: Replace the missing items in the first aid kit.

      Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS

    • Not serious Non-critical

      POSTING SIGNAGE-MAX PATRON LOAD

      Maximum patron load is not posted.

      Correction: Post signage indicating Maximum patron load.

      Code ATCP 76.29(1)(e) - MAX PATRON LOAD

    • Not serious Non-critical

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Not serious Non-critical

      AIR MOVEMENT

      Heating, ventilation, and exhaust equipment not maintained and operated to provide air movement to prevent any excessive condensation.

      Correction: Maintain heating, ventilation, and exhaust equipment to provide air movement to prevent any excessive condensation. A referral to building inspection department or fire department will be made.

      Code ATCP 76.33(4)(b) - AIR MOVEMENT

    • Serious Critical

      MINIMUM DISINFECTANT RESIDUAL

      Minimum disinfectant level is 0.2 ppm Chlorine

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

    • Serious Critical

      CO ALARM-POOL AREA

      There is a fuel-burning device in the equipment room located in the indoor pool area pool but no functional CO alarm is provided in the indoor pool area.

      Correction: Provide a CO alarm in the pool area and install per manufacturer's instructions.

      Code ATCP 76.33(4)(d)2- CO ALARM POOL AREA

  3. Jun 19, 2026 Re-inspection · 2 critical
    • Serious Critical

      MINIMUM DISINFECTANT RESIDUAL

      Minimum disinfectant level is 1.6 ppm.

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

    • Serious Critical

      PH

      The pH is 8.2. 6/19: The pH is 6.6

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

  4. Jun 27, 2025 Re-inspection 2 · No items found

    No violations cited.

  5. Jun 6, 2025 Follow Up · 2 critical, 2 non-critical, 4 repeat
    • Not serious Non-critical Repeat

      SKIMMERS REPAIRED OR REPLACED AS NEEDED

      Weirs are missing from whirlpool skimmers.

      Correction: Replace skimmer weirs as needed.

      Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED

    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool. Combined chlorine observed above an acceptable action level.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Serious Critical Repeat

      MAXIMUM CHLORINE

      The maximum chlorine residual exceeds 10 ppm.

      Correction: Close the pool until the chlorine residual is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(f) - MAXIMUM FREE CHLORINE

    • Serious Critical Repeat

      CERTIFIED OPERATOR REQUIRED AFTER 2 OR MORE REINSPECTIONS IN 3 YEARS

      A pool that is required to have a certified operator does not have one.

      Correction: Provide a certified operator for the pool.

      Code ATCP 76.20(2)(a)2 - CERTIFIED OPERATOR REQUIRED, REINSPECTIO

  6. May 14, 2025 Follow Up · 2 critical, 2 non-critical, 4 repeat
    • Not serious Non-critical Repeat

      SKIMMERS REPAIRED OR REPLACED AS NEEDED

      Weirs are missing from whirlpool skimmers.

      Correction: Replace skimmer weirs as needed.

      Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED

    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool. Combined chlorine observed above an acceptable action level.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Serious Critical Repeat

      MAXIMUM CHLORINE

      The maximum chlorine residual exceeds 10 ppm.

      Correction: Close the pool until the chlorine residual is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(f) - MAXIMUM FREE CHLORINE

    • Serious Critical Repeat

      CERTIFIED OPERATOR REQUIRED AFTER 2 OR MORE REINSPECTIONS IN 3 YEARS

      A pool that is required to have a certified operator does not have one.

      Correction: Provide a certified operator for the pool.

      Code ATCP 76.20(2)(a)2 - CERTIFIED OPERATOR REQUIRED, REINSPECTIO

  7. Apr 25, 2025 Re-inspection 2 · 3 critical, 2 non-critical, 4 repeat
    • Not serious Non-critical Repeat

      SKIMMERS REPAIRED OR REPLACED AS NEEDED

      Weirs are missing from whirlpool skimmers.

      Correction: Replace skimmer weirs as needed.

      Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED

    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool. Combined chlorine observed above an acceptable action level.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Serious Critical

      MAXIMUM CHLORINE

      The maximum chlorine residual exceeds 10 ppm.

      Correction: Close the pool until the chlorine residual is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(f) - MAXIMUM FREE CHLORINE

    • Serious Critical Repeat

      CERTIFIED OPERATOR REQUIRED AFTER 2 OR MORE REINSPECTIONS IN 3 YEARS

      A pool that is required to have a certified operator does not have one.

      Correction: Provide a certified operator for the pool.

      Code ATCP 76.20(2)(a)2 - CERTIFIED OPERATOR REQUIRED, REINSPECTIO

    • Serious Critical Repeat

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      The operator of an existing pool does not have the pump curve or drain cover specifications.

      Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  8. Apr 14, 2025 Re-inspection 2 · 3 critical, 2 non-critical, 4 repeat
    • Not serious Non-critical Repeat

      SKIMMERS REPAIRED OR REPLACED AS NEEDED

      Weirs are missing from whirlpool skimmers.

      Correction: Replace skimmer weirs as needed.

      Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED

    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool. Combined chlorine observed above an acceptable action level.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Serious Critical

      MINIMUM DISINFECTANT RESIDUAL

      The free chlorine concentration in the pool is 0.88 PPM.

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

    • Serious Critical Repeat

      CERTIFIED OPERATOR REQUIRED AFTER 2 OR MORE REINSPECTIONS IN 3 YEARS

      A pool that is required to have a certified operator does not have one.

      Correction: Provide a certified operator for the pool.

      Code ATCP 76.20(2)(a)2 - CERTIFIED OPERATOR REQUIRED, REINSPECTIO

    • Serious Critical Repeat

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      The operator of an existing pool does not have the pump curve or drain cover specifications.

      Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  9. Mar 14, 2025 Re-inspection · 2 critical, 2 non-critical, 4 repeat
    • Not serious Non-critical Repeat

      SKIMMERS REPAIRED OR REPLACED AS NEEDED

      Weirs are missing from whirlpool skimmers.

      Correction: Replace skimmer weirs as needed.

      Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED

    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool. Combined chlorine observed above an acceptable action level.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Serious Critical Repeat

      CERTIFIED OPERATOR REQUIRED AFTER 2 OR MORE REINSPECTIONS IN 3 YEARS

      A pool that is required to have a certified operator does not have one.

      Correction: Provide a certified operator for the pool.

      Code ATCP 76.20(2)(a)2 - CERTIFIED OPERATOR REQUIRED, REINSPECTIO

    • Serious Critical Repeat

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      The operator of an existing pool does not have the pump curve or drain cover specifications.

      Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  10. Mar 13, 2025 Re-inspection 2 · 3 critical, 3 non-critical, 6 repeat
    • Not serious Non-critical Repeat

      SKIMMERS REPAIRED OR REPLACED AS NEEDED

      Weirs are missing from whirlpool skimmers.

      Correction: Replace skimmer weirs as needed.

      Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED

    • Not serious Non-critical Repeat

      ALKALINITY

      The total alkalinity is 49 ppm.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool. Combined chlorine observed above an acceptable action level.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Serious Critical Repeat

      MINIMUM DISINFECTANT RESIDUAL

      Minimum disinfectant or sanitizer level is 1.98 ppm chlorine.

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A (3ppm).

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

    • Serious Critical Repeat

      CERTIFIED OPERATOR REQUIRED AFTER 2 OR MORE REINSPECTIONS IN 3 YEARS

      A pool that is required to have a certified operator does not have one.

      Correction: Provide a certified operator for the pool.

      Code ATCP 76.20(2)(a)2 - CERTIFIED OPERATOR REQUIRED, REINSPECTIO

    • Serious Critical Repeat

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      The operator of an existing pool does not have the pump curve or drain cover specifications.

      Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  11. Mar 12, 2025 Re-inspection 2 · 3 critical, 5 non-critical, 6 repeat
    • Not serious Non-critical

      ALKALINITY

      The total alkalinity is 49 ppm.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical Repeat

      SKIMMERS-ADJUSTED

      Skimmers not adjusted to ensure vigorous skimming. Main drain valve is wide open.

      Correction: Adjust skimmers to maintain vigorous skimming . Adjust main drain valve to increase flow through skimmers.

      Code ATCP 76.11(2)(a) 1. - SKIMMERS ADJUSTED

    • Not serious Non-critical Repeat

      SKIMMERS REPAIRED OR REPLACED AS NEEDED

      Weirs are missing from whirlpool skimmers.

      Correction: Replace skimmer weirs as needed.

      Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED

    • Not serious Non-critical Repeat

      STRAINER BASKET NOT CLEANED DAILY

      The strainer basket observed full of hair and other non-identifiable gunk/debris build up.

      Correction: Clean strainer baskets daily.

      Code ATCP 76.11(2)(d) 3. - CLEANED

    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool. Combined chlorine observed above an acceptable action level.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Serious Critical

      MINIMUM DISINFECTANT RESIDUAL

      Minimum disinfectant or sanitizer level is 1.98 ppm chlorine.

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A (3ppm).

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

    • Serious Critical Repeat

      CERTIFIED OPERATOR REQUIRED AFTER 2 OR MORE REINSPECTIONS IN 3 YEARS

      A pool that is required to have a certified operator does not have one.

      Correction: Provide a certified operator for the pool.

      Code ATCP 76.20(2)(a)2 - CERTIFIED OPERATOR REQUIRED, REINSPECTIO

    • Serious Critical Repeat

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      The operator of an existing pool does not have the pump curve or drain cover specifications.

      Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  12. Feb 27, 2025 Re-inspection · 2 critical, 5 non-critical, 4 repeat
    • Not serious Non-critical

      STRAINER BASKET NOT CLEANED DAILY

      The strainer basket observed full of hair and other non-identifiable gunk/debris build up.

      Correction: Clean strainer baskets daily.

      Code ATCP 76.11(2)(d) 3. - CLEANED

    • Not serious Non-critical

      STRAINER BASKET OR SCREEN -- CONTINUOUS USE, MAINTAINED

      Strainer basket missing.

      Correction: Ensure a strainer basket or screen in in continuous use and maintained.

      Code ATCP 76.11(2)(d)1 - CONTINUOUS USE, MAINTAINED

    • Not serious Non-critical Repeat

      SKIMMERS-ADJUSTED

      Skimmers not adjusted to ensure vigorous skimming. Main drain valve is wide open.

      Correction: Adjust skimmers to maintain vigorous skimming . Adjust main drain valve to increase flow through skimmers.

      Code ATCP 76.11(2)(a) 1. - SKIMMERS ADJUSTED

    • Not serious Non-critical Repeat

      SKIMMERS REPAIRED OR REPLACED AS NEEDED

      Weirs are missing from whirlpool skimmers.

      Correction: Replace skimmer weirs as needed.

      Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED

    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool. Combined chlorine observed above an acceptable action level.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Serious Critical

      CERTIFIED OPERATOR REQUIRED AFTER 2 OR MORE REINSPECTIONS IN 3 YEARS

      A pool that is required to have a certified operator does not have one.

      Correction: Provide a certified operator for the pool.

      Code ATCP 76.20(2)(a)2 - CERTIFIED OPERATOR REQUIRED, REINSPECTIO

    • Serious Critical Repeat

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      The operator of an existing pool does not have the pump curve or drain cover specifications.

      Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  13. Oct 8, 2024 Routine · 1 critical, 3 non-critical
    • Not serious Non-critical

      SKIMMERS-ADJUSTED

      Skimmers not adjusted to ensure vigorous skimming. Main drain valve is wide open.

      Correction: Adjust skimmers to maintain vigorous skimming . Adjust main drain valve to increase flow through skimmers.

      Code ATCP 76.11(2)(a) 1. - SKIMMERS ADJUSTED

    • Not serious Non-critical

      SKIMMERS REPAIRED OR REPLACED AS NEEDED

      Weirs are missing from whirlpool skimmers.

      Correction: Replace skimmer weirs as needed.

      Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED

    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool. Combined chlorine observed above an acceptable action level.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Serious Critical

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      The operator of an existing pool does not have the pump curve or drain cover specifications.

      Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  14. Aug 15, 2023 Re-inspection · 2 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      ALKALINITY OUT OF BALANCE

      The total alkalinity is 20*.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(4)(d)

    • Not serious Non-critical

      COMBINED CHLORINE

      The combined chlorine is 1.2.

      Correction: Treat the pool with breakpoint chlorination using a chlorine product or a nonchlorinated oxidizer.

      Code ATCP 76.14(4)(e)

  15. Aug 14, 2023 Follow Up · No items found

    No violations cited.

Source: Waukesha County Environmental Health. History last read Nov 21, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.