RecordWell Data

Mazomanie Municipal Pool

318 PARK ST, Mazomanie, WI 53560 · Dane County

55cited violations
0serious tier
16inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
73399-81629
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20263300
20252100
20242150
2021100
2019100
2017100
2016100
2015100
2014200
2013100
2012100

Inspections

  1. Jul 10, 2026 Re-Inspection · No Reinspection Required

    No violations cited.

  2. Jun 26, 2026 Re-Inspection · Reinspection Required
    • Not serious Action taken:

      13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P) - Not Corrected

      Operator cannot demonstrate knowledge or provide documentation of interlock system per requirements in ATCP 76.13(1)(c).

      Correction: Operator must be able to demonstrate knowledge and provide documentation of interlock system. Interlock must be tested at least once a month, with date, results and initials of tester.

      Code ATCP 76.13(1)(c)

    • Not serious Action taken:

      14a - CHLORINE TOO LOW (P) - Not Corrected

      The chlorine residual was 0.2 at the time of the inspection.

      Correction: Close the pool and raise the chlorine residual to 1-10 ppm. Call inspector to schedule a reopening inspection.

      Code ATCP 76.14(4)(a)

    • Not serious Action taken:

      14e - WATER POTENTIAL ORP (Pf) - Not Corrected

      The water potential was 331 mV at the time of the inspection. Operator states citric acid was added yesterday to address staining issues, which might be affecting ORP functionality.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.

      Code ATCP 76.14(5)(a)

    • Not serious Action taken:

      16d - COMBINED CHLORINE (Pf) - Not Corrected

      The operator does not have a combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken:

      20e - WATER TESTING FREQUENCY - WITH ELECTRONIC MONITORING DEVICE (Pf) - Not Corrected

      The water testing frequency for pH, combined chlorine, cyanuric acid, and alkalinity is not in compliance with ATCP 76.18(3).

      Correction: Perform water testing in accordance with ATCP 76.18(3). Test pH once a day, combined chlorine twice a week, cyanuric acid once a week, and alkalinity once a week.

      Code ATCP 76.18(3)

    • Not serious Action taken:

      21b - BACKFLOW - HOSE BIBBS (P) - Not Corrected

      The hose bibb by the acid storage room and in the women's locker room is not protected against backsiphonage.

      Correction: Install a hose bibb atmospheric vacuum breaker that meets the ASSE 1011 standard on the hose bibb.

      Code ATCP 76.33(1)(d)

    • Not serious Action taken:

      21d - READABLE CHART - Not Corrected

      There is no readable chart that describes the piping, valves, and direction of water flow.

      Correction: Labels, tags, or color coding shall correspond to a conspicuously posted, easily read chart that explains the system.

      Code ATCP 76.11(5m)(b)

    • Not serious Action taken:

      26h - RESCUE EQUIPMENT - ACCESSIBLE, GOOD REPAIR, SIZED (P) - Not Corrected

      Ring buoy rope is not correctly connected to the buoy itself; rope is on a carabiner. Buoy is not required as guards always have rescue tubes.

      Correction: Connect rope directly to buoy or remove buoy from pool area.

      Code ATCP 76.26(1)

    • Not serious Action taken:

      26p - EMERGENCY NUMBERS AND ADDRESS (Pf) - Not Corrected

      The emergency numbers are not posted near the designated emergency phone.

      Correction: Post the emergency and non-emergency numbers near the designated emergency phone.

      Code ATCP 76.26(2)(d)

    • Not serious Action taken:

      26r - FIRST AID KIT - SUPPLIES MISSING (Pf) - Not Corrected

      Elastic bandage and non-expired eye wash are missing from the first aid kit.

      Correction: Provide all the items listed in ATCP 76.27(1)(b) in the first aid kit. 1. Gauze pads. 2. Adhesive bandages. 3. Gauze roller bandage. 4. Adhesive tape. 5. Eye wash. 6. Elastic bandage. 7. Disposable surgical gloves. 8. Resuscitation pocket face mask. 9. Instant cold packs.

      Code ATCP 76.27(1)(b)

    • Not serious Action taken: Wipes ordered per operator

      26t - BIOHAZARD SAFETY KIT (Pf) - Not Corrected

      The biohazard safety kit is missing sanitizing hand wipes.

      Correction: Provide a biohazard safety kit with the items listed in ATCP 76.27(2)(b) at the first aid station or on the premise. 1. Scoop and spatula. 2. Sanitizing hand wipes. 3. Sanitizing surface wipes. 4. Neoprene gloves. 5. Paper toweling. 6. Biohazard disposal bag at least 24"X24". 7. Twist tie or other effective means to close the bag. 8. Biohazard sorbent. 9. Storage case.

      Code ATCP 76.27(2)

    • Not serious POOL SLIDES AND WATERSLIDES. For the plu

      27h - SIGNAGE - SLIDE RULES - Not Corrected

      The letters for the pool slide rules are not at least 1 inch in height, and the water depth number is worn away.

      Correction: Provide an approved sign.

      Code ATCP 76.29(2)

    • Not serious Action taken:

      28e -REPORTS AND RECORDS (Pf) - Not Corrected

      Operator is not using department-provided daily testing form.

      Correction: Use department-provided daily form and keep the following records available for review. (a) Chemical testing pursuant s. ATCP 76.14. (b) Backwashing completion. (c) Breakpoint chlorination. (d) Interlock testing. (e) Anti-entrapment system testing. (f) Water temperature. (g) Safety and rescue equipment maintaining pursuant to ss. ATCP 76.26 and ATCP 76.27. (h) If monthly reports are requested by t

      Code ATCP 76.32(1)

    • Not serious Action taken:

      32d - CARBON MONOXIDE ALARMS (P) - Not Corrected

      There is no carbon monoxide alarm in pool equipment room where there is a fuel burning appliance.

      Correction: Install functioning carbon monoxide alarms as applicable.

      Code ATCP 76.33(4)(d)

    • Not serious Other

      41a - MISCELLANEOUS - Not Corrected

      There is a 5 inch gap between fence and building near the splash pad area.

      Correction: Fences serving as barriers shall have no opening greater than 4 inches in width or diameter.

      Code SPS 390.18(4)

  3. Jun 25, 2026 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P)

      Operator cannot demonstrate knowledge or provide documentation of interlock system per requirements in ATCP 76.13(1)(c).

      Correction: Operator must be able to demonstrate knowledge and provide documentation of interlock system. Interlock must be tested at least once a month, with date, results and initials of tester.

      Code ATCP 76.13(1)(c)

    • Not serious Action taken:

      14a - CHLORINE TOO LOW (P)

      The chlorine residual was 0.2 at the time of the inspection.

      Correction: Close the pool and raise the chlorine residual to 1-10 ppm. Call inspector to schedule a reopening inspection.

      Code ATCP 76.14(4)(a)

    • Not serious Action taken:

      14e - WATER POTENTIAL ORP (Pf)

      The water potential was 331 mV at the time of the inspection. Operator states citric acid was added yesterday to address staining issues, which might be affecting ORP functionality.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.

      Code ATCP 76.14(5)(a)

    • Not serious Action taken:

      16d - COMBINED CHLORINE (Pf)

      The operator does not have a combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken:

      20e - WATER TESTING FREQUENCY - WITH ELECTRONIC MONITORING DEVICE (Pf)

      The water testing frequency for pH, combined chlorine, cyanuric acid, and alkalinity is not in compliance with ATCP 76.18(3).

      Correction: Perform water testing in accordance with ATCP 76.18(3). Test pH once a day, combined chlorine twice a week, cyanuric acid once a week, and alkalinity once a week.

      Code ATCP 76.18(3)

    • Not serious Action taken:

      21b - BACKFLOW - HOSE BIBBS (P)

      The hose bibb by the acid storage room and in the women's locker room is not protected against backsiphonage.

      Correction: Install a hose bibb atmospheric vacuum breaker that meets the ASSE 1011 standard on the hose bibb.

      Code ATCP 76.33(1)(d)

    • Not serious Action taken:

      21d - READABLE CHART

      There is no readable chart that describes the piping, valves, and direction of water flow.

      Correction: Labels, tags, or color coding shall correspond to a conspicuously posted, easily read chart that explains the system.

      Code ATCP 76.11(5m)(b)

    • Not serious Action taken:

      26h - RESCUE EQUIPMENT - ACCESSIBLE, GOOD REPAIR, SIZED (P)

      Ring buoy rope is not correctly connected to the buoy itself; rope is on a carabiner. Buoy is not required as guards always have rescue tubes.

      Correction: Connect rope directly to buoy or remove buoy from pool area.

      Code ATCP 76.26(1)

    • Not serious Action taken:

      26p - EMERGENCY NUMBERS AND ADDRESS (Pf)

      The emergency numbers are not posted near the designated emergency phone.

      Correction: Post the emergency and non-emergency numbers near the designated emergency phone.

      Code ATCP 76.26(2)(d)

    • Not serious Action taken:

      26r - FIRST AID KIT - SUPPLIES MISSING (Pf)

      Elastic bandage and non-expired eye wash are missing from the first aid kit.

      Correction: Provide all the items listed in ATCP 76.27(1)(b) in the first aid kit. 1. Gauze pads. 2. Adhesive bandages. 3. Gauze roller bandage. 4. Adhesive tape. 5. Eye wash. 6. Elastic bandage. 7. Disposable surgical gloves. 8. Resuscitation pocket face mask. 9. Instant cold packs.

      Code ATCP 76.27(1)(b)

    • Not serious Action taken: Wipes ordered per operator

      26t - BIOHAZARD SAFETY KIT (Pf)

      The biohazard safety kit is missing sanitizing hand wipes.

      Correction: Provide a biohazard safety kit with the items listed in ATCP 76.27(2)(b) at the first aid station or on the premise. 1. Scoop and spatula. 2. Sanitizing hand wipes. 3. Sanitizing surface wipes. 4. Neoprene gloves. 5. Paper toweling. 6. Biohazard disposal bag at least 24"X24". 7. Twist tie or other effective means to close the bag. 8. Biohazard sorbent. 9. Storage case.

      Code ATCP 76.27(2)

    • Not serious POOL SLIDES AND WATERSLIDES. For the plu

      27h - SIGNAGE - SLIDE RULES

      The letters for the pool slide rules are not at least 1 inch in height, and the water depth number is worn away.

      Correction: Provide an approved sign.

      Code ATCP 76.29(2)

    • Not serious Action taken:

      28e -REPORTS AND RECORDS (Pf)

      Operator is not using department-provided daily testing form.

      Correction: Use department-provided daily form and keep the following records available for review. (a) Chemical testing pursuant s. ATCP 76.14. (b) Backwashing completion. (c) Breakpoint chlorination. (d) Interlock testing. (e) Anti-entrapment system testing. (f) Water temperature. (g) Safety and rescue equipment maintaining pursuant to ss. ATCP 76.26 and ATCP 76.27. (h) If monthly reports are requested by t

      Code ATCP 76.32(1)

    • Not serious Action taken:

      32d - CARBON MONOXIDE ALARMS (P)

      There is no carbon monoxide alarm in pool equipment room where there is a fuel burning appliance.

      Correction: Install functioning carbon monoxide alarms as applicable.

      Code ATCP 76.33(4)(d)

    • Not serious Other

      41a - MISCELLANEOUS

      There is a 5 inch gap between fence and building near the splash pad area.

      Correction: Fences serving as barriers shall have no opening greater than 4 inches in width or diameter.

      Code SPS 390.18(4)

  4. Jun 26, 2025 Re-Inspection · No Reinspection Required
    • Not serious Action taken: Wipes ordered per operator

      26t - BIOHAZARD SAFETY KIT (Pf) - Not Corrected

      The biohazard safety kit is missing sanitizing hand wipes.

      Correction: Provide a biohazard safety kit with the items listed in ATCP 76.27(2)(b) at the first aid station or on the premise. 1. Scoop and spatula. 2. Sanitizing hand wipes. 3. Sanitizing surface wipes. 4. Neoprene gloves. 5. Paper toweling. 6. Biohazard disposal bag at least 24"X24". 7. Twist tie or other effective means to close the bag. 8. Biohazard sorbent. 9. Storage case.

      Code ATCP 76.27(2)

  5. Jun 17, 2025 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      11b - CHEMICAL - STORAGE (P)(Pf)

      Chemicals storage room doors are not marked to indicate entry is for authorized personnel only and a list of emergency telephone numbers is not in the room.

      Correction: Mark doors to chemical storage areas to indicate entry is for authorized personnel only and keep doors locked. Provide a list of emergency telephone numbers in the chemical storage room, or have numbers readily available.

      Code ATCP 76.12(2)

    • Not serious Action taken:

      16d - COMBINED CHLORINE (Pf)

      The operator does not have a combined chlorine action plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken: Email copies of all curren

      25e - LIFEGUARD - CERTIFICATIONS AVAILABLE (P)

      Copies of current lifeguard certifications for all guards are not available on site. Coordinator who has the certifications is out of state for a conference at time of inspection. Some lifeguards on duty just did Red Cross lifeguard certification this spring.

      Correction: Any lifeguards last certified more than 2 years ago relieved from duty. If the minimum lifeguard requirements in the approved staffing plan are not met as a result, the guarded pool or portion must be closed.

      Code ATCP 76.22(2)(a)

    • Not serious Action taken: Guards without current CPR

      25f - LIFEGUARD - CERTIFICATIONS MAINTAINED (P)

      Multiple lifeguards have CPR/AED certification that expired more than 1 year ago.

      Correction: The lifeguard must be relieved of duties until a current CPR/AED certification can be verified. If the minimum lifeguard requirements in the approved staffing plan are not met as a result, the guarded pool or portion must be closed.

      Code ATCP 76.22(2)(a)

    • Not serious Action taken:

      26g - BREATH HOLDING PROHIBITION - SIGNAGE

      Breath holding prohibition is not posted or communicated to patrons.

      Correction: Provide signage or otherwise communicate to patrons that activities involving prolonged breath holding are prohibited.

      Code ATCP 76.29(1)(f)

    • Not serious Action taken:

      26r - FIRST AID KIT - SUPPLIES MISSING (Pf)

      Tape, gauze pads, and eye was are missing from the first aid kit.

      Correction: Provide all the items listed in ATCP 76.27(1)(b) in the first aid kit. 1. Gauze pads. 2. Adhesive bandages. 3. Gauze roller bandage. 4. Adhesive tape. 5. Eye wash. 6. Elastic bandage. 7. Disposable surgical gloves. 8. Resuscitation pocket face mask. 9. Instant cold packs.

      Code ATCP 76.27(1)(b)

    • Not serious Action taken:

      26t - BIOHAZARD SAFETY KIT (Pf)

      The biohazard safety kit is missing sanitizing hand wipes.

      Correction: Provide a biohazard safety kit with the items listed in ATCP 76.27(2)(b) at the first aid station or on the premise. 1. Scoop and spatula. 2. Sanitizing hand wipes. 3. Sanitizing surface wipes. 4. Neoprene gloves. 5. Paper toweling. 6. Biohazard disposal bag at least 24"X24". 7. Twist tie or other effective means to close the bag. 8. Biohazard sorbent. 9. Storage case.

      Code ATCP 76.27(2)

    • Not serious Action taken: Alarm installed. Corrected on site

      32d - CARBON MONOXIDE ALARMS (P)

      There is no carbon monoxide alarm in pool equipment room where there is a fuel burning appliance.

      Correction: Install functioning carbon monoxide alarms as applicable.

      Code ATCP 76.33(4)(d)

    • Not serious Other Corrected on site

      41a - MISCELLANEOUS

      Emergency telephone is a cordless phone.

      Correction: Provide a telephone capable of connecting with emergency services that is a corded, connected phone. Cordless or cell phones are prohibited.

      Code ATCP 76.26(2)

  6. Jun 26, 2024 Re-Inspection · No Reinspection Required
    • Not serious Action taken:

      23b - NO CPO - Not Corrected

      The facility is not staffed with a current certified water attraction operator.

      Correction: Acquire or train a certified water attraction operator for the facility.

      Code ATCP 76.20(2)(a)

    • Not serious Action taken:

      24a - LIFEGUARD - STAFFING PLAN - Not Corrected

      The facility lifeguard staffing plan is out of date and missing diagrams for all uses of pool.

      Correction: Create a written plan pursuant to the requirements of ATCP 76.22 and submit it for approval.

      Code ATCP 76.22(1)(a)

    • Not serious Action taken: Template provided to opera

      28d - MONTHLY REPORTS AVAILABLE - Not Corrected

      Facility is not using department issued log sheet for recording of chemical tests.

      Correction: Keep records available for review and use department issued log sheet.

      Code ATCP 76.32(3)

    • Not serious Action taken: Operator plans to sandblas

      29b - BASIN DEFECTS - Not Corrected

      The pool basin is has multiple spots of pitting where the finish has eroded/chipped away.

      Correction: Repair the pool basin so it is finished and easily cleanable.

      Code ATCP 76.33(1)(a)

    • Not serious Action taken: Repair in progress.

      31b - EQUIPMENT NOT MAINTAINED - Not Corrected

      One of the sand filters is leaking from the side.

      Correction: Repair and maintain all equipment.

      Code ATCP 76.33(1)(e)

  7. Jun 17, 2024 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      11a - CHEMICAL - LABELING

      Large chemical tank is not labeled according to ATCP 76.12(1).

      Correction: Label the chemical container according to ATCP 76.12(1). Containers shall be conspicuously labeled with the following information: (a) Name of the product. (b) The manufacturer’s name and address. (c) Active ingredients. (d) Directions for use. (e) Hazardous ingredient warning. (f) The U.S. environmental protection agency registration number.

      Code ATCP 76.12(1)

    • Not serious Action taken:

      16c - ALKALINITY

      The total alkalinity is 210 ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(4)(d)

    • Not serious Action taken:

      20b - TEST KIT REAGENT STORAGE

      Some of the test kit reagents are expired.

      Correction: Keep reagents in original containers and replace upon expiration.

      Code ATCP 76.17(2)

    • Not serious Action taken:

      21c - DIRECTION OF FLOW

      The water treatment system piping is not marked with a permanent label indicating direction of flow. (New pipes installed this season.)

      Correction: Mark the water treatment system piping to indicate direction of flow.

      Code ATCP 76.11(5m)

    • Not serious Action taken:

      23b - NO CPO

      The facility is not staffed with a current certified water attraction operator.

      Correction: Acquire or train a certified water attraction operator for the facility.

      Code ATCP 76.20(2)(a)

    • Not serious Action taken:

      24a - LIFEGUARD - STAFFING PLAN

      The facility lifeguard staffing plan is out of date and missing diagrams for all uses of pool.

      Correction: Create a written plan pursuant to the requirements of ATCP 76.22 and submit it for approval.

      Code ATCP 76.22(1)(a)

    • Not serious Action taken:

      27c - SIGNAGE - SMALL LETTERS

      The letters on the pool rules signage are less than 1-inch in height.

      Correction: Provide an approved sign with all letters in at least 1 inch in height.

      Code ATCP 76.29(1)(b)

    • Not serious Action taken: Template provided to opera

      28d - MONTHLY REPORTS AVAILABLE

      Facility is not using department issued log sheet for recording of chemical tests.

      Correction: Keep records available for review and use department issued log sheet.

      Code ATCP 76.32(3)

    • Not serious Action taken:

      29b - BASIN DEFECTS

      The pool basin is has multiple spots of pitting where the finish has eroded/chipped away.

      Correction: Repair the pool basin so it is finished and easily cleanable.

      Code ATCP 76.33(1)(a)

    • Not serious Action taken:

      31b - EQUIPMENT NOT MAINTAINED

      One of the sand filters is leaking from the side.

      Correction: Repair and maintain all equipment.

      Code ATCP 76.33(1)(e)

  8. Jul 27, 2021 Routine Inspection · No Reinspection Required

    No violations cited.

  9. Jul 31, 2019 Routine Inspection · Reinspection Required

    No violations cited.

  10. Jun 8, 2017 Routine Inspection · No Reinspection Required

    No violations cited.

  11. Jun 17, 2016 Routine Inspection · No Reinspection Required

    No violations cited.

  12. Jun 17, 2015 Routine Inspection · No Reinspection Required

    No violations cited.

  13. Jul 11, 2014 Reinspection · No Reinspection Required

    No violations cited.

  14. Jun 16, 2014 Routine Inspection · Reinspection Required

    No violations cited.

  15. Jun 10, 2013 Routine Inspection · No Reinspection Required

    No violations cited.

  16. Jul 6, 2012 Routine Inspection · No Reinspection Required

    No violations cited.

Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.