RecordWell Data

Swimwest Family Fitness Center

1001 DEMING WAY, Madison, WI 53717 · Dane County

51cited violations
0serious tier
14inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
47872-36586
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20262320
20242190
2023100
2022100
2019100
2018100
2017100
2016100
2015100
2014100
2013100
2012100

Inspections

  1. May 11, 2026 Re-Inspection · No Reinspection Required
    • Not serious Action taken:

      11e - SDS AVAILABILITY (Pf) - Not Corrected

      Safety data sheets are not available for all chemicals used in the facility. Staff is unfamiliar with the universal 16-section format, pictogram meaning, and guidance on personal protection found in safety data sheets.

      Correction: Provide safety data sheets for all chemicals used in the facility, including safety data sheets for test kit reagents. Provide safety data sheet training.

      Code ATCP 76.12(4)(b)

    • Not serious Action taken: Factsheet and video refere

      13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P) - Not Corrected

      Operator cannot demonstrate knowledge and/or provide documentation of interlock system per requirements in ATCP 76.13(1)(c).

      Correction: Operator must be able to demonstrate knowledge and provide documentation of interlock system.

      Code ATCP 76.13(1)(c)

    • Not serious Action taken: Combined chlorine plan pro

      16d - COMBINED CHLORINE (Pf) - Not Corrected

      The operator does not have a combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken:

      24a - LIFEGUARD - STAFFING PLAN (Ppf) - Not Corrected

      The facility does not have a lifeguard and/or attendant staffing plan. Required certifications for lifeguards verified and lifeguards present at all times for instructional classes and open swim as stated by operator.

      Correction: Create a written plan pursuant to the requirements of ATCP 76.22 and submit it for approval. Include diagrams for each use of the pool such as instructional program and open swim.

      Code ATCP 76.22(1)

    • Not serious Action taken: Sign provided with emailed

      26g - BREATH HOLDING PROHIBITION - SIGNAGE - Not Corrected

      Breath holding prohibition is not posted or communicated to patrons.

      Correction: Provide signage or otherwise communicate to patrons that activities involving prolonged breath holding are prohibited.

      Code ATCP 76.29(1)(f)

    • Not serious Action taken: Current month report form

      28e -REPORTS AND RECORDS (Pf) - Not Corrected

      Required recordkeeping is not complete or available for review.

      Correction: Keep the following records available for review. (a) Chemical testing pursuant s. ATCP 76.14. (b) Backwashing completion. (c) Breakpoint chlorination. (d) Interlock testing. (e) Anti-entrapment system testing. (f) Water temperature. (g) Safety and rescue equipment maintaining pursuant to ss. ATCP 76.26 and ATCP 76.27. (h) If monthly reports are requested by the department or its agent, they shall

      Code ATCP 76.32(1)

    • Not serious Action taken:

      29e - DECK OBSTRUCTED (Pf) - Not Corrected

      Deck is obstructed with portable equipment such as shelves, chairs, benches, and cabinets making lifeguard roaming, patron passage, or water extrication difficult. Passage width is less than 3 feet in places.

      Correction: Remove the obstruction.

      Code ATCP 76.33(1)(b)

    • Not serious Action taken:

      29g - DRINKING FOUNTAIN (P) - Not Corrected

      The drinking fountain is not functional or not clean.

      Correction: Repair/clean the drinking fountain.

      Code ATCP 76.33(1)(g)

    • Not serious Action taken:

      30b - SHOWERS - Not Corrected

      The showers in the changing rooms have been permanently turned off and made into changing stalls. The only showers available are on the deck which have no soap dispensers.

      Correction: Repair the showers in operable condition. To minimize the risk of Legionella, ensure all water systems are safe. Water aged over 3 weeks is potentially viable for Legionella growth. It is strongly advised to develop and implement a water management program per CDC. A toolkit can be found at https://www.cdc.gov/legionella/wmp/toolkit/index.html.

      Code ATCP 76.33(2)(b)

    • Not serious Action taken:

      30e - SOAP (Pf) - Not Corrected

      No soap dispensers are available at abandoned showers in changing rooms.

      Correction: Provide soap at all hand washing sinks and showers.

      Code ATCP 76.33(2)(e)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf) - Not Corrected

      VGBA main drain and equalizer covers are all expired. All covers appear secure and intact. Documentation onsite for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date is incomplete and has not been kept up to date.

      Correction: Replace VGBA main drain cover and all equalizer covers. Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers onsite and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date. Until VGBA covers have been replaced, op

      Code ATCP 76.38

  2. May 11, 2026 Routine Inspection · Reinspection Required
    • Not serious Action taken: Baskets cleaned during ins Corrected on site

      06b - STRAINER BASKET CLEANED

      Skimmer baskets are not clean. Hair, toys, and other debris in baskets.

      Correction: Clean strainer baskets and screens daily to prevent the accumulation of debris.

      Code ATCP 76.11(2)(d)

    • Not serious Action taken:

      10b - BACKWASH - SAND FILTER (Pf)

      The sand filter is not being backwashed in accordance with ATCP 76.11(6)(b). Differential pressure was 20psi during inspection. Manufacturer recommends bachwashing at 15psi.

      Correction: Backwash the sand filter in accordance with manufacturer's recommendations.

      Code ATCP 76.11(6)(b)

    • Not serious Action taken:

      11e - SDS AVAILABILITY (Pf)

      Safety data sheets are not available for all chemicals used in the facility. Staff is unfamiliar with the universal 16-section format, pictogram meaning, and guidance on personal protection found in safety data sheets.

      Correction: Provide safety data sheets for all chemicals used in the facility, including safety data sheets for test kit reagents. Provide safety data sheet training.

      Code ATCP 76.12(4)(b)

    • Not serious Action taken: Factsheet and video refere

      13d - INTERLOCK DEMONSTRATION OF KNOWLEDGE AND DOCUMENTS (P)

      Operator cannot demonstrate knowledge and/or provide documentation of interlock system per requirements in ATCP 76.13(1)(c).

      Correction: Operator must be able to demonstrate knowledge and provide documentation of interlock system.

      Code ATCP 76.13(1)(c)

    • Not serious Action taken: Combined chlorine plan pro

      16d - COMBINED CHLORINE (Pf)

      The operator does not have a combined chlorine plan.

      Correction: Provide a plan with all components required under ATCP 76.14(5)(e)

      Code ATCP 76.14(5)(e)

    • Not serious Action taken:

      20c - WATER TESTING - POOLS (Pf)

      The water testing frequency for alkalinity is not in compliance with ATCP 76.18(1).

      Correction: Perform water testing in accordance with ATCP 76.18(1). Test alkalinity at least once per week.

      Code ATCP 76.18(1)

    • Not serious Action taken:

      24a - LIFEGUARD - STAFFING PLAN (Ppf)

      The facility does not have a lifeguard and/or attendant staffing plan. Required certifications for lifeguards verified and lifeguards present at all times for instructional classes and open swim as stated by operator.

      Correction: Create a written plan pursuant to the requirements of ATCP 76.22 and submit it for approval. Include diagrams for each use of the pool such as instructional program and open swim.

      Code ATCP 76.22(1)

    • Not serious Action taken:

      26a - PATRON LOAD - POOLS (Pf)

      The posted maximum patron load exceeds the legal requirements. Posted maximum patron load is 169. Calculation estimated at 127.

      Correction: Calculate and post the maximum patron load in compliance with ATCP 76.25(2).

      Code ATCP 76.25(2)(a)

    • Not serious Action taken: Sign provided with emailed

      26g - BREATH HOLDING PROHIBITION - SIGNAGE

      Breath holding prohibition is not posted or communicated to patrons.

      Correction: Provide signage or otherwise communicate to patrons that activities involving prolonged breath holding are prohibited.

      Code ATCP 76.29(1)(f)

    • Not serious Action taken: Pool closed by cease to op

      26n - TELEPHONE - NOT WORKING (P)

      The emergency telephone does not work.

      Correction: Provide a functional emergency telephone immediately.

      Code ATCP 76.26(2)

    • Not serious Action taken: Form provided with emailed

      28d - D-I-I REPORTS NOT SUBMITTED (Pf)

      A death, illness, or injury report was not submitted for an incident that required assistance from emergency medical personnel by the end of the next working day.

      Correction: Complete a death, illness, or injury report on the discussed incident and submit to datcpdfrsrec@wisconsin.gov to comply with the requirement.

      Code ATCP 76.32(2)

    • Not serious Action taken: Current month report form

      28e -REPORTS AND RECORDS (Pf)

      Required recordkeeping is not complete or available for review.

      Correction: Keep the following records available for review. (a) Chemical testing pursuant s. ATCP 76.14. (b) Backwashing completion. (c) Breakpoint chlorination. (d) Interlock testing. (e) Anti-entrapment system testing. (f) Water temperature. (g) Safety and rescue equipment maintaining pursuant to ss. ATCP 76.26 and ATCP 76.27. (h) If monthly reports are requested by the department or its agent, they shall

      Code ATCP 76.32(1)

    • Not serious Action taken:

      29a - BASIN CLEANING

      Sediment and other debris observed in the deep end of the basin and on the main drain cover and is in need of cleaning.

      Correction: Keep the basin in a clean and sanitary condition pursuant to ATCP 76.33(1)(a).

      Code ATCP 76.33(1)(a)

    • Not serious Action taken:

      29d - DECK MAINTENANCE AND CLEANING (Pf)

      The pool areas are not being cleaned and disinfected weekly and quaternary ammonia is being used as a disinfectant.

      Correction: Clean and sanitize the deck at least weekly. Avoid the use of an ammonia-based disinfectant as it can contribute to increased chloramines in the pool water. Use diluted chlorine bleach solution.

      Code ATCP 76.33(1)(b)

    • Not serious Action taken:

      29e - DECK OBSTRUCTED (Pf)

      Deck is obstructed with portable equipment such as shelves, chairs, benches, and cabinets making lifeguard roaming, patron passage, or water extrication difficult. Passage width is less than 3 feet in places.

      Correction: Remove the obstruction.

      Code ATCP 76.33(1)(b)

    • Not serious Action taken:

      29g - DRINKING FOUNTAIN (P)

      The drinking fountain is not functional or not clean.

      Correction: Repair/clean the drinking fountain.

      Code ATCP 76.33(1)(g)

    • Not serious Action taken:

      30b - SHOWERS

      The showers in the changing rooms have been permanently turned off and made into changing stalls. The only showers available are on the deck which have no soap dispensers.

      Correction: Repair the showers in operable condition. To minimize the risk of Legionella, ensure all water systems are safe. Water aged over 3 weeks is potentially viable for Legionella growth. It is strongly advised to develop and implement a water management program per CDC. A toolkit can be found at https://www.cdc.gov/legionella/wmp/toolkit/index.html.

      Code ATCP 76.33(2)(b)

    • Not serious Action taken:

      30e - SOAP (Pf)

      No soap dispensers are available at abandoned showers in changing rooms.

      Correction: Provide soap at all hand washing sinks and showers.

      Code ATCP 76.33(2)(e)

    • Not serious Action taken:

      32d - CARBON MONOXIDE ALARMS (P)

      There is an equipment room with a fuel burning appliance located within the pool area. A carbon monoxide alarm in the indoor pool area is not installed.

      Correction: Install functioning carbon monoxide alarm in the indoor pool area.

      Code ATCP 76.33(4)(d)

    • Not serious Action taken: Lane lines will be removed

      33a - HAZARDOUS MATERIAL (P)

      Covers are missing from lane line attachment ends connecting lane line to pool basin. Sharp edges present a hazard to swimmers.

      Correction: Provide lane line attachment covers.

      Code ATCP 76.34(1)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf)

      VGBA main drain and equalizer covers are all expired. All covers appear secure and intact. Documentation onsite for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date is incomplete and has not been kept up to date.

      Correction: Replace VGBA main drain cover and all equalizer covers. Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers onsite and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date. Until VGBA covers have been replaced, op

      Code ATCP 76.38

  3. Feb 1, 2024 Re-Inspection · No Reinspection Required
    • Not serious Action taken: As of 2/1/2024, work order

      29a - FACILITY CLEANING - Not Corrected

      Concrete is eroding at floor and wall juncture.

      Correction: Repair cracks and defects and refinish as necessary to maintain facility in cleanable condition.

      Code ATCP 76.33(1)(a)

    • Not serious Action taken:

      30e - SOAP - Not Corrected

      Soap dispenser are not provided at on deck showers.

      Correction: Provide soap at all hand washing sinks and showers in permanently installed dispensing devices.

      Code ATCP 76.33(2)(e)

    • Not serious Action taken: As of 2/1/2024, shepherd's

      31b - EQUIPMENT NOT MAINTAINED - Not Corrected

      (1) Shepherd's crook head attachment is loose. (2) Pool stair hand rails below water line are discolored.

      Correction: Repair and maintain all equipment.

      Code ATCP 76.33(1)(e)

    • Not serious Action taken: As of 2/1/2024, operator h

      34a - GATES NOT MAINTAINED - Not Corrected

      Snow cover prevent emergency doors to fully open and effective egress. Doors do not self-close. Must be pulled shut.

      Correction: Remove snow and adjust door closer mechanism to self-close and self-latch.

      Code ATCP 76.34(2)

    • Not serious Other

      34e - VGBA COVERS - Not Corrected

      Equalizer covers are expired as of 11/19/2023. All covers are observed to be secure and intact.

      Correction: Replace covers when lifespan is up. Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection.

      Code ATCP 76.11(2)(b)

  4. Jan 18, 2024 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      04c - SKIMMER BASKET/WEIR

      All weirs are missing

      Correction: Replace.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken:

      06a - SPARE STRAINER BASKET

      A spare skimmer strainer basket is not located on site.

      Correction: Provide a spare skimmer basket.

      Code ATCP 76.11(2)(d)

    • Not serious Action taken:

      11b - CHEMICAL - STORAGE

      Chemical storage is unclean. Acid and chlorine, incompatible chemicals, are stored next to each other.

      Correction: Store chemicals clean, dry and well ventilated area. Store incompatible chemicals separately.

      Code ATCP 76.12(2)

    • Not serious Action taken:

      11e - SDS AVAILABILITY

      Safety data sheets are not available for all chemicals used in the facility.

      Correction: Provide safety data sheets for all chemicals used in the facility.

      Code ATCP 76.12(4)(b)

    • Not serious Action taken:

      20b - TEST KIT REAGENT STORAGE

      The test kit reagent containers and kit instructions are difficult to read.

      Correction: Maintain kit and reagents in good working order and replace as recommended by the manufacturer.

      Code ATCP 76.17(2)

    • Not serious Action taken:

      21b - BACKFLOW - HOSE BIBBS

      The hose bibb nearest break room is not protected against backsiphonage.

      Correction: Install a hose bibb atmospheric vacuum breaker that meets the ASSE 1011 standard on the hose bibb.

      Code ATCP 76.33(1)(d)

    • Not serious Action taken:

      24a - LIFEGUARD - STAFFING PLAN

      Lifeguard and attendant staffing plan is out of date. Diagram not updated with remodel and missing for each use of the pool.

      Correction: Create a written plan pursuant to the requirements of ATCP 76.22 and submit it for approval. The written lifeguard and attendant staffing plan shall include all of the following: 1. The square footage of the pool. 2. The maximum and average patron load. 3. The hours of operation. 4. The location of each lifeguard station, lifeguard roaming or walking patrol ensuring that glare conditions are asses

      Code ATCP 76.22(1)(a-b)

    • Not serious Action taken:

      29a - FACILITY CLEANING

      Concrete is eroding at floor and wall juncture.

      Correction: Repair cracks and defects and refinish as necessary to maintain facility in cleanable condition.

      Code ATCP 76.33(1)(a)

    • Not serious Action taken:

      29e - DECK OBSTRUCTED

      The deck is obstructed with portable platforms making lifeguard roaming, patron passage or water extrication difficult. Passage way less than 3 feet.

      Correction: Remove the obstruction.

      Code ATCP 76.33(1)(b)

    • Not serious Action taken:

      30e - SOAP

      Soap dispenser are not provided at on deck showers.

      Correction: Provide soap at all hand washing sinks and showers in permanently installed dispensing devices.

      Code ATCP 76.33(2)(e)

    • Not serious Action taken:

      31b - EQUIPMENT NOT MAINTAINED

      (1) Shepherd's crook head attachment is loose. (2) Pool stair hand rails below water line are discolored.

      Correction: Repair and maintain all equipment.

      Code ATCP 76.33(1)(e)

    • Not serious Action taken:

      33a - HAZARDOUS MATERIAL

      Cover missing from lane line attachment end connecting lane line to pool basin. Sharp edges present hazard to swimmers.

      Correction: Provide lane line attachment cover.

      Code ATCP 76.34(1)

    • Not serious Action taken:

      34a - GATES NOT MAINTAINED

      Snow cover prevent emergency doors to fully open and effective egress. Doors do not self-close. Must be pulled shut.

      Correction: Remove snow and adjust door closer mechanism to self-close and self-latch.

      Code ATCP 76.34(2)

    • Not serious Other

      34e - VGBA COVERS

      Equalizer covers are expired as of 11/19/2023. All covers are observed to be secure and intact.

      Correction: Replace covers when lifespan is up. Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection.

      Code ATCP 76.11(2)(b)

  5. Mar 31, 2023 Routine Inspection · No Reinspection Required

    No violations cited.

  6. Feb 11, 2022 Routine Inspection · No Reinspection Required

    No violations cited.

  7. Nov 14, 2019 Routine Inspection · No Reinspection Required

    No violations cited.

  8. Jun 18, 2018 Routine Inspection · No Reinspection Required

    No violations cited.

  9. Jun 8, 2017 Routine Inspection · No Reinspection Required

    No violations cited.

  10. Apr 25, 2016 Routine Inspection · No Reinspection Required

    No violations cited.

  11. May 21, 2015 Routine Inspection · No Reinspection Required

    No violations cited.

  12. Jan 21, 2014 Routine Inspection · No Reinspection Required

    No violations cited.

  13. Feb 4, 2013 Routine Inspection · No Reinspection Required

    No violations cited.

  14. Feb 13, 2012 Routine Inspection · No Reinspection Required

    No violations cited.

Source: Public Health Madison & Dane County. History last read Nov 3, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.