  1. May 13, 2025 Re-Inspection · No Reinspection Required

    No violations cited.

  2. May 6, 2025 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      21a - UTENSIL SANITIZATION

      Multi-use food contact surfaces, such as cups, glasses, plates, eating utensils, pots, and pans are not being washed, rinsed and sanitized using approved methods for different guests.

      Correction: All multi-use utensils must be washed, rinsed and sanitized using approved methods, equipment and chemicals OR post signage that 1) notifies the guests that these items have not been sanitized and 2) provides sanitizing instructions. Make non-scented bleach available to guests.

      Code ATCP 72.11(3)(a)

    • Not serious Action taken:

      45a - SLEEPING ROOM SIZE

      The ceiling height in the sleeping room in basement with exterior door is 81 inches and 72 inches. The ceiling height in the other basement sleeping room is 80.75 inches.

      Correction: Sleeping rooms shall have minimum ceiling heights of 7 feet (84 inches) or obtain an approved variance.

      Code ATCP 72.14(2)(b)

    • Not serious Action taken:

      46a - SMOKE DETECTORS

      Smoke detector does not appear to meet UL217 certification. The manufacturer has recalled the unit and specs are not available on the manufacturer's website

      Correction: Provide at least one operational smoke detector that meets UL217 certification and that does not exceed 10 years from the date of manufacture.

      Code ATCP 72.14(2)(c)

    • Not serious Other

      46b - CO DETECTOR PLACEMENT

      Carbon monoxide detector does not appear to meet UL 2034 certification. The manufacturer has recalled the unit and the specs are not available on the manufacturer's website

      Correction: Provide operational carbon monoxide detector that meets UL 2034 certification and is within 10 years of the date of manufacture.

      Code ATCP 72.145(3)

    • Not serious Other

      56a - MISCELLANEOUS

      The guard opposite the handrail on the stairs leading to the basement has 9 inch spacing between vertical cast iron spindles and a 12 inch spacing between cast iron spindle and the wall. The guard extends from the stair tread to the basement ceiling

      Correction: Modify or replace at least the lower 36 inches of the guard to provide spacings of 6 inches or less between posts or added wire and between post and wall OR install a handrail that measures 30-38 inches above the nosing of the tread, with spindle spacings of six inches or less.

      Code ATCP 72.14(1)

  3. Sep 20, 2022 Routine Inspection · No Reinspection Required

    No violations cited.

  4. Sep 23, 2021 Routine Inspection · No Reinspection Required

    No violations cited.

  5. Oct 15, 2020 Pre-Inspection · No Reinspection Required

    No violations cited.