  1. Apr 14, 2026 Routine · 5 non-critical
    • Serious Critical

      Basement or ground floor sleeping room - 2 exits provided

      The basement or ground floor used for sleeping was not provided with at least 2 separate exits.

      Correction: Provide at least 2 separate exits from the basement or ground floor used for sleeping or discontinue sleeping from that floor.

      Code ATCP 72.18(4)(ar)

    • Not serious Priority Foundation

      Bunk beds - 2.5' spacing between beds

      A vertical separation of less than 2.5 feet measured from the top of the lower mattress to the bottom of the frame of the upper bunk bed was observed.

      Correction: Provide a vertical separation of at least 2.5 feet measured from the top of the lower mattress to the bottom of the frame of the upper bunk bed.

      Code ATCP 72.18(3)(d)2.

    • Not serious Priority Foundation

      Bunk beds - 2.5' spacing between top bed and ceiling

      A free space of less than 2.5 feet was observed above the mattress of the upper bunk beds..

      Correction: Provide a free space of at least 2.5 feet above the mattress of the upper bunk beds.

      Code ATCP 72.18(3)(d)3.

    • Not serious Priority Foundation

      Second floor sleeping room - exit types

      The provided exits from the second floor used for sleeping did not meet the following: There is no permanent platform (at least 20" x 9") below the window to make the lowest point of the window opening less than 46" above the platform.

      Correction: Correct the window heigh and provide at least 2 separate exits from the second floor used for sleeping or discontinue sleeping from that floor.

      Code ATCP 72.18(4)(c)1.2.

    • Not serious Priority Foundation

      Building evacuation diagram (TRH) - posted or provided

      The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.

      Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.

      Code ATCP 72.18(6)(b)1.

  2. Mar 12, 2025 Pre-inspection · No items found

    No violations cited.