RecordWell Data

The Glen At Seven Stones

W250N4936 WILLIAMS DR, Sussex, WI 53089 · Waukesha County

42cited violations
5serious tier
6inspections

Establishment

Type
Pool / recreational water (Pool - Simple)
Inspected by
Waukesha County Environmental Health
License / ID
HDEH-9L6PLF
Status
Permitted
Official record
Waukesha County Environmental Health inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20262201
20243204
2023120

Inspections

  1. Jul 29, 2026 Re-inspection · 7 non-critical, 7 repeat
    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical Repeat

      TEST KIT APPROVED

      The Taylor 2005 test kit is being used.

      Correction: Provide an approved test kit. Operator stated that they will purchase a Taylor 2006 test kit.

      Code ATCP 76.17 (1) - DEPARTMENT-APPROVED

    • Not serious Non-critical Repeat

      COMBINED CHLORINE TEST

      Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level.

      Correction: Test pool water at least twice a week for the combined chlorine level.

      Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,

    • Not serious Non-critical Repeat

      FILES MAINTAINED PERMANENT-ATCP 76 CURRENT COPY

      A copy of the most current version of ch. ATCP 76 was not permanently maintained on premises:

      Correction: Maintain a copy of the most current version of ch. ATCP 76 on premises.

      Code ATCP 76.32(3)(a)1. - CURRENT ATCP 76 COPY

    • Not serious Non-critical Repeat

      FILES MAINTAINED PERMANENT-PUMP CURVE

      The manufacturer’s pump performance curve diagram was not permanently maintained on premises:

      Correction: Maintain a copy of the manufacturer’s pump performance curve diagram on the premises.

      Code ATCP 76.32(3)(a)3. - PUMP CURVE

    • Not serious Non-critical Repeat

      FILES MAINTAINED PERMANENT-CDC FECAL INCIDENTS

      The most recent United States centers for disease control and prevention recommendations for fecal accidents or another plan in response to fecal accidents was not permanently maintained on premises:

      Correction: Maintain a copy of the most recent United States centers for disease control and prevention recommendations for fecal accidents or another plan in response to fecal accidents that is consistent with the United States centers for disease control and prevention’s fecal accident response recommendations on the premises.

      Code ATCP 76.32(3)(a)8. - CDC FECAL RESPONSE GUIDELINES

    • Not serious Non-critical Repeat

      VGBA DRAIN COVER INFO-GPM

      The VGBA log or other proof does not indicate drain cover gallons per minute rating.

      Correction: Indicate in the log the drain cover gallons per minute rating.

      Code ATCP 76.38(2)(b)3. - COVER GPM RATING

  2. Jul 23, 2026 Routine · 1 critical, 12 non-critical, 2 repeat
    • Not serious Non-critical Corrected on site

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flowmeter is stuck and is not being maintained in operating condition.

      Correction: Pressure valve on the flow meter was released and the flow meter indicator was no longer stuck. Corrected.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical Repeat

      CYANURATES 30 PPM LIMIT

      The cyanuric acid concentration is at 45 PPM

      Correction: Lower the water cyanuric acid concentration to 30 ppm or lower.

      Code ATCP 76.14(5)(b)1 - MAXIMUM CYANURIC

    • Not serious Non-critical

      ALKALINITY

      The total alkalinity is 33 and 36 PPM. Two tests were ran.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      TEST KIT APPROVED

      The Taylor 2005 test kit is being used.

      Correction: Provide an approved test kit. Operator stated that they will purchase a Taylor 2006 test kit.

      Code ATCP 76.17 (1) - DEPARTMENT-APPROVED

    • Not serious Non-critical Repeat

      COMBINED CHLORINE TEST

      Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level.

      Correction: Test pool water at least twice a week for the combined chlorine level.

      Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-ATCP 76 CURRENT COPY

      A copy of the most current version of ch. ATCP 76 was not permanently maintained on premises:

      Correction: Maintain a copy of the most current version of ch. ATCP 76 on premises.

      Code ATCP 76.32(3)(a)1. - CURRENT ATCP 76 COPY

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-PUMP CURVE

      The manufacturer’s pump performance curve diagram was not permanently maintained on premises:

      Correction: Maintain a copy of the manufacturer’s pump performance curve diagram on the premises.

      Code ATCP 76.32(3)(a)3. - PUMP CURVE

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-FILTER OPERATION MANUAL

      The manual of instruction on filter operation was not permanently maintained on premises:

      Correction: Maintain the manual of instruction on filter operation on premises.

      Code ATCP 76.32(3)(a)5. - FILTER MANUAL

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-CDC FECAL INCIDENTS

      The most recent United States centers for disease control and prevention recommendations for fecal accidents or another plan in response to fecal accidents was not permanently maintained on premises:

      Correction: Maintain a copy of the most recent United States centers for disease control and prevention recommendations for fecal accidents or another plan in response to fecal accidents that is consistent with the United States centers for disease control and prevention’s fecal accident response recommendations on the premises.

      Code ATCP 76.32(3)(a)8. - CDC FECAL RESPONSE GUIDELINES

    • Not serious Non-critical

      VGBA DRAIN COVER INFO-GPM

      The VGBA log or other proof does not indicate drain cover gallons per minute rating.

      Correction: Indicate in the log the drain cover gallons per minute rating.

      Code ATCP 76.38(2)(b)3. - COVER GPM RATING

    • Not serious Non-critical

      VGBA DRAIN COVER INFO-LIFESPAN

      The VGBA log or other proof does not indicate drain cover life span.

      Correction: Indicate in the log the drain cover life span.

      Code ATCP 76.38(2)(b)4. - LIFESPAN

    • Serious Critical

      PH

      The pH is 6.9. Two tests were ran by the inspector.

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

  3. Aug 26, 2024 Re-inspection 2 · 1 critical, 5 non-critical, 6 repeat
    • Not serious Non-critical Repeat

      TEST KIT APPROVED

      Aqua Check Pool and Spa testing device is being used to check pool water chemistry. This is not an approved test kit. Residents are using this as the pool supervisor/responsible person is not always on site to test. 2006 Taylor kit is present on site, but it is unclear how often this kit gets used.

      Correction: ATCP 76.17 Water test kits. (1) APPROVED. A test kit of a type approved by the department shall be maintained for testing.

      Code ATCP 76.17 (1) - DEPARTMENT-APPROVED

    • Not serious Non-critical Repeat

      CYANURATES 30 PPM LIMIT

      The cyanuric acid concentration is at 93 and 94 PPM. Two tests were ran. Note: CCH Endurance Chlorine pucks are being used and it does not have Cyanuric Acid present in them. This shall be addressed as soon as possible.

      Correction: Lower the water cyanuric acid concentration to 30 ppm or lower.

      Code ATCP 76.14(5)(b)1 - MAXIMUM CYANURIC

    • Not serious Non-critical Repeat

      REAGENTS REPLACED

      Test kit reagents not replaced as recommended by the manufacturer. Several reagents have dates that are expired or do not have exoiration dates that are ledgible.

      Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Not serious Non-critical Repeat

      COMBINED CHLORINE TEST

      Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level.

      Correction: Test pool water at least twice a week for the combined chlorine level.

      Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,

    • Not serious Non-critical Repeat

      EMERGENCY BLANKETS

      Two emergency blankets in good condition are not available in the pool area.

      Correction: Provide two emergency blankets in good condition in the pool area.

      Code ATCP 76.27(3) - EMERGENCY BLANKETS

    • Serious Critical Repeat

      TELEPHONE ACCESSIBLE

      A telephone or other approved communication technology capable of connecting to emergency services is not working or not present. Pool is closed to the public until the emergency phone is able to dial 911. Pool responisble person/pool manager stated that AT&T serviced it on 8/15/24 and that there were no dialing out to 911 issues. At time of the re-inspection, the phone was not able to dial 911.

      Correction: Provide a working telephone or other technology capable of connecting with emergency services.

      Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE

  4. Aug 16, 2024 Re-inspection · 1 critical, 5 non-critical, 6 repeat
    • Not serious Non-critical Repeat

      CYANURATES 30 PPM LIMIT

      The cyanuric acid concentration is at 93 and 94 PPM. Two tests were ran. Note: CCH Endurance Chlorine pucks are being used and it does not have Cyanuric Acid present in them. This shall be addressed as soon as possible.

      Correction: Lower the water cyanuric acid concentration to 30 ppm or lower.

      Code ATCP 76.14(5)(b)1 - MAXIMUM CYANURIC

    • Not serious Non-critical Repeat

      TEST KIT APPROVED

      Aqua Check Pool and Spa testing device is being used to check pool water chemistry. This is not an approved test kit. Residents are using this as the pool supervisor/responsible person is not always on site to test. 2006 Taylor kit is present on site, but it is unclear how often this kit gets used.

      Correction: ATCP 76.17 Water test kits. (1) APPROVED. A test kit of a type approved by the department shall be maintained for testing.

      Code ATCP 76.17 (1) - DEPARTMENT-APPROVED

    • Not serious Non-critical Repeat

      REAGENTS REPLACED

      Test kit reagents not replaced as recommended by the manufacturer. Several reagents have dates that are expired or do not have exoiration dates that are ledgible.

      Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Not serious Non-critical Repeat

      COMBINED CHLORINE TEST

      Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level.

      Correction: Test pool water at least twice a week for the combined chlorine level.

      Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,

    • Not serious Non-critical Repeat

      EMERGENCY BLANKETS

      Two emergency blankets in good condition are not available in the pool area.

      Correction: Provide two emergency blankets in good condition in the pool area.

      Code ATCP 76.27(3) - EMERGENCY BLANKETS

    • Serious Critical Repeat

      TELEPHONE ACCESSIBLE

      A telephone or other approved communication technology capable of connecting to emergency services is not working or not present. Pool is closed to the public until the emergency phone is able to dial 911. Pool responisble person/pool manager stated that AT&T serviced it on 8/15/24 and that there were no dialing out to 911 issues. At time of the re-inspection, the phone was not able to dial 911.

      Correction: Provide a working telephone or other technology capable of connecting with emergency services.

      Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE

  5. Aug 12, 2024 Routine · 2 critical, 6 non-critical
    • Not serious Non-critical

      CYANURATES 30 PPM LIMIT

      The cyanuric acid concentration is at 93 and 94 PPM. Two tests were ran. Note: CCH Endurance Chlorine pucks are being used and it does not have Cyanuric Acid present in them. This shall be addressed as soon as possible.

      Correction: Lower the water cyanuric acid concentration to 30 ppm or lower.

      Code ATCP 76.14(5)(b)1 - MAXIMUM CYANURIC

    • Not serious Non-critical

      TEST KIT APPROVED

      Aqua Check Pool and Spa testing device is being used to check pool water chemistry. This is not an approved test kit. Residents are using this as the pool supervisor/responsible person is not always on site to test. 2006 Taylor kit is present on site, but it is unclear how often this kit gets used.

      Correction: ATCP 76.17 Water test kits. (1) APPROVED. A test kit of a type approved by the department shall be maintained for testing.

      Code ATCP 76.17 (1) - DEPARTMENT-APPROVED

    • Not serious Non-critical

      REAGENTS REPLACED

      Test kit reagents not replaced as recommended by the manufacturer. Several reagents have dates that are expired or do not have exoiration dates that are ledgible.

      Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Not serious Non-critical

      COMBINED CHLORINE TEST

      Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level.

      Correction: Test pool water at least twice a week for the combined chlorine level.

      Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,

    • Not serious Non-critical

      EMERGENCY BLANKETS

      Two emergency blankets in good condition are not available in the pool area.

      Correction: Provide two emergency blankets in good condition in the pool area.

      Code ATCP 76.27(3) - EMERGENCY BLANKETS

    • Not serious Non-critical

      POSTING SIGNAGE-MAX PATRON LOAD

      Maximum patron load is not posted.

      Correction: Post signage indicating Maximum patron load.

      Code ATCP 76.29(1)(e) - MAX PATRON LOAD

    • Serious Critical

      TELEPHONE ACCESSIBLE

      A telephone or other approved communication technology capable of connecting to emergency services is not working or not present. Pool is closed to the public until the emergency phone is able to dial 911.

      Correction: Provide a working telephone or other technology capable of connecting with emergency services.

      Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE

    • Serious Critical

      FIRST AID KIT-PROVIDED IN POOL AREA

      The first aid kit is missing from the pool area as it is located in the clubhouse basement and is not within 25 feet of the pool enclosure.

      Correction: Provide a first aid kit in the pool area or, if the first aid kit is within 25 feet of the enclosure, post signage that tells where the first aid kit is located.

      Code ATCP 76.27(1)(a) - FIRST AID KIT PRESENT

  6. Jul 31, 2023 Routine · 2 non-critical
    • Not serious Non-critical

      ALKALINITY OUT OF BALANCE

      The total alkalinity is 43.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(4)(d)

    • Not serious Non-critical

      WATER TESTING FREQUENCY - POOLS

      Combined chlorine, alkalinity, CYA not logged. *Sent DII Form

      Correction: Perform water testing in accordance with ATCP 76.18(1).

      Code ATCP 76.18(1)

Source: Waukesha County Environmental Health. History last read Nov 21, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.