The Vue At Pinnacle Park
1300 POST RD, Fitchburg, WI 53713 · Dane County
Establishment
- Type
- Pool / recreational water (Swimming Pool)
- Inspected by
- Public Health Madison & Dane County
- License / ID
- LICSWD-2020-00162
- Official record
- Public Health Madison & Dane County inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 5 | 0 |
| 2025 | 1 | 4 | 0 |
| 2024 | 2 | 8 | 0 |
| 2023 | 2 | 18 | 0 |
| 2021 | 1 | 0 | 0 |
| 2020 | 2 | 0 | 0 |
Inspections
-
May 26, 2026 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
04c - SKIMMER BASKET/WEIR
Both skimmer weir doors are missing.
Correction: Replace.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
16c - ALKALINITY (Pf)
The total alkalinity is 200 ppm.
Correction: Maintain the total alkalinity between 60 and 180 ppm.
Code ATCP 76.14(5)(d)
-
Not serious
Action taken: Operator attached rope at
Corrected on site
26h - RESCUE EQUIPMENT - ACCESSIBLE, GOOD REPAIR, SIZED (P)
Ring buoy is on site, but rope is not attached.
Correction: Mount properly sized ring buoy, position in a consipicuous place that is readily accessible, and maintain in good repair with rope attached.
Code ATCP 76.26(1)
-
Not serious
Action taken:
30f - HAND DRYING DEVICES (Pf)
No hand drying devices are available at the hand washing sink in the restroom. Batteries in paper towel dispenser need to be replaced.
Correction: Provide individual towels in dispensers or hot air dryers at hand washing sinks.
Code ATCP 76.33(2)(f)
-
Not serious
Action taken: Operator to contact repair
31b - EQUIPMENT NOT LOCATED/INSTALLED/MAINTAINED/ REPAIRED
Pool recirculation pump has a slow leak.
Correction: Properly locate, intall, maintain and repair equipment.
Code ATCP 76.33(1)(e)
-
Not serious
Action taken:
-
Jun 4, 2025 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
04c - SKIMMER BASKET/WEIR
Both skimmer weir doors are missing.
Correction: Replace.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
16c - ALKALINITY (Pf)
The total alkalinity is 200 ppm.
Correction: Maintain the total alkalinity between 60 and 180 ppm.
Code ATCP 76.14(5)(d)
-
Not serious
Action taken: Operator attached rope at
Corrected on site
26h - RESCUE EQUIPMENT - ACCESSIBLE, GOOD REPAIR, SIZED (P)
Ring buoy is on site, but rope is not attached.
Correction: Mount properly sized ring buoy, position in a consipicuous place that is readily accessible, and maintain in good repair with rope attached.
Code ATCP 76.26(1)
-
Not serious
Action taken: Operator to contact repair
31b - EQUIPMENT NOT LOCATED/INSTALLED/MAINTAINED/ REPAIRED
Pool recirculation pump has a slow leak.
Correction: Properly locate, intall, maintain and repair equipment.
Code ATCP 76.33(1)(e)
-
Not serious
Action taken:
-
Jul 11, 2024 Re-Inspection · No Reinspection Required
-
Not serious
Action taken: Falling piece of trim remo
31b - EQUIPMENT NOT MAINTAINED - Not Corrected
Pool railing closest to the shepherd's crook is loose, and piece of trim is falling down in the corner of the pool closest to the ring buoy.
Correction: Repair and maintain all equipment. Securely fasten all pool railing.
Code ATCP 76.33(1)(e)
-
Not serious
Action taken: Falling piece of trim remo
-
Jun 25, 2024 Routine Inspection · Reinspection Required
-
Not serious
Action taken:
06a - SPARE STRAINER BASKET
A spare strainer basket(s) or screen for the skimmers and the recirculation pump is not located on site.
Correction: Provide a spare basket or screen.
Code ATCP 76.11(2)(d)
-
Not serious
Action taken:
09a - FLOW METER
The flow meter is stuck and is not functional.
Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.
Code ATCP 76.11(5)
-
Not serious
Action taken:
14e - WATER POTENTIAL ORP
The water potential was 926 mV at the time of the inspection.
Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.
Code ATCP 76.14(5)(a)
-
Not serious
Action taken:
26s - BIOHAZARD SAFETY KIT
No biohazard safety kit is located on the premises.
Correction: Provide a biohazard safety kit at the first aid station.
Code ATCP 76.27(2)
-
Not serious
Action taken:
30e - SOAP
There is no soap dispenser or soap in the gender neutral restroom.
Correction: Provide soap at all hand washing sinks and showers.
Code ATCP 76.33(2)(e)
-
Not serious
Action taken:
31b - EQUIPMENT NOT MAINTAINED
Pool railing closest to the shepherd's crook is loose, and piece of trim is falling down in the corner of the pool closest to the ring buoy.
Correction: Repair and maintain all equipment. Securely fasten all pool railing.
Code ATCP 76.33(1)(e)
-
Not serious
Other
34e - VGBA COVERS
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
-
Jun 16, 2023 Re-Inspection · No Reinspection Required
-
Not serious
Action taken: PIC informed items ordered
04c - SKIMMER BASKET/WEIR - Not Corrected
The spare skimmer basket and weir door is missing on the edge of the pool closest to the restrooms.
Correction: Replace.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken: PIC informed order has bee
26i - RESCUE EQUIPMENT - MISSING - Not Corrected
A ring buoy is missing from the facility. The pool basin is over 30 feet in width at 46 feet.
Correction: Provide a ring buoy for the facility and mount it in a conspicuous location.
Code ATCP 76.26(1)(b)
-
Not serious
Action taken: PIC informed order has bee
26r - BLANKETS MISSING - Not Corrected
2 durable blankets are not available in the pool area.
Correction: Provide 2 durable blankets in the pool area.
Code ATCP 76.27(1)
-
Not serious
Action taken:
27d - SIGNAGE - NO DIVING - Not Corrected
'NO DIVING' is not posted in the pool rules.
Correction: Post approved signage with letters at least 4 inches in height.
Code ATCP 76.29(1)(c)
-
Not serious
Action taken: Signage was printed and po
Corrected on site
29g - DRINKING FOUNTAIN - Not Corrected
The drinking fountain has been removed from the pool area.
Correction: Repair/clean the drinking fountain.
Code ATCP 76.33(1)(g)
-
Not serious
Action taken: PIC informed items ordered
-
Jun 14, 2023 Routine Inspection · Reinspection Required
-
Not serious
Action taken:
04c - SKIMMER BASKET/WEIR
The spare skimmer basket and weir door is missing on the edge of the pool closest to the restrooms.
Correction: Replace.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken: PIC added chlorine and whe
14a - CHLORINE TOO LOW
The chlorine residual was 0.6-0.8ppm at the time of the inspection.
Correction: Close the pool and raise the chlorine residual. Call inspector to schedule a reopening inspection.
Code ATCP 76.14(4)(a)
-
Not serious
Action taken: PIC increased water potent
Corrected on site
14e - WATER POTENTIAL ORP
The water potential was in the 500smV at the time of the inspection.
Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.
Code ATCP 76.14(5)(a)
-
Not serious
Action taken: PIC calculated patron load
Corrected on site
26f - PATRON LOAD - NOT POSTED
The maximum patron load is not posted. The patron load has washed off of the designated sign.
Correction: Post the maximum patron load.
Code ATCP 76.29(1)(d)
-
Not serious
Action taken: PIC informed order has bee
26i - RESCUE EQUIPMENT - MISSING
A ring buoy is missing from the facility. The pool basin is over 30 feet in width at 46 feet.
Correction: Provide a ring buoy for the facility and mount it in a conspicuous location.
Code ATCP 76.26(1)(b)
-
Not serious
Action taken: PIC informed order has bee
26r - BLANKETS MISSING
2 durable blankets are not available in the pool area.
Correction: Provide 2 durable blankets in the pool area.
Code ATCP 76.27(1)
-
Not serious
Action taken:
27d - SIGNAGE - NO DIVING
'NO DIVING' is not posted in the pool rules.
Correction: Post approved signage with letters at least 4 inches in height.
Code ATCP 76.29(1)(c)
-
Not serious
Any of the following conditions or situa
Corrected on site
28a - CLOSING CRITERIA
The pool was not closed under the following condition: 3) chlorine was at 0.6-0.8 at the time of inspection. According to the pool log and PIC, the pool was tested this morning and was under 1ppm and still opened. According to the pool log there were several days in June where chlorine was under 1ppm and pool was open.
Correction: Ensure that the closing criteria are adhered to under the listed below.
Code ATCP 76.30
-
Not serious
Action taken: Signage was printed and po
Corrected on site
29g - DRINKING FOUNTAIN
The drinking fountain has been removed from the pool area.
Correction: Repair/clean the drinking fountain.
Code ATCP 76.33(1)(g)
-
Not serious
Action taken: Soap provided in bathroom.
Corrected on site
30e - SOAP
The soap dispenser in bathroom has been removed from bathroom. There is no soap.
Correction: Provide soap at all hand washing sinks and showers.
Code ATCP 76.33(2)(e)
-
Not serious
Action taken: Paper towel provided.
Corrected on site
30f - HAND TOWELS
No hand towels are available at the bathroom hand washing sink.
Correction: Provide hand drying provisions at all hand washing sinks.
Code ATCP 76.33(2)(f)
-
Not serious
Action taken: Maintenance adjusted door,
34c - DOOR/GATE
The gate to the pool enclosure near the restroom is not consistently self-latching. When opened and then closed door occasionally does not latch, especially when opened to a lesser degree.
Correction: Repair the door immediately so that it is self-closing, self-latching, and is lockable.
Code ATCP 76.34(4)
-
Not serious
Other
34e - VGBA COVERS
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
-
Aug 19, 2021 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 23, 2020 Re-Inspection · No Reinspection Required
No violations cited.
-
Jun 16, 2020 Pre-Inspection · Reinspection Required
No violations cited.
Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.