Baymont-whirlpool
945 GREENWALD CT, Mukwonago, WI 53149 · Waukesha County
Establishment
- Type
- Pool / recreational water (Pool - Moderate)
- Inspected by
- Waukesha County Environmental Health
- License / ID
- HDEH-AYNPQD
- Status
- Permitted
- Phone
- (262) 363-9970
- Official record
- Waukesha County Environmental Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 1 | 1 |
| 2025 | 4 | 16 | 6 |
| 2024 | 1 | 5 | 0 |
Inspections
-
May 14, 2026 Routine · 1 critical
-
Serious
Critical
Corrected on site
CO ALARM-POOL EQUIPMENT ROOM
There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.
Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions. Corrected by placing CO alarm in pump room.
Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM
-
Serious
Critical
Corrected on site
-
May 19, 2025 Re-inspection 2 · No items found
No violations cited.
-
May 8, 2025 Re-inspection 2 · 2 critical, 1 non-critical, 3 repeat
-
Not serious
Non-critical
Repeat
ALKALINITY
The total alkalinity is 40 ppm. 5/8: total alkalinity is 33 ppm.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Serious
Critical
Repeat
MAXIMUM BROMINE
The maximum total bromine exceeds 10 ppm. 5/8 bromine is 17.45 ppm.
Correction: Close the pool until the total bromine residual is in compliance with Table ATCP 76.14 Table A.
Code ATCP 76.14(5)(g) -MAXIMUM BROMINE
-
Serious
Critical
Repeat
VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO
The operator of an existing pool does not have the pump curve and drain cover specifications.
Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.
Code ATCP 76.38(1)(b) - PUMP CURVE
-
Not serious
Non-critical
Repeat
-
Apr 10, 2025 Re-inspection · 2 critical, 3 non-critical, 5 repeat
-
Not serious
Non-critical
Repeat
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Skimmers not repaired or replaced as needed. Skimmer weirs are missing.
Correction: Repair or replace skimmer, weirs or gutters as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
Repeat
LABEL, CONSPICUOUS
Chemical container is not conspicuously labeled. Muriatic acid is not labeled.
Correction: Provide a conspicuous, easily visible and read label on the chemical container.
Code ATCP 76.12 (1)(a)
-
Not serious
Non-critical
Repeat
ALKALINITY
The total alkalinity is 40 ppm.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Serious
Critical
Repeat
MAXIMUM BROMINE
The maximum total bromine exceeds 10 ppm.
Correction: Close the pool until the total bromine residual is in compliance with Table ATCP 76.14 Table A.
Code ATCP 76.14(5)(g) -MAXIMUM BROMINE
-
Serious
Critical
Repeat
VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO
The operator of an existing pool does not have the pump curve and drain cover specifications.
Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.
Code ATCP 76.38(1)(b) - PUMP CURVE
-
Not serious
Non-critical
Repeat
-
Apr 3, 2025 Routine · 2 critical, 6 non-critical, 3 repeat
-
Not serious
Non-critical
Repeat
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Skimmers not repaired or replaced as needed. Skimmer weirs are missing.
Correction: Repair or replace skimmer, weirs or gutters as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flowmeter is not being maintained in operating condition.
Correction: Adjust or repair the flowmeter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
LABEL, CONSPICUOUS
Chemical container is not conspicuously labeled. Muriatic acid is not labeled.
Correction: Provide a conspicuous, easily visible and read label on the chemical container.
Code ATCP 76.12 (1)(a)
-
Not serious
Non-critical
SAFETY DATA SHEET
A safety data sheet was not available for a all chemicals used in pool.
Correction: Maintain a safety data sheet for each chemical on site.
Code ATCP 76.12 (4)(b)1. - SAFETY DATA SHEETS
-
Not serious
Non-critical
Repeat
ALKALINITY
The total alkalinity is 40 ppm.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is 570 mV and water has not been tested manually.
Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Serious
Critical
MAXIMUM BROMINE
The maximum total bromine exceeds 10 ppm.
Correction: Close the pool until the total bromine residual is in compliance with Table ATCP 76.14 Table A.
Code ATCP 76.14(5)(g) -MAXIMUM BROMINE
-
Serious
Critical
VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO
The operator of an existing pool does not have the pump curve and drain cover specifications.
Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.
Code ATCP 76.38(1)(b) - PUMP CURVE
-
Not serious
Non-critical
Repeat
-
Apr 1, 2024 Routine · 5 non-critical
-
Not serious
Non-critical
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Skimmers weir door are missing.
Correction: Repair or replace skimmer, weirs or gutters as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flow meter is not being maintained in operating condition.
Correction: Adjust or repair the flow meter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
Corrected on site
ALKALINITY
The total alkalinity is 40 ppm.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER
Whirlpool water is not tested for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.
Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.
Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE
-
Not serious
Non-critical
BIOHAZARD KIT-AVAILABLE
A biohazard kit is not available.
Correction: Provide a biohazard kit for the pool.
Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE
-
Not serious
Non-critical
Source: Waukesha County Environmental Health. History last read Nov 21, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.