Richard's House
1625 Capital AVE, Madison, WI 53705 · Dane County
Establishment
- Type
- Lodging (Hotel/Motel)
- Inspected by
- Public Health Madison & Dane County
- License / ID
- LICHMD-2018-00001
- Official record
- Public Health Madison & Dane County inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2025 | 1 | 4 | 0 |
| 2022 | 1 | 0 | 0 |
| 2021 | 1 | 1 | 0 |
| 2019 | 2 | 0 | 0 |
| 2018 | 1 | 0 | 0 |
Inspections
-
Jun 3, 2025 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
46a - SMOKE DETECTORS
Smoke detector does not have a date of manufacture or UL certification.
Correction: Provide operational smoke detectors in all sleeping rooms and required locations. Smoke detector shall be within 10 years of the date of manufacture and meet UL 217 certification.
Code ATCP 72.14(2)(c)
-
Not serious
Other
46b - CO DETECTOR PLACEMENT
Carbon monoxide detector not located in the immediate vicinity of the sleeping rooms on the main floor. Carbon monoxide detectors on main floor and 2nd floor have a manufacture date of 2014.
Correction: Provide operational carbon monoxide detectors in the sleeping areas in the immediate vicinity of the sleeping rooms. Carbon monoxide detectors shall be within 10 years of the date of manufacture and meet UL 2034 certification.
Code ATCP 72.145(3)
-
Not serious
Action taken:
47a - DOOR LOCKS
Door lock on main floor front porch sleeping room door is key-locking from the inside.
Correction: Provide door locks for key locking from the outside and non-key locking from the inside OR remove the door lock if renting the entire tourist rooming house to only one rental party at a time.
Code ATCP 72.14(2)(d)
-
Not serious
Other
56a - MISCELLANEOUS
1) A handrail is not provided on staircase leading to front door . 2) A section of the guard rail along the main floor elevated surface adjacent to the front porch sleeping room is 34-35 inches high. A smaller section closer to the house is 29.5 inches high.. There is a 12.5 inch gap between this elevated surface and the 1st metal bar on the section of guard that attaches to the house. 3)The guard along the 2nd floor hallway is 32 inches high.
Correction: 1) Provide a handrail that is 30-38 inches high, measured from the nosing of the stair tread or obtain an approved variance. 2) Provide guards that are at least 36 inches high on main floor elevated surface adjacent to porch sleeping room or obtain an approved variance. Gaps shall be 6 inches or less. 3) Provide guard along 2nd floor hallway that is at least 36 inches high or obtain an approved va
Code ATCP 72.14(1)
-
Not serious
Action taken:
-
Nov 16, 2022 Routine Inspection · No Reinspection Required
No violations cited.
-
Nov 29, 2021 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
53a - PREMISE MAINTAINED
Premise is not maintained free from hazard: ground level deck railings are loose.
Correction: Maintain premise in a clean condition, free from refuse and hazards. Provide stable railings for all decks.
Code ATCP 72.15(4)
-
Not serious
Action taken:
-
Dec 12, 2019 Routine Inspection · No Reinspection Required
No violations cited.
-
Feb 13, 2019 Routine Inspection · No Reinspection Required
No violations cited.
-
Jan 26, 2018 Pre-Inspection · No Reinspection Required
No violations cited.
Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.