RecordWell Data

Stonefield Terrace

845 PEBBLE BEACH DR, Madison, WI 53717 · Dane County

14cited violations
0serious tier
13inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
40506-26319
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026100
2025290
2023150
2021100
2019100
2018100
2017100
2016100
2015100
2014100
2013100
2012100

Inspections

  1. Aug 26, 2026 Routine Inspection · No Reinspection Required

    No violations cited.

  2. Jul 23, 2025 Re-Inspection · No Reinspection Required
    • Not serious Action taken: Template provided with ema

      16d - COMBINED CHLORINE (Pf) - Not Corrected

      The operator does not have a combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken: Pump curve provided; other

      28f - FILES MAINTAINED - Not Corrected

      CDC fecal incident procedures, pump curve, and most current monthly reports are not permanently maintained on the premise.

      Correction: Provide all files pursuant to ATCP 76.32(3).

      Code ATCP 76.32(3)

  3. Jul 21, 2025 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      11b - CHEMICAL - STORAGE (P)(Pf)

      Doors to chemical storage area is not marked with authorized personnel only.

      Correction: Mark chemical storage area doors with authorized personnel only.

      Code ATCP 76.12(2)

    • Not serious Action taken: Template provided with ema

      16d - COMBINED CHLORINE (Pf)

      The operator does not have a combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken:

      21b - BACKFLOW - HOSE BIBBS (P)

      The hose bibb is not protected against backsiphonage.

      Correction: Install a hose bibb atmospheric vacuum breaker that meets the ASSE 1011 standard on the hose bibb.

      Code ATCP 76.33(1)(d)

    • Not serious Action taken:

      28f - FILES MAINTAINED

      CDC fecal incident procedures, pump curve, and most current monthly reports are not permanently maintained on the premise.

      Correction: Provide all files pursuant to ATCP 76.32(3).

      Code ATCP 76.32(3)

    • Not serious Action taken:

      32d - CARBON MONOXIDE ALARMS (P)

      There is no carbon monoxide alarm in pool equipment room and in the indoor pool area where there is a fuel burning appliance.

      Correction: Install functioning carbon monoxide alarms as applicable.

      Code ATCP 76.33(4)(d)

    • Not serious Action taken:

      34b - GATE LATCH AND LOCK MECHANISHM LOCATION (P)

      A self-closing and lockable mechanism is not properly installed on club house door. Door to pool locked and sign placed prohibiting use. Club house entry door will remain locked until mechanism installed and patron will use designated pool door to enter pool which is self-closing, latching and lockable.

      Correction: Install a self-closing latching and lockable mechanism on door.

      Code ATCP 76.34(2)(b)

    • Not serious Other

      41a - MISCELLANEOUS

      New variable speed pump, new diatomaceous earth filter, and new liquid chlorine system (previously trichlor tablet used) installed on or about May 2024 but no state plan approval letter on premise. Operator states engineering plans and approval letter with installer. Receipt shows fees paid for engineering plan and state approval letter. Main drain peak flow is rated at 147 GPM, and flow meter reads 70 GPM.

      Correction: Submit engineering plans and DSPS approval letter.

      Code 76.04

  4. Jul 27, 2023 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      04c - SKIMMER BASKET/WEIR

      Two weirs are missing.

      Correction: Replace.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken:

      14e - WATER POTENTIAL ORP

      The water potential was 429mV at the time of the inspection.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.

      Code ATCP 76.14(5)(a)

    • Not serious Action taken:

      16b - CYANURIC ACID

      The cyanuric acid concentration is 60ppm.

      Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.

      Code ATCP 76.14(4)(b)

    • Not serious Action taken:

      21b - BACKFLOW - HOSE BIBBS

      The hose bibb is not protected against backsiphonage.

      Correction: Install a hose bibb atmospheric vacuum breaker that meets the ASSE 1011 standard on the hose bibb.

      Code ATCP 76.33(1)(d)

    • Not serious Action taken:

      27d - SIGNAGE - NO DIVING

      'NO DIVING' is not posted in the pool rules.

      Correction: Post approved signage with letters at least 4 inches in height.

      Code ATCP 76.29(1)(c)

  5. Aug 17, 2021 Routine Inspection · No Reinspection Required

    No violations cited.

  6. Aug 21, 2019 Routine Inspection · No Reinspection Required

    No violations cited.

  7. Jun 4, 2018 Routine Inspection · No Reinspection Required

    No violations cited.

  8. Jun 7, 2017 Routine Inspection · No Reinspection Required

    No violations cited.

  9. Jun 9, 2016 Routine Inspection · No Reinspection Required

    No violations cited.

  10. May 28, 2015 Routine Inspection · No Reinspection Required

    No violations cited.

  11. Jun 3, 2014 Routine Inspection · No Reinspection Required

    No violations cited.

  12. Jun 11, 2013 Routine Inspection · No Reinspection Required

    No violations cited.

  13. Jun 18, 2012 Routine Inspection · No Reinspection Required

    No violations cited.

Source: Public Health Madison & Dane County. History last read Nov 3, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.