RecordWell Data

Snug Harbor Hmownrs Assoc

2343 W 18TH DR, Friendship, WI 53934 · Adams County

21cited violations
7serious tier
5inspections

Establishment

Type
Pool / recreational water (Swimming)
Inspected by
Adams County Health & Human Services
License / ID
HSAT-7QWQ6A
Status
Permitted
Phone
(608) 548-1058
Official record
Adams County Health & Human Services inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026283
2025162
2024142
2023130

Inspections

  1. Jul 16, 2026 Re-inspection · 1 critical, 1 non-critical, 2 repeat
    • Not serious Non-critical Repeat

      SPARE STRAINER BASKET OR SCREEN AVAILABLE

      Spare strainer or screen not available

      Correction: Provide a spare strainer or screen

      Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN

    • Serious Critical Repeat

      OPERATOR KNOWLEDGE-MONTHLY TESTING

      The person responsible is not able to describe how monthly testing is performed.

      Correction: Ensure that operator can describe how monthly testing is performed.

      Code ATCP 76.13 (1)(c)2.d - MONTHLY TESTING

  2. Jul 15, 2026 Routine · 2 critical, 4 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      SPARE STRAINER BASKET OR SCREEN AVAILABLE

      Spare strainer or screen not available

      Correction: Provide a spare strainer or screen

      Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN

    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flowmeter is not being maintained in operating condition. Flowmeter is stuck

      Correction: Adjust or repair the flowmeter.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical

      CHEMICAL FEEDERS USED-CAPABLE OF PROVIDING REQUIRED RESIDUAL

      [Chemical] feeder is not capable of providing required chemical residual. Chlorine pump is not working properly.

      Correction: Install a chemical feeder that is capable of providing the required chemical residual (plan review may be required).

      Code ATCP 76.13(1)(b)3. - CAPABLE OF PROVIDING REQUIRED RESIDUAL

    • Not serious Non-critical

      ELECTRONIC MONITORING WATER POTENTIAL

      The water potential ("ORP") is [ 476] mV and water has not been tested manually.

      Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.

      Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL

    • Serious Critical

      OPERATOR KNOWLEDGE-MONTHLY TESTING

      The person responsible is not able to describe how monthly testing is performed.

      Correction: Ensure that operator can describe how monthly testing is performed.

      Code ATCP 76.13 (1)(c)2.d - MONTHLY TESTING

    • Serious Critical

      MINIMUM DISINFECTANT RESIDUAL

      Chlorine level was 0.

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

  3. Jul 16, 2025 Routine · 2 critical, 4 non-critical, 2 repeat
    • Not serious Non-critical

      SPARE STRAINER BASKET OR SCREEN AVAILABLE

      Spare strainer or screen not available

      Correction: Provide a spare strainer or screen

      Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN

    • Not serious Non-critical

      INTERLOCK-LOG KEPT

      A log of the monthly interlock tests is not being kept.

      Correction: Keep a log of monthly interlock tests.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical Repeat

      POSTING SIGNAGE-MAX PATRON LOAD

      Maximum patron load is not posted.

      Correction: Post signage indicating Maximum patron load.

      Code ATCP 76.29(1)(e) - MAX PATRON LOAD

    • Serious Critical Repeat

      CO ALARM-POOL EQUIPMENT ROOM

      There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.

      Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.

      Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM

    • Serious Critical

      HAZARDOUS CONDITION

      There is a hazardous condition at the pool. The railing for the ladders and steps are very loose..

      Correction: Correct the hazardous condition by tightening the railings.

      Code ATCP 76.34(1) - HAZARDOUS CONDITION AT POOL AREA

  4. Jul 30, 2024 Routine · 2 critical, 2 non-critical
    • Not serious Non-critical

      COMBINED CHLORINE TEST

      Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level.

      Correction: Test pool water at least twice a week for the combined chlorine level.

      Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,

    • Not serious Non-critical Corrected on site

      POSTING SIGNAGE-MAX PATRON LOAD

      Maximum patron load is not posted.

      Correction: Post signage indicating Maximum patron load.

      Code ATCP 76.29(1)(e) - MAX PATRON LOAD

    • Serious Critical Corrected on site

      MAXIMUM CHLORINE

      The maximum chlorine residual exceeds 10 ppm.

      Correction: Close the pool until the chlorine residual is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(f) - MAXIMUM FREE CHLORINE

    • Serious Critical

      CO ALARM-POOL EQUIPMENT ROOM

      There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.

      Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.

      Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM

  5. Jul 11, 2023 Routine · 3 non-critical
    • Not serious Non-critical

      FLOWMETER, VALVES AND GAUGES NOT FUNCTIONAL

      Flowmeter not functional.

      Correction: Repair or replace the specified equipment so an accurate reading can be recorded.

      Code ATCP 76.11(5)

    • Not serious Non-critical

      WATER TESTING FREQUENCY - POOLS

      The water testing frequency for combined chlorine is not in compliance with ATCP 76.18(1).

      Correction: Perform water testing in accordance with ATCP 76.18(1). Test for combined chlorine twice a week.

      Code ATCP 76.18(1)

    • Not serious Non-critical

      EQUIPMENT NOT MAINTAINED

      pool stairs on deep end are loose and need tightening.

      Correction: Repair and maintain all equipment pursuant to ATCP 76.33(1)(e).

      Code ATCP 76.33(1)(e)

Source: Adams County Health & Human Services. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.