Province Hill Apartments
7602 MID TOWN RD, Madison, WI 53719 · Dane County
Establishment
- Type
- Pool / recreational water (Swimming Pool)
- Inspected by
- Public Health Madison & Dane County
- License / ID
- 61488-58699
- Official record
- Public Health Madison & Dane County inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 0 | 0 |
| 2025 | 1 | 0 | 0 |
| 2023 | 2 | 6 | 0 |
| 2022 | 2 | 8 | 0 |
| 2021 | 1 | 0 | 0 |
| 2019 | 2 | 0 | 0 |
| 2018 | 1 | 0 | 0 |
| 2017 | 1 | 0 | 0 |
| 2016 | 1 | 0 | 0 |
| 2015 | 2 | 0 | 0 |
| 2014 | 1 | 0 | 0 |
| 2013 | 1 | 0 | 0 |
| 2012 | 1 | 0 | 0 |
Inspections
-
Jun 23, 2026 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 11, 2025 Routine Inspection · No Reinspection Required
No violations cited.
-
Aug 11, 2023 Re-Inspection · No Reinspection Required
-
Not serious
Action taken:
16c - ALKALINITY - Not Corrected
The total alkalinity is 40ppm.
Correction: Maintain the total alkalinity between 60 and 180 ppm.
Code ATCP 76.14(4)(d)
-
Not serious
Other
34e - VGBA COVERS - Not Corrected
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date. Equalizer covers expired July 2017.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
-
Aug 10, 2023 Routine Inspection · Reinspection Required
-
Not serious
Action taken:
14e - WATER POTENTIAL ORP
The water potential was 580mV at the time of the inspection.
Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.
Code ATCP 76.14(5)(a)
-
Not serious
Action taken:
16b - CYANURIC ACID
The cyanuric acid concentration is 50ppm.
Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.
Code ATCP 76.14(4)(b)
-
Not serious
Action taken: Gate Locked, no entry from
34c - DOOR/GATE
The door or gate to the pool enclosure is not self-closing, self-latching, and/or is not lockable.
Correction: Repair the door immediately so that it is self-closing, self-latching, and is lockable.
Code ATCP 76.34(4)
-
Not serious
Other
34e - VGBA COVERS
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date. Equalizer covers expired July 2017.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
-
Aug 3, 2022 Re-Inspection · No Reinspection Required
-
Not serious
Action taken:
16c - ALKALINITY - Not Corrected
The total alkalinity is 40ppm.
Correction: Maintain the total alkalinity between 60 and 180 ppm.
Code ATCP 76.14(4)(d)
-
Not serious
Action taken: Gate locked.
34c - DOOR/GATE - Not Corrected
The door or gate to the pool enclosure is not self-closing, self-latching, and/or is not lockable.
Correction: Repair the door immediately so that it is self-closing, self-latching, and is lockable. Gate may remain permanently locked until proper hardware installed meeting fire and pool codes.
Code ATCP 76.34(4)
-
Not serious
Other
34e - VGBA COVERS - Not Corrected
Equilizer covers expired July 2017.
Correction: Replace covers and maintain documentation of replacement date, make and model.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
-
Aug 2, 2022 Routine Inspection · Reinspection Required
-
Not serious
Action taken: Pool Closed
14a - CHLORINE TOO LOW
The chlorine residual was 1.0ppm at the time of the inspection.
Correction: Close the pool and raise the chlorine residual to at least 1.5ppm and not greater than 10ppm. Call inspector to schedule a reopening inspection.
Code ATCP 76.14(4)(a)
-
Not serious
Action taken:
16c - ALKALINITY
The total alkalinity is 40ppm.
Correction: Maintain the total alkalinity between 60 and 180 ppm.
Code ATCP 76.14(4)(d)
-
Not serious
Action taken:
20e - WATER TESTING FREQUENCY - ORP
The water testing frequency for pH and chlorine residue is not in compliance with ATCP 76.18(3).
Correction: Test pH and chlorine residue 2/day until ORP is properly functioning and reads between 650-850mV.
Code ATCP 76.18(3)
-
Not serious
Action taken: Gate locked.
34c - DOOR/GATE
The door or gate to the pool enclosure is not self-closing, self-latching, and/or is not lockable.
Correction: Repair the door immediately so that it is self-closing, self-latching, and is lockable. Gate may remain permanently locked until proper hardware installed meeting fire and pool codes.
Code ATCP 76.34(4)
-
Not serious
Other
34e - VGBA COVERS
Equilizer covers expired July 2017.
Correction: Replace covers and maintain documentation of replacement date, make and model.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken: Pool Closed
-
Jul 9, 2021 Routine Inspection · No Reinspection Required
No violations cited.
-
Jul 31, 2019 Re-Inspection · No Reinspection Required
No violations cited.
-
Jul 30, 2019 Routine Inspection · Reinspection Required
No violations cited.
-
Jul 6, 2018 Routine Inspection · No Reinspection Required
No violations cited.
-
Jul 13, 2017 Routine Inspection · No Reinspection Required
No violations cited.
-
Jul 26, 2016 Routine Inspection · No Reinspection Required
No violations cited.
-
Aug 20, 2015 Routine Inspection · No Reinspection Required
No violations cited.
-
Jul 8, 2015 Routine Inspection · No Reinspection Required
No violations cited.
-
Jul 31, 2014 Routine Inspection · No Reinspection Required
No violations cited.
-
Jul 30, 2013 Routine Inspection · No Reinspection Required
No violations cited.
-
Jul 19, 2012 Routine Inspection · No Reinspection Required
No violations cited.
Source: Public Health Madison & Dane County. History last read Oct 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.