RecordWell Data

Baymont-pool

945 GREENWALD CT, Mukwonago, WI 53149 · Waukesha County

22cited violations
5serious tier
7inspections

Establishment

Type
Pool / recreational water (Pool - Simple)
Inspected by
Waukesha County Environmental Health
License / ID
HDEH-AYNPPY
Status
Permitted
Phone
(262) 363-9970
Official record
Waukesha County Environmental Health inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026100
20254164
2024261

Inspections

  1. May 14, 2026 Routine · No items found

    No violations cited.

  2. May 15, 2025 Re-inspection 2 · 1 non-critical
    • Not serious Non-critical

      ALKALINITY

      The total alkalinity is 30 ppm. 5/8: total alkalinity is 39 ppm.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

  3. May 8, 2025 Re-inspection 2 · 2 critical, 1 non-critical, 2 repeat
    • Not serious Non-critical Repeat

      ALKALINITY

      The total alkalinity is 30 ppm. 5/8: total alkalinity is 39 ppm.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Serious Critical

      HAZARDOUS CONDITION

      There is a hazardous condition at the pool. Main drain covers are missing screws.

      Correction: Correct the hazardous condition. Pool shall close until drain covers and installed per manufacturer's requirements.

      Code ATCP 76.34(1) - HAZARDOUS CONDITION AT POOL AREA

    • Serious Critical Repeat

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      The operator of an existing pool does not have the pump curve and drain cover specifications.

      Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  4. Apr 10, 2025 Re-inspection · 1 critical, 5 non-critical, 6 repeat
    • Not serious Non-critical Repeat

      SKIMMERS REPAIRED OR REPLACED AS NEEDED

      Skimmers not repaired or replaced as needed. Skimmer weirs are missing.

      Correction: Repair or replace skimmer, weirs or gutters as needed.

      Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED

    • Not serious Non-critical Repeat

      LABEL, CONSPICUOUS

      Chemical container is not conspicuously labeled. Muriatic acid is not labeled.

      Correction: Provide a conspicuous, easily visible and read label on the chemical container.

      Code ATCP 76.12 (1)(a)

    • Not serious Non-critical Repeat

      ALKALINITY

      The total alkalinity is 30 ppm.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical Repeat

      FIRST AID KIT-EYE WASH SOLUTION

      The first aid kit is missing eye wash solution.

      Correction: Provide eye wash solution for the first aid kit.

      Code ATCP 76.27(1)(b)5. - EYE WASH SOLUTION

    • Not serious Non-critical Repeat

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Serious Critical Repeat

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      The operator of an existing pool does not have the pump curve and drain cover specifications.

      Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  5. Apr 3, 2025 Routine · 1 critical, 5 non-critical, 2 repeat
    • Not serious Non-critical Repeat

      SKIMMERS REPAIRED OR REPLACED AS NEEDED

      Skimmers not repaired or replaced as needed. Skimmer weirs are missing.

      Correction: Repair or replace skimmer, weirs or gutters as needed.

      Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED

    • Not serious Non-critical

      LABEL, CONSPICUOUS

      Chemical container is not conspicuously labeled. Muriatic acid is not labeled.

      Correction: Provide a conspicuous, easily visible and read label on the chemical container.

      Code ATCP 76.12 (1)(a)

    • Not serious Non-critical Repeat

      ALKALINITY

      The total alkalinity is 30 ppm.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical

      FIRST AID KIT-EYE WASH SOLUTION

      The first aid kit is missing eye wash solution.

      Correction: Provide eye wash solution for the first aid kit.

      Code ATCP 76.27(1)(b)5. - EYE WASH SOLUTION

    • Not serious Non-critical

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Serious Critical

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      The operator of an existing pool does not have the pump curve and drain cover specifications.

      Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  6. Apr 4, 2024 Re-inspection · 2 non-critical, 2 repeat
    • Not serious Non-critical Repeat

      SKIMMERS REPAIRED OR REPLACED AS NEEDED

      Skimmers weir doors are missing.

      Correction: Repair or replace skimmer, weirs or gutters as needed.

      Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED

    • Not serious Non-critical Repeat

      POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER

      Pool water is not tested for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.

      Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.

      Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE

  7. Apr 1, 2024 Routine · 1 critical, 3 non-critical
    • Not serious Non-critical

      SKIMMERS REPAIRED OR REPLACED AS NEEDED

      Skimmers weir doors are missing.

      Correction: Repair or replace skimmer, weirs or gutters as needed.

      Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED

    • Not serious Non-critical

      ALKALINITY

      The total alkalinity is 50 ppm.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical

      POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER

      Pool water is not tested for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.

      Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.

      Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE

    • Serious Critical

      WATER CLARITY

      Pool water not transparent and free from cloudiness. Main drain grating and outline not readily visible from pool deck.

      Correction: Close the pool until the pool water is transparent and free from cloudiness and so that main drain grating and outline are readily visible from pool deck.

      Code ATCP 76.16 (2) - CLARITY

Source: Waukesha County Environmental Health. History last read Nov 21, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.