Birchcliff Resort
4149 RIVER RD, Wisconsin Dells, WI 53965 · Adams County
Establishment
- Type
- Lodging (Tourist Rooming House - 20 - 39 TRH)
- Inspected by
- Adams County Health & Human Services
- License / ID
- KPAL-9MFPGA
- Status
- Permitted
- Phone
- (608) 254-7515
- Official record
- Adams County Health & Human Services inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 10 | 3 |
| 2025 | 1 | 3 | 0 |
| 2024 | 1 | 1 | 0 |
| 2023 | 1 | 1 | 0 |
Inspections
-
May 7, 2026 Routine · 10 non-critical
-
Serious
Critical
POWTS access covers
The POWTS access cover was observed unlocked.
Correction: Locked or secure the POWTS access cover to prevent general access by the public.
Code ATCP 72.17(3)(b)
-
Serious
Critical
First floor sleeping room - 2 exits provided
The first floor used for sleeping was not provided with at least 2 separate exits.
Correction: Provide at least 2 separate exits from the first floor used for sleeping or discontinue sleeping from that floor. See notes section for specific units.
Code ATCP 72.18(4)(b)
-
Serious
Critical
Second floor sleeping room - 2 exits provided
The second floor used for sleeping was not provided with at least 2 separate exits.
Correction: Provide at least 2 separate exits from the second floor used for sleeping or discontinue sleeping from that floor. Unit 31 "cubby bedroom" does not have a window along with other units not having appropriate sized window - see notes section for specific units.
Code ATCP 72.18(4)(c)
-
Not serious
Priority Foundation
Smoke alarm installed outside each separate sleeping area
some units missing a smoke alarm within 21 feet walking distance outside sleeping rooms.
Correction: Provide a smoke alarm outside of each separate sleeping area, within 21 feet of any door to a sleeping room. See notes section.
Code ATCP 72.18(11)(b)2.
-
Not serious
Priority Foundation
Smoke alarm installed in each sleeping room
Some sleeping rooms are missing smoke alarms.
Correction: Provide a smoke alarm within each sleeping room. See notes section.
Code ATCP 72.18(11)(b)3.
-
Not serious
Priority Foundation
Windows used for exiting - platform for windows > 46 inches above floor
Some units have appropriately sized egress window but is located higher than 46 inches from the floor and window used for exiting does not have a permanent platform or fixture installed.
Correction: Provide a permanent platform or fixture that is at least 20 inches wide and 9 inches deep is located no more than 46 inches directly below the clear opening, or provide a different exit, or discontinue sleeping from that floor. See notes section for specific units.
Code ATCP 72.18(4)(g)5.
-
Not serious
Priority Foundation
Building evacuation diagram (TRH) - posted or provided
The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.
Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.
Code ATCP 72.18(6)(b)1.
-
Not serious
Non-critical
Ceiling height >= 7'
At least 50 percent of the second level "cubby bedroom" in unit 31 sleeping room’s floor area does not have a ceiling height of at least 7 feet.
Correction: Remove beds or apply for a variance.
Code ATCP 72.18(3)(a)
-
Not serious
Non-critical
Exterior of building maintained
Several windows, especially in older units, are in poor condition and should be repaired or replaced.
Correction: Maintain the exterior of the building in good repair.
Code ATCP 72.19(1)(c)1.
-
Not serious
Non-critical
Pest control - openable windows screened
Multiple windows throughout facility missing window screens or screens need repair.
Correction: All openable windows within in individually keyed units need to have a screen. See notes section for specific units.
Code ATCP 72.19(2)(a)3.b.
-
Serious
Critical
-
Jun 17, 2025 Routine · 3 non-critical
-
Not serious
Non-critical
SMOKE DETECTORS - REQUIREMENT
Smoke detectors are absent or not in working order in #39 (battery is missing)
Correction: Provide operational smoke detectors in all sleeping rooms and required locations.
Code ATCP 72.14 (2) (c)
-
Not serious
Non-critical
WINDOW SCREENING
Window screen missing from the following #9.
Correction: Provide screening on all windows that can be opened to the outside.
Code ATCP 72.14 (2) (e)
-
Not serious
Non-critical
GENERAL MAINTENANCE
Septic cover not locked by unit 33.
Correction: Maintained establishment in a manner conducive to the health, comfort and safety of its guests.
Code [C] ATCP 72.15 (1)
-
Not serious
Non-critical
-
Jun 18, 2024 Routine · 1 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
WINDOW SCREENING
Window screen missing from bedroom windows.
Correction: Provide screening on all windows that can be opened to the outside.
Code ATCP 72.14 (2) (e)
-
Not serious
Non-critical
Repeat
-
Jun 6, 2023 Routine · 1 non-critical
-
Not serious
Non-critical
WINDOW SCREENING
Window screen missing from bedroom in cabin 37.
Correction: Provide screening on all windows that can be opened to the outside.
Code ATCP 72.14 (2) (e)
-
Not serious
Non-critical
Source: Adams County Health & Human Services. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.