RecordWell Data

The Vue At Pinnacle Park

1300 POST RD, Fitchburg, WI 53713 · Dane County

35cited violations
0serious tier
9inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
LICSWD-2020-00162
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026150
2025140
2024280
20232180
2021100
2020200

Inspections

  1. May 26, 2026 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      04c - SKIMMER BASKET/WEIR

      Both skimmer weir doors are missing.

      Correction: Replace.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken:

      16c - ALKALINITY (Pf)

      The total alkalinity is 200 ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(5)(d)

    • Not serious Action taken: Operator attached rope at Corrected on site

      26h - RESCUE EQUIPMENT - ACCESSIBLE, GOOD REPAIR, SIZED (P)

      Ring buoy is on site, but rope is not attached.

      Correction: Mount properly sized ring buoy, position in a consipicuous place that is readily accessible, and maintain in good repair with rope attached.

      Code ATCP 76.26(1)

    • Not serious Action taken:

      30f - HAND DRYING DEVICES (Pf)

      No hand drying devices are available at the hand washing sink in the restroom. Batteries in paper towel dispenser need to be replaced.

      Correction: Provide individual towels in dispensers or hot air dryers at hand washing sinks.

      Code ATCP 76.33(2)(f)

    • Not serious Action taken: Operator to contact repair

      31b - EQUIPMENT NOT LOCATED/INSTALLED/MAINTAINED/ REPAIRED

      Pool recirculation pump has a slow leak.

      Correction: Properly locate, intall, maintain and repair equipment.

      Code ATCP 76.33(1)(e)

  2. Jun 4, 2025 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      04c - SKIMMER BASKET/WEIR

      Both skimmer weir doors are missing.

      Correction: Replace.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken:

      16c - ALKALINITY (Pf)

      The total alkalinity is 200 ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(5)(d)

    • Not serious Action taken: Operator attached rope at Corrected on site

      26h - RESCUE EQUIPMENT - ACCESSIBLE, GOOD REPAIR, SIZED (P)

      Ring buoy is on site, but rope is not attached.

      Correction: Mount properly sized ring buoy, position in a consipicuous place that is readily accessible, and maintain in good repair with rope attached.

      Code ATCP 76.26(1)

    • Not serious Action taken: Operator to contact repair

      31b - EQUIPMENT NOT LOCATED/INSTALLED/MAINTAINED/ REPAIRED

      Pool recirculation pump has a slow leak.

      Correction: Properly locate, intall, maintain and repair equipment.

      Code ATCP 76.33(1)(e)

  3. Jul 11, 2024 Re-Inspection · No Reinspection Required
    • Not serious Action taken: Falling piece of trim remo

      31b - EQUIPMENT NOT MAINTAINED - Not Corrected

      Pool railing closest to the shepherd's crook is loose, and piece of trim is falling down in the corner of the pool closest to the ring buoy.

      Correction: Repair and maintain all equipment. Securely fasten all pool railing.

      Code ATCP 76.33(1)(e)

  4. Jun 25, 2024 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      06a - SPARE STRAINER BASKET

      A spare strainer basket(s) or screen for the skimmers and the recirculation pump is not located on site.

      Correction: Provide a spare basket or screen.

      Code ATCP 76.11(2)(d)

    • Not serious Action taken:

      09a - FLOW METER

      The flow meter is stuck and is not functional.

      Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken:

      14e - WATER POTENTIAL ORP

      The water potential was 926 mV at the time of the inspection.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.

      Code ATCP 76.14(5)(a)

    • Not serious Action taken:

      26s - BIOHAZARD SAFETY KIT

      No biohazard safety kit is located on the premises.

      Correction: Provide a biohazard safety kit at the first aid station.

      Code ATCP 76.27(2)

    • Not serious Action taken:

      30e - SOAP

      There is no soap dispenser or soap in the gender neutral restroom.

      Correction: Provide soap at all hand washing sinks and showers.

      Code ATCP 76.33(2)(e)

    • Not serious Action taken:

      31b - EQUIPMENT NOT MAINTAINED

      Pool railing closest to the shepherd's crook is loose, and piece of trim is falling down in the corner of the pool closest to the ring buoy.

      Correction: Repair and maintain all equipment. Securely fasten all pool railing.

      Code ATCP 76.33(1)(e)

    • Not serious Other

      34e - VGBA COVERS

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  5. Jun 16, 2023 Re-Inspection · No Reinspection Required
    • Not serious Action taken: PIC informed items ordered

      04c - SKIMMER BASKET/WEIR - Not Corrected

      The spare skimmer basket and weir door is missing on the edge of the pool closest to the restrooms.

      Correction: Replace.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken: PIC informed order has bee

      26i - RESCUE EQUIPMENT - MISSING - Not Corrected

      A ring buoy is missing from the facility. The pool basin is over 30 feet in width at 46 feet.

      Correction: Provide a ring buoy for the facility and mount it in a conspicuous location.

      Code ATCP 76.26(1)(b)

    • Not serious Action taken: PIC informed order has bee

      26r - BLANKETS MISSING - Not Corrected

      2 durable blankets are not available in the pool area.

      Correction: Provide 2 durable blankets in the pool area.

      Code ATCP 76.27(1)

    • Not serious Action taken:

      27d - SIGNAGE - NO DIVING - Not Corrected

      'NO DIVING' is not posted in the pool rules.

      Correction: Post approved signage with letters at least 4 inches in height.

      Code ATCP 76.29(1)(c)

    • Not serious Action taken: Signage was printed and po Corrected on site

      29g - DRINKING FOUNTAIN - Not Corrected

      The drinking fountain has been removed from the pool area.

      Correction: Repair/clean the drinking fountain.

      Code ATCP 76.33(1)(g)

  6. Jun 14, 2023 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      04c - SKIMMER BASKET/WEIR

      The spare skimmer basket and weir door is missing on the edge of the pool closest to the restrooms.

      Correction: Replace.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken: PIC added chlorine and whe

      14a - CHLORINE TOO LOW

      The chlorine residual was 0.6-0.8ppm at the time of the inspection.

      Correction: Close the pool and raise the chlorine residual. Call inspector to schedule a reopening inspection.

      Code ATCP 76.14(4)(a)

    • Not serious Action taken: PIC increased water potent Corrected on site

      14e - WATER POTENTIAL ORP

      The water potential was in the 500smV at the time of the inspection.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.

      Code ATCP 76.14(5)(a)

    • Not serious Action taken: PIC calculated patron load Corrected on site

      26f - PATRON LOAD - NOT POSTED

      The maximum patron load is not posted. The patron load has washed off of the designated sign.

      Correction: Post the maximum patron load.

      Code ATCP 76.29(1)(d)

    • Not serious Action taken: PIC informed order has bee

      26i - RESCUE EQUIPMENT - MISSING

      A ring buoy is missing from the facility. The pool basin is over 30 feet in width at 46 feet.

      Correction: Provide a ring buoy for the facility and mount it in a conspicuous location.

      Code ATCP 76.26(1)(b)

    • Not serious Action taken: PIC informed order has bee

      26r - BLANKETS MISSING

      2 durable blankets are not available in the pool area.

      Correction: Provide 2 durable blankets in the pool area.

      Code ATCP 76.27(1)

    • Not serious Action taken:

      27d - SIGNAGE - NO DIVING

      'NO DIVING' is not posted in the pool rules.

      Correction: Post approved signage with letters at least 4 inches in height.

      Code ATCP 76.29(1)(c)

    • Not serious Any of the following conditions or situa Corrected on site

      28a - CLOSING CRITERIA

      The pool was not closed under the following condition: 3) chlorine was at 0.6-0.8 at the time of inspection. According to the pool log and PIC, the pool was tested this morning and was under 1ppm and still opened. According to the pool log there were several days in June where chlorine was under 1ppm and pool was open.

      Correction: Ensure that the closing criteria are adhered to under the listed below.

      Code ATCP 76.30

    • Not serious Action taken: Signage was printed and po Corrected on site

      29g - DRINKING FOUNTAIN

      The drinking fountain has been removed from the pool area.

      Correction: Repair/clean the drinking fountain.

      Code ATCP 76.33(1)(g)

    • Not serious Action taken: Soap provided in bathroom. Corrected on site

      30e - SOAP

      The soap dispenser in bathroom has been removed from bathroom. There is no soap.

      Correction: Provide soap at all hand washing sinks and showers.

      Code ATCP 76.33(2)(e)

    • Not serious Action taken: Paper towel provided. Corrected on site

      30f - HAND TOWELS

      No hand towels are available at the bathroom hand washing sink.

      Correction: Provide hand drying provisions at all hand washing sinks.

      Code ATCP 76.33(2)(f)

    • Not serious Action taken: Maintenance adjusted door,

      34c - DOOR/GATE

      The gate to the pool enclosure near the restroom is not consistently self-latching. When opened and then closed door occasionally does not latch, especially when opened to a lesser degree.

      Correction: Repair the door immediately so that it is self-closing, self-latching, and is lockable.

      Code ATCP 76.34(4)

    • Not serious Other

      34e - VGBA COVERS

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  7. Aug 19, 2021 Routine Inspection · No Reinspection Required

    No violations cited.

  8. Jun 23, 2020 Re-Inspection · No Reinspection Required

    No violations cited.

  9. Jun 16, 2020 Pre-Inspection · Reinspection Required

    No violations cited.

Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.