RecordWell Data

Cornflower Blue Ridge

2418 RIDGEWOOD DR, Friendship, WI 53934 · Adams County

4cited violations
1serious tier
1inspections

Establishment

Type
Lodging (Tourist Rooming House - 1 TRH)
Inspected by
Adams County Health & Human Services
License / ID
VELT-DUFRD7
Status
Permitted
Phone
(773) 919-7819
Official record
Adams County Health & Human Services inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026141

Inspections

  1. May 28, 2026 Pre-inspection · 4 non-critical
    • Serious Critical

      Second floor sleeping room - 2 exits provided

      One bedroom on second level does not have a window with a 20 by 24 inch opening. The other bedroom has a window that appears to meet egress requirements.

      Correction: Provide at least 2 separate exits from the second floor used for sleeping or discontinue sleeping from that floor. If windows are relied on for second exit, each sleeping room needs a code complying egress window.

      Code ATCP 72.18(4)(c)

    • Not serious Priority Foundation

      Handrail on stairs > 3 risers

      The handrail does not extend for the duration of the flight of stairs leading to second level..

      Correction: At least one handrail shall be provided for a flight of stairs with more than 3 risers. Extend hand railing.

      Code ATCP 72.18(2)(a)1.

    • Not serious Priority Foundation

      Guards provided on stairs > 3 risers

      guards on stair case do not extend the entire duration of the flight of stairs.

      Correction: Guards shall be provided on all open sides of stairs consisting of more than 3 risers. The stairs leading to second level consists of more than 3 risers and should have guards extended at the top.

      Code ATCP 72.18(2)(b)1.

    • Not serious Priority Foundation

      Building evacuation diagram (TRH) - posted or provided

      The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.

      Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.

      Code ATCP 72.18(6)(b)1.

Source: Adams County Health & Human Services. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.