RecordWell Data

Camp Lake Mason

4035 1ST LN, Briggsville, WI 53920 · Adams County

15cited violations
7serious tier
5inspections

Establishment

Type
Pool / recreational water (Pool - Simple)
Inspected by
Adams County Health & Human Services
License / ID
VELT-CR9P9E
Status
Permitted
Phone
(608) 432-5340
Official record
Adams County Health & Human Services inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026163
2025273
2024121
2023100

Inspections

  1. Jun 10, 2026 Routine · 3 critical, 3 non-critical, 1 repeat
    • Not serious Non-critical

      BIOHAZARD KIT-AVAILABLE

      A biohazard kit is not available.

      Correction: Provide a biohazard kit for the pool.

      Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE

    • Not serious Non-critical

      SOAP-PROVIDED

      Soap not provided in permanently-installed dispensing device.

      Correction: Provide soap in a permanently-installed dispensing device.

      Code ATCP 76.33 (2)(e)1. - SOAP

    • Not serious Non-critical

      VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT

      The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.

      Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.

      Code ATCP 76.38(2)(a) - DRAIN COVER LOG

    • Serious Critical Corrected on site

      MINIMUM DISINFECTANT RESIDUAL

      Minimum disinfectant or sanitizer level is [.8 ] for [chlorine].

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

    • Serious Critical

      WATER CLARITY

      Pool water not transparent and free from cloudiness. Main drain grating and outline not readily visible from pool deck.

      Correction: Close the pool until the pool water is transparent and free from cloudiness and so that main drain grating and outline are readily visible from pool deck.

      Code ATCP 76.16 (2) - CLARITY

    • Serious Critical Repeat

      DRINKING FOUNTAIN PROVIDED

      There is no drinking fountain provided.

      Correction: Provide a drinking fountain within 300 feet walking distance.

      Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED

  2. May 30, 2025 Re-inspection · 1 critical, 2 non-critical, 3 repeat
    • Not serious Non-critical Repeat

      CYANURATES 30 PPM LIMIT

      The cyanuric acid concentration is over 30 ppm.

      Correction: Lower the water cyanuric acid concentration to 30 ppm or lower.

      Code ATCP 76.14(5)(b)1 - MAXIMUM CYANURIC

    • Not serious Non-critical Repeat

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Serious Critical Repeat

      DRINKING FOUNTAIN PROVIDED

      There is no drinking fountain provided. Operator has plans to install drinking fountain.

      Correction: Provide a drinking fountain within 300 feet walking distance.

      Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED

  3. May 29, 2025 Routine · 2 critical, 2 non-critical
    • Not serious Non-critical

      CYANURATES 30 PPM LIMIT

      The cyanuric acid concentration is over 30 ppm.

      Correction: Lower the water cyanuric acid concentration to 30 ppm or lower.

      Code ATCP 76.14(5)(b)1 - MAXIMUM CYANURIC

    • Not serious Non-critical

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Serious Critical

      MAXIMUM CHLORINE

      The maximum chlorine residual exceeds 10 ppm.

      Correction: Close the pool until the chlorine residual is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(f) - MAXIMUM FREE CHLORINE

    • Serious Critical

      DRINKING FOUNTAIN PROVIDED

      There is no drinking fountain provided. Operator has plans to install drinking fountain.

      Correction: Provide a drinking fountain within 300 feet walking distance.

      Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED

  4. May 29, 2024 Routine · 1 critical, 1 non-critical
    • Not serious Non-critical

      ALKALINITY

      The total alkalinity is [210 ppm ].

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Serious Critical

      MINIMUM DISINFECTANT RESIDUAL

      Minimum disinfectant or sanitizer level is 1.0 ppm.

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

  5. May 24, 2023 Pre-inspection · No items found

    No violations cited.

Source: Adams County Health & Human Services. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.