RecordWell Data

Shivam Hospitality LLC

660 NYGAARD ST, Stoughton, WI 53589 · Dane County

41cited violations
0serious tier
17inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
LICSWD-2011-00028
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026260
20242200
2023140
20222110
2019200
2018200
2017100
2016100
2015100
2014100
2013100
2012100

Inspections

  1. Jun 10, 2026 Re-Inspection · No Reinspection Required
    • Not serious Action taken: Repeat

      09a - FLOW METER (P - Not Corrected

      The flow meter is not functional.

      Correction: Repair, replace, or install the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken:

      24b - LIFEGUARD - SIGNAGE MISSING (Ppf) - Not Corrected

      Facility does not have a 'Warning: No Lifeguard on Duty' that has 4 inch lettering.

      Correction: Provide a 'Warning: No Lifeguard on Duty Sign' with 4 inch letters.

      Code ATCP 76.23(2)

    • Not serious Action taken: Door was locked. Service t

      34d - DOOR/GATE (P) - Not Corrected

      The door closest to the pool is not latching.

      Correction: Repair the door immediately so that it is self-closing, latching, lockable, and does not require a key, punch code, or electronic method to exit the pool enclosure.

      Code ATCP 76.34(4)

  2. Jun 4, 2026 Routine Inspection · Reinspection Required
    • Not serious Action taken: Repeat

      09a - FLOW METER (P

      The flow meter is not functional.

      Correction: Repair, replace, or install the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken:

      24b - LIFEGUARD - SIGNAGE MISSING (Ppf)

      Facility does not have a 'Warning: No Lifeguard on Duty' that has 4 inch lettering.

      Correction: Provide a 'Warning: No Lifeguard on Duty Sign' with 4 inch letters.

      Code ATCP 76.23(2)

    • Not serious Action taken: Door was locked. Service t

      34d - DOOR/GATE (P)

      The door closest to the pool is not latching.

      Correction: Repair the door immediately so that it is self-closing, latching, lockable, and does not require a key, punch code, or electronic method to exit the pool enclosure.

      Code ATCP 76.34(4)

  3. Mar 27, 2024 Re-Inspection · No Reinspection Required
    • Not serious Action taken:

      11e - SDS AVAILABILITY - Not Corrected

      Safety data sheets are not available for all chemicals used in the facility.

      Correction: Provide safety data sheets for all chemicals used in the facility.

      Code ATCP 76.12(4)(b)

    • Not serious Action taken:

      21b - BACKFLOW - HOSE BIBBS - Not Corrected

      The hose bibb in the pump room by the water fill pipes is not protected against backsiphonage.

      Correction: Install a hose bibb atmospheric vacuum breaker that meets the ASSE 1011 standard on the hose bibb.

      Code ATCP 76.33(1)(d)

    • Not serious Action taken: On order per operator.

      24b - LIFEGUARD - SIGNAGE MISSING - Not Corrected

      The 'No Lifeguard on Duty' sign has letters less than 4 inches.

      Correction: Provide a 'No Lifeguard on Duty Sign' with 4 inch letters.

      Code ATCP 76.22(1)(c); ATCP 76.23(2)

    • Not serious Action taken: On order per operator.

      26o - EMERGENCY NUMBERS AND ADDRESS - Not Corrected

      The emergency numbers and/or the facility's location are not posted near the designated emergency phone.

      Correction: Post the emergency numbers near the designated emergency phone.

      Code ATCP 76.26(2)

    • Not serious Action taken: on order per operator

      27d - SIGNAGE - NO DIVING - Not Corrected

      The 'NO DIVING' has letters less than 4 inches in height.

      Correction: Post approved signage with letters at least 4 inches in height.

      Code ATCP 76.29(1)(c)

  4. Mar 19, 2024 Routine Inspection · Reinspection Required
    • Not serious Action taken: Repeat

      09a - FLOW METER

      The flow meter for the pool is not functional.

      Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken: Door closed and locked by Corrected on site

      11b - CHEMICAL - STORAGE

      Door to chemical area was propped open.

      Correction: Doors to chemical storage areas shall be locked.

      Code ATCP 76.12(2)(i)

    • Not serious Action taken:

      11e - SDS AVAILABILITY

      Safety data sheets are not available for all chemicals used in the facility.

      Correction: Provide safety data sheets for all chemicals used in the facility.

      Code ATCP 76.12(4)(b)

    • Not serious Action taken:

      20b - TEST KIT REAGENT STORAGE

      Test kit reagents R-0003 and R-0870 (DPD powder) are expired.

      Correction: Replace reagents.

      Code ATCP 76.17(2)

    • Not serious Action taken:

      20c - WATER TESTING - POOLS

      The water testing frequency for pH and free chlorine is not in compliance with ATCP 76.18(1). Tests are only recorded once per day.

      Correction: Perform water testing in accordance with ATCP 76.18(1).

      Code ATCP 76.18(1)

    • Not serious Action taken:

      21b - BACKFLOW - HOSE BIBBS

      The hose bibb in the pump room by the water fill pipes is not protected against backsiphonage.

      Correction: Install a hose bibb atmospheric vacuum breaker that meets the ASSE 1011 standard on the hose bibb.

      Code ATCP 76.33(1)(d)

    • Not serious Action taken:

      24b - LIFEGUARD - SIGNAGE MISSING

      The 'No Lifeguard on Duty' sign has letters less than 4 inches.

      Correction: Provide a 'No Lifeguard on Duty Sign' with 4 inch letters.

      Code ATCP 76.22(1)(c); ATCP 76.23(2)

    • Not serious Action taken: Phone was repaired by oper Corrected on site

      26m - TELEPHONE - NOT WORKING

      The emergency telephone does not work.

      Correction: Provide a functional emergency telephone immediately.

      Code ATCP 76.26(2)

    • Not serious Action taken:

      26o - EMERGENCY NUMBERS AND ADDRESS

      The emergency numbers and/or the facility's location are not posted near the designated emergency phone.

      Correction: Post the emergency numbers near the designated emergency phone.

      Code ATCP 76.26(2)

    • Not serious Action taken: The first aid kit shall co

      26q - FIRST AID KIT - SUPPLIES MISSING

      Multiple items are missing from the first aid kit.

      Correction: Provide all the items listed in ATCP 76.27(1) in the first aid kit.

      Code ATCP 76.27(1)

    • Not serious Action taken:

      26r - BLANKETS MISSING

      2 durable blankets are not available in the pool area.

      Correction: Provide 2 durable blankets in the pool area.

      Code ATCP 76.27(1)

    • Not serious Action taken: A biohazard kit shall cont

      26s - BIOHAZARD SAFETY KIT

      No biohazard safety kit is located on the premises.

      Correction: Provide a biohazard safety kit at the first aid station.

      Code ATCP 76.27(2)

    • Not serious Action taken:

      27d - SIGNAGE - NO DIVING

      The 'NO DIVING' has letters less than 4 inches in height.

      Correction: Post approved signage with letters at least 4 inches in height.

      Code ATCP 76.29(1)(c)

    • Not serious Action taken: Service technician repaire Corrected on site

      34c - DOOR/GATE

      The western exit door in the pool room is not lockable. All exit doors were at one point propped open during the inspection.

      Correction: Repair the door immediately so that it is self-closing, self-latching, and is lockable.

      Code ATCP 76.34(4)

    • Not serious Other

      34e - VGBA COVERS

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  5. Mar 29, 2023 Routine Inspection · No Reinspection Required
    • Not serious Action taken: Repeat

      09a - FLOW METER

      The flow meter is not functional, the bobber is stuck.

      Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken: Sanitarian to send new tes

      20c - WATER TESTING - POOLS

      The water testing frequency is not in compliance with ATCP 76.18(1).

      Correction: Perform water testing in accordance with ATCP 76.18(1).

      Code ATCP 76.18(1)

    • Not serious Action taken: Sanitarian to send list of

      26q - FIRST AID KIT - SUPPLIES MISSING

      Items are missing from the first aid kit or are expired (eye wash).

      Correction: Provide all the items listed in ATCP 76.27(1) in the first aid kit.

      Code ATCP 76.27(1)

    • Not serious Action taken:

      29b - BASIN DEFECTS

      The pool basin is has patches where the the paint appears to be peeling.

      Correction: Repair the pool basin so it is finished and easily cleanable.

      Code ATCP 76.33(1)(a)

  6. Mar 10, 2022 Re-Inspection · No Reinspection Required
    • Not serious Action taken:

      06a - SPARE STRAINER BASKET - Not Corrected

      A spare strainer basket or screen for the skimmers and the recirculation pump are not located on site.

      Correction: Provide a spare basket or screen.

      Code ATCP 76.11(2)(d)

    • Not serious Action taken:

      09a - FLOW METER - Not Corrected

      The flow meter bobber is stuck and not functional.

      Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken:

      24b - LIFEGUARD - SIGNAGE MISSING - Not Corrected

      Signage present, however the 'No Lifeguard on Duty' sign has letters less than 4 inches.

      Correction: Provide a 'No Lifeguard on Duty Sign' with 4 inch letters.

      Code ATCP 76.22(1)(c); ATCP 76.23(2)

    • Not serious Action taken:

      29f - DEPTH MARKINGS VISIBLE - Not Corrected

      The depth markings along the edge of the pool are fading.

      Correction: Repair the markings so they are clearly visible and readable.

      Code ATCP 76.33(1)(b)

    • Not serious Other

      34e - VGBA COVERS - Not Corrected

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  7. Mar 9, 2022 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      06a - SPARE STRAINER BASKET

      A spare strainer basket or screen for the skimmers and the recirculation pump are not located on site.

      Correction: Provide a spare basket or screen.

      Code ATCP 76.11(2)(d)

    • Not serious Action taken:

      09a - FLOW METER

      The flow meter bobber is stuck and not functional.

      Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken:

      24b - LIFEGUARD - SIGNAGE MISSING

      Signage present, however the 'No Lifeguard on Duty' sign has letters less than 4 inches.

      Correction: Provide a 'No Lifeguard on Duty Sign' with 4 inch letters.

      Code ATCP 76.22(1)(c); ATCP 76.23(2)

    • Not serious Action taken:

      29f - DEPTH MARKINGS VISIBLE

      The depth markings along the edge of the pool are fading.

      Correction: Repair the markings so they are clearly visible and readable.

      Code ATCP 76.33(1)(b)

    • Not serious Action taken: Pool closed. Maintenance p

      34c - DOOR/GATE

      The door that opens directly to the back of the building is not self-closing or self-latching, the self-closer is completely rusted. The door that leads to the parking lot/ front of building does not open.

      Correction: Repair the door immediately so that it is self-closing, self-latching, and is lockable.

      Code ATCP 76.34(4)

    • Not serious Other

      34e - VGBA COVERS

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  8. Dec 11, 2019 Re-Inspection · No Reinspection Required

    No violations cited.

  9. Dec 10, 2019 Routine Inspection · Reinspection Required

    No violations cited.

  10. May 9, 2018 Re-Inspection · Reinspection Required

    No violations cited.

  11. Apr 26, 2018 Routine Inspection · Reinspection Required

    No violations cited.

  12. May 24, 2017 Routine Inspection · No Reinspection Required

    No violations cited.

  13. Feb 2, 2016 Routine Inspection · No Reinspection Required

    No violations cited.

  14. Mar 5, 2015 Routine Inspection · No Reinspection Required

    No violations cited.

  15. Jan 29, 2014 Routine Inspection · No Reinspection Required

    No violations cited.

  16. Jan 7, 2013 Routine Inspection · No Reinspection Required

    No violations cited.

  17. Feb 6, 2012 Routine Inspection · No Reinspection Required

    No violations cited.

Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.