RecordWell Data

Pinnacle Health & Fitness

5973 EXECUTIVE DR, Fitchburg, WI 53719 · Dane County

11cited violations
0serious tier
6inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
LICSWD-2019-00436
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026130
2024100
2023280
2021100
2019100

Inspections

  1. Aug 20, 2026 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      24a - LIFEGUARD - STAFFING PLAN (Ppf)

      The facility does not have a lifeguard staffing plan for the occasional instructional program taught in the outdoor pool.

      Correction: Create a written plan pursuant to the requirements of ATCP 76.22 and submit it for approval.

      Code ATCP 76.22(1)

    • Not serious Action taken: Instructional programming

      25d - LIFEGUARD - APPROVED CERTIFICATION (P)

      All 7 certifications for lifeguards in binder were taken more than 1 year ago and no additional CPR/AED certification is available. Lifeguards are needed at pool for instructional programs.

      Correction: The lifeguard must be relieved of instructional program duties until the certification from an approved course can be verified.

      Code ATCP 76.22(2)(a)

    • Not serious Action taken: PIC attached rope to ring Corrected on site

      26h - RESCUE EQUIPMENT - ACCESSIBLE, GOOD REPAIR, SIZED (P)

      Ring buoy and rope is on site but not readily accessible as rope is detached from ring buoy.

      Correction: Mount in a consipicuous place that is readily accessible, and maintain in good repair.

      Code ATCP 76.26(1)

  2. Aug 8, 2024 Routine Inspection · No Reinspection Required

    No violations cited.

  3. Jul 19, 2023 Re-Inspection · No Reinspection Required
    • Not serious Action taken:

      04c - SKIMMER BASKET/WEIR - Not Corrected

      Weir doors are missing.

      Correction: Replace.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken: Discussed testing Cl and p

      20c - WATER TESTING - POOLS - Not Corrected

      The water testing frequency for pH, chlorine, and cyanuric acid is not in compliance with ATCP 76.18(1). pH and chlorine is usually tested once a day and there is not ORP set-up. Cyanuric acid is not tested consistently once per week.

      Correction: Perform water testing in accordance with ATCP 76.18(1).

      Code ATCP 76.18(1)

    • Not serious Action taken:

      31b - EQUIPMENT NOT MAINTAINED - Not Corrected

      Railings on the edge of the staircase are not tightly secure and wiggle.

      Correction: Repair and maintain all equipment.

      Code ATCP 76.33(1)

  4. Jul 19, 2023 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      04c - SKIMMER BASKET/WEIR

      Weir doors are missing.

      Correction: Replace.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken: Discussed testing Cl and p

      20c - WATER TESTING - POOLS

      The water testing frequency for pH, chlorine, and cyanuric acid is not in compliance with ATCP 76.18(1). pH and chlorine is usually tested once a day and there is not ORP set-up. Cyanuric acid is not tested consistently once per week.

      Correction: Perform water testing in accordance with ATCP 76.18(1).

      Code ATCP 76.18(1)

    • Not serious Action taken: The PIC worked on the phon

      26m - TELEPHONE - NOT WORKING

      The pool phone calls direct to 911 and the red indicator light blinks and then stays solid during the call. The emergency telephone connects to dispatch, but there is no dial tone or audio heard poolside. To follow-up on the call, dispatch contacted the main office of the establishment and informed that 911 can hear the call and caller on their end. Communication is one-way.

      Correction: Provide a functional emergency telephone immediately.

      Code ATCP 76.26(2)

    • Not serious Action taken:

      31b - EQUIPMENT NOT MAINTAINED

      Railings on the edge of the staircase are not tightly secure and wiggle.

      Correction: Repair and maintain all equipment.

      Code ATCP 76.33(1)

    • Not serious Other

      34e - VGBA COVERS

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date. Pool opened in 2019, records are available for the other basins.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  5. Jul 21, 2021 Routine Inspection · No Reinspection Required

    No violations cited.

  6. Jul 23, 2019 Pre-Inspection · No Reinspection Required

    No violations cited.

Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.