  1. Jul 21, 2026 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      05b - WATER LEVEL (Pf)

      The pool water level is not adequate for continuous effective surface skimming. Water level is too low.

      Correction: Adjust the water level until the skimming of the water surface is adequate (mid-line on the skimmer entrance). Water levels in pools with skimmers shall be maintained at a level such that the weir is half submerged or in the case of a floating weir, used according to manufacturer's directions. Gutters shall have a continuous water supply over the gutter.

      Code ATCP 76.11(2)(a) and ATCP 76.19(3)

    • Not serious Action taken:

      11e - SDS AVAILABILITY (Pf)

      Safety data sheets are not available for all chemicals used in the facility.

      Correction: Provide safety data sheets for all chemicals used in the facility.

      Code ATCP 76.12(4)(b)

    • Not serious Action taken:

      16b - CYANURIC ACID (Pf)

      The cyanuric acid concentration is 40ppm.

      Correction: Lower the concentration of cyanuric acid to 30 ppm or lower and maintain.

      Code ATCP 76.14(5)(b)

    • Not serious Action taken:

      20e - WATER TESTING FREQUENCY - WITH ELECTRONIC MONITORING DEVICE (Pf)

      The water testing frequency for pH and free chlorine is not in compliance with ATCP 76.18(3). ORP at 640mV at time of inspection and pool records indicate that the pool is tested once daily.

      Correction: Perform water testing in accordance with ATCP 76.18(3). If ORP is not within range 650-900mV, then the pool must be tested 2x/day for free chlorine and pH.

      Code ATCP 76.18(3)

    • Not serious Action taken:

      27d - SIGNAGE - NO DIVING (Pf)

      'NO DIVING' is not posted in the pool rules for a pool that is 200 square feet in area or greater without an approved diving well configuration.

      Correction: Post approved signage with letters at least 4 inches in height.

      Code ATCP 76.29(1)(d)

  2. Aug 27, 2025 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      09a - FLOW METER (P

      The flow meter is not functional or installed properly.

      Correction: Repair, replace, or install the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken: Sanitarian recommended ins

      11b - CHEMICAL - STORAGE (P)(Pf)

      Chemicals are improperly stored in accordance with ATCP 76.12(2). No overspill protection to prevent chlorine from mixing with acid.

      Correction: Store chemicals in accordance with ATCP 76.12(2).

      Code ATCP 76.12(2)

    • Not serious Action taken:

      11e - SDS AVAILABILITY (Pf)

      Safety data sheets are not available for all chemicals used in the facility.

      Correction: Provide safety data sheets for all chemicals used in the facility.

      Code ATCP 76.12(4)(b)

    • Not serious Action taken:

      16b - CYANURIC ACID (Pf)

      The cyanuric acid concentration is 60ppm.

      Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.

      Code ATCP 76.14(5)(b)

    • Not serious Action taken:

      20c - WATER TESTING - POOLS (Pf)

      The water testing frequency for cyanuric acid and combined chlorine is not in compliance with ATCP 76.18(1).

      Correction: Perform water testing in accordance with ATCP 76.18(1). Test/record cyanuric acid 1x/week and combined chlorine 2x/week.

      Code ATCP 76.18(1)

    • Not serious Action taken: sanitarian emailed signage

      26g - BREATH HOLDING PROHIBITION - SIGNAGE

      Breath holding prohibition is not posted or communicated to patrons.

      Correction: Provide signage or otherwise communicate to patrons that activities involving prolonged breath holding are prohibited.

      Code ATCP 76.29(1)(f)

  3. Aug 26, 2024 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      20c - WATER TESTING - POOLS

      The water testing frequency for combined chlorine is not in compliance with ATCP 76.18(1).

      Correction: Perform water testing in accordance with ATCP 76.18(1). Test/record results for combined chlorine reading 2x/week.

      Code ATCP 76.18(1)

  4. Jul 18, 2023 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      05a - SKIMMER/MAIN DRAIN RATIO

      The skimmer to main drain flow ratio is not set correctly. Main drain valve observed full open.

      Correction: Readjust the flow so that on skimmer pool, only 20% of the flow comes through the main drain and 80% comes through the skimmers. On a gutter pool, 75% of the required recirculation flow shall be through the gutter and 25% through the main drain.

      Code ATCP 76.11(2)(a)

    • Not serious Action taken:

      20c - WATER TESTING - POOLS

      The water testing frequency for combined chlorine and cyanuric acid is not in compliance with ATCP 76.18(1).

      Correction: Perform water testing in accordance with ATCP 76.18(1). Test/record readings for combined chlorine 2x/week and cyanuric acid 1x/week (if using stabilizer).

      Code ATCP 76.18(1)

    • Not serious Action taken:

      26s - BIOHAZARD SAFETY KIT

      No biohazard safety kit is located on the premises.

      Correction: Provide a biohazard safety kit at the first aid station.

      Code ATCP 76.27(2)

    • Not serious Action taken: pool will be repaired in t

      29f - DEPTH MARKINGS VISIBLE

      The depth markings at the 5'0'' deep end of the pool wall are fading or worn and in need of replacement.

      Correction: Repair the markings so they are clearly visible and readable.

      Code ATCP 76.33(1)(b)

    • Not serious Other

      34e - VGBA COVERS

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  5. Aug 17, 2021 Re-Inspection · No Reinspection Required

    No violations cited.

  6. Aug 12, 2021 Routine Inspection · Reinspection Required

    No violations cited.

  7. Jul 30, 2019 Routine Inspection · No Reinspection Required

    No violations cited.

  8. Jul 17, 2018 Routine Inspection · No Reinspection Required

    No violations cited.

  9. Aug 15, 2017 Routine Inspection · No Reinspection Required

    No violations cited.

  10. Aug 15, 2016 Routine Inspection · No Reinspection Required

    No violations cited.

  11. Aug 3, 2015 Routine Inspection · No Reinspection Required

    No violations cited.

  12. Aug 6, 2014 Routine Inspection · No Reinspection Required

    No violations cited.

  13. Jul 24, 2013 Routine Inspection · No Reinspection Required

    No violations cited.

  14. Jul 11, 2012 Routine Inspection · No Reinspection Required

    No violations cited.

Source: Public Health Madison & Dane County. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.