RecordWell Data

Junction Point Condominium Association INC

301 HARBOUR TOWN DR, Madison, WI 53717 · Dane County

12cited violations
0serious tier
10inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
71694-78565
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026160
2025150
2023110
2021100
2018100
2017100
2015100
2014200
2012100

Inspections

  1. Jan 22, 2026 Routine Inspection · No Reinspection Required
    • Not serious Action taken: ADDENDUM: new 2HP pump ins Corrected on site

      08a - RECIRCULATION RATE - SWIM/COMBO (Pf)

      The swimming pool or combination pool has a maximum turnover rate of greater than 6 hours.

      Correction: Immediately adjust or repair the equipment so the turnover rate does not exceed 6 hours.

      Code ATCP 76.11(4)(c)

    • Not serious Action taken:

      11e - SDS AVAILABILITY (Pf)

      Safety data sheets are not available for all chemicals used in the facility.

      Correction: Provide safety data sheets for all chemicals used in the facility.

      Code ATCP 76.12(4)(b)

    • Not serious Action taken:

      21d - READABLE CHART

      There is no readable chart that describes the piping, valves, and direction of water flow.

      Correction: Labels, tags, or color coding shall correspond to a conspicuously posted, easily read chart that explains the system.

      Code ATCP 76.11(5m)(b)

    • Not serious Action taken:

      29b - BASIN MAINTENANCE AND REPAIR

      There is a visible rust stain on the pool basin near the main drain covers.

      Correction: Maintain the pool basin in a clean, sanitary condition and free from cracks and defects.

      Code ATCP 76.33(1)(a)

    • Not serious Action taken:

      29d - DECK MAINTENANCE AND CLEANING (Pf)

      The pool areas are not maintained in good repair or are not being cleaned and disinfected regularly. Pool deck is chipping and there are loose bits on the deck.

      Correction: Maintain in good repair and clean and sanitize the deck according to ATCP 76.33 (1)(b).

      Code ATCP 76.33(1)(b)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf)

      No documentation is available on site for VGBA equalizer covers showing make, model, gallons per minute rating, life span, and installation date. VGBA log indicates that the equalizer covers were installed in 2017 and had a 5 year lifespan (expired in 2022).

      Correction: Install new equalizer covers and maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.

      Code ATCP 76.38

  2. Feb 26, 2025 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      09a - FLOW METER

      The electronic flow meter is not functional and the analog flowmeter's markings are hard to read.

      Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken: sanitarian recommended pro

      11b - CHEMICAL - STORAGE

      Chemicals are improperly stored in accordance with ATCP 76.12(2). Acid containers stored directly adjacent to large chlorine bin without any form of overspill protection.

      Correction: Store chemicals in accordance with ATCP 76.12(2).

      Code ATCP 76.12(2)

    • Not serious Action taken:

      26s - BIOHAZARD SAFETY KIT

      No biohazard safety kit is located on the premises.

      Correction: Provide a biohazard safety kit at the first aid station.

      Code ATCP 76.27(2)

    • Not serious Action taken:

      29b - BASIN DEFECTS

      There is a rust stain on the pool basin near the main drain covers.

      Correction: Repair the pool basin so it is finished and easily cleanable.

      Code ATCP 76.33(1)(a)

    • Not serious Other

      34e - VGBA COVERS

      VGBA equalizer covers' lifespan may have expired in 2022. No documentation is available on site for VGBA equalizer covers showing make/model, installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  3. Sep 28, 2023 Routine Inspection · No Reinspection Required
    • Not serious Other

      34e - VGBA COVERS

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date. Drain covers were replaced in 2022.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  4. Apr 23, 2021 Routine Inspection · No Reinspection Required

    No violations cited.

  5. Mar 1, 2018 Routine Inspection · No Reinspection Required

    No violations cited.

  6. Jun 29, 2017 Routine Inspection · No Reinspection Required

    No violations cited.

  7. Nov 5, 2015 Routine Inspection · No Reinspection Required

    No violations cited.

  8. Dec 15, 2014 Routine Inspection · No Reinspection Required

    No violations cited.

  9. Feb 11, 2014 Routine Inspection · No Reinspection Required

    No violations cited.

  10. Dec 5, 2012 Routine Inspection · No Reinspection Required

    No violations cited.

Source: Public Health Madison & Dane County. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.