RecordWell Data

Glacier Valley Apartments

6853 Littlemore DR, Madison, WI 53718 · Dane County

19cited violations
0serious tier
4inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
LICSWD-2025-00250
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026290
20252100

Inspections

  1. Aug 28, 2026 Re-Inspection · No Reinspection Required
    • Not serious Action taken: Repeat

      16c - ALKALINITY (Pf) - Not Corrected

      The total alkalinity is 40 ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(5)(d)

    • Not serious Action taken: Repeat

      26r - FIRST AID KIT - SUPPLIES MISSING (Pf) - Not Corrected

      Resuscitation pocket face mask is missing from the first aid kit. Eye Wash is expired on Aug. 2015

      Correction: Provide all the items listed in ATCP 76.27(1)(b) in the first aid kit. 1. Gauze pads. 2. Adhesive bandages. 3. Gauze roller bandage. 4. Adhesive tape. 5. Eye wash. 6. Elastic bandage. 7. Disposable surgical gloves. 8. Resuscitation pocket face mask. 9. Instant cold packs.

      Code ATCP 76.27(1)(b)

  2. Aug 25, 2026 Routine Inspection · Immediate Suspension
    • Not serious Action taken: Pool operator set the skim Corrected on site

      05a - SKIMMER/MAIN DRAIN RATIO (Pf)

      The skimmer to main drain flow ratio is not set correctly.

      Correction: Readjust the flow so that on pool with skimmers, only 20% of the flow comes through the main drain and 80% comes through the skimmers. On a gutter pool, 75% of the required recirculation flow shall be through the gutter and 25% through the main drain. For reverse flow pools, 100% recirculation must be through gutter or skimmers.

      Code ATCP 76.11(2)(a)

    • Not serious Action taken:

      09a - FLOW METER (P

      The flow meter is not functional.

      Correction: Repair, replace, or install the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken:

      11e - SDS AVAILABILITY (Pf)

      Safety data sheets are not available for all chemicals used in the facility.

      Correction: Provide safety data sheets for all chemicals used in the facility.

      Code ATCP 76.12(4)(b)

    • Not serious Action taken:

      14e - WATER POTENTIAL ORP (Pf)

      The water potential was 629 mV at the time of the inspection.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.

      Code ATCP 76.14(5)(a)

    • Not serious Action taken:

      16c - ALKALINITY (Pf)

      The total alkalinity is 50 ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(5)(d)

    • Not serious Action taken:

      26m - TELEPHONE - NO CONNECTION TO EMERGENCY SERVICES (P)

      The pool phone does not directly connect to emergency services. The push button emergency phone calls emergency dispatch services, neither are they able to hear anyone from the phone nor can anyone hear them from the emergency dispatch center.

      Correction: Provide a telephone capable of connecting with emergency services at all times during pool operation or apply for a variance. Close the pool until the emergency telephone is able to connect to emergency operators.

      Code ATCP 76.26(2)(a)

    • Not serious Action taken:

      26r - FIRST AID KIT - SUPPLIES MISSING (Pf)

      Resuscitation pocket face mask is missing from the first aid kit. Eye Wash is expired on Aug. 2015

      Correction: Provide all the items listed in ATCP 76.27(1)(b) in the first aid kit. 1. Gauze pads. 2. Adhesive bandages. 3. Gauze roller bandage. 4. Adhesive tape. 5. Eye wash. 6. Elastic bandage. 7. Disposable surgical gloves. 8. Resuscitation pocket face mask. 9. Instant cold packs.

      Code ATCP 76.27(1)(b)

  3. May 27, 2025 Pre-Inspection · No Reinspection Required
    • Not serious Action taken:

      16b - CYANURIC ACID (Pf)

      The cyanuric acid concentration is ~35 ppm.

      Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.

      Code ATCP 76.14(5)(b)

    • Not serious Action taken:

      16c - ALKALINITY (Pf)

      The total alkalinity is 260 ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(5)(d)

    • Not serious Action taken:

      26g - BREATH HOLDING PROHIBITION - SIGNAGE

      Breath holding prohibition is not posted or communicated to patrons.

      Correction: Provide signage or otherwise communicate to patrons that activites involving prolonged breath holding are prohibited.

      Code ATCP 76.29(1)(f)

    • Not serious Action taken:

      26s - BLANKETS MISSING (Pf)

      1 conventional or emergency blankets are not available in the pool area. Only one (1) safety blanket is provided.

      Correction: Provide 2 conventional or emergency blankets in the pool area.

      Code ATCP 76.27(1)(3)

    • Not serious Action taken:

      29d - DECK MAINTENANCE AND CLEANING (Pf)

      The pool deck area at the entrance into the pool has a crack, is not maintained in good repair.

      Correction: Maintain in good repair and clean and sanitize the deck according to ATCP 76.33 (1)(b).

      Code ATCP 76.33(1)(b)

  4. May 27, 2025 Re-Inspection · No Reinspection Required
    • Not serious Action taken:

      16b - CYANURIC ACID (Pf) - Not Corrected

      The cyanuric acid concentration is 35 ppm.

      Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.

      Code ATCP 76.14(5)(b)

    • Not serious Action taken:

      16c - ALKALINITY (Pf) - Not Corrected

      The total alkalinity is 230 ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(5)(d)

    • Not serious Action taken:

      26g - BREATH HOLDING PROHIBITION - SIGNAGE - Not Corrected

      Breath holding prohibition is not posted or communicated to patrons.

      Correction: Provide signage or otherwise communicate to patrons that activites involving prolonged breath holding are prohibited.

      Code ATCP 76.29(1)(f)

    • Not serious Action taken:

      26s - BLANKETS MISSING (Pf) - Not Corrected

      1 conventional or emergency blankets are not available in the pool area. Only one (1) safety blanket is provided

      Correction: Provide 2 conventional or emergency blankets in the pool area.

      Code ATCP 76.27(1)(3)

    • Not serious Action taken:

      29d - DECK MAINTENANCE AND CLEANING (Pf) - Not Corrected

      The pool deck area at the entrance into the pool has a crack, is not maintained in good repair.

      Correction: Maintain in good repair and clean and sanitize the deck according to ATCP 76.33 (1)(b).

      Code ATCP 76.33(1)(b)

Source: Public Health Madison & Dane County. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.