Tpc Wisconsin
5000 N SHERMAN AVE, Madison, WI 53704 · Dane County
Establishment
- Type
- Pool / recreational water (Swimming Pool)
- Inspected by
- Public Health Madison & Dane County
- License / ID
- 72936-81089
- Official record
- Public Health Madison & Dane County inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 5 | 0 |
| 2025 | 2 | 8 | 0 |
| 2024 | 3 | 20 | 0 |
| 2021 | 1 | 0 | 0 |
| 2019 | 1 | 0 | 0 |
| 2018 | 2 | 0 | 0 |
| 2016 | 1 | 0 | 0 |
| 2015 | 1 | 0 | 0 |
| 2014 | 2 | 0 | 0 |
| 2013 | 1 | 0 | 0 |
Inspections
-
Aug 19, 2026 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
16c - ALKALINITY (Pf)
The total alkalinity is 200ppm.
Correction: Maintain the total alkalinity between 60 and 180 ppm.
Code ATCP 76.14(5)(d)
-
Not serious
Action taken:
25f - LIFEGUARD - CERTIFICATIONS MAINTAINED (P)
Some lifeguards do not have the annual CPR/first-aid required to be a lifeguard.
Correction: The lifeguard must be relieved of duties until a current certification can be verified. If the minimum lifeguard requirements in the approved staffing plan are not met as a result, the guarded pool or portion must be closed.
Code ATCP 76.22(2)(a)
-
Not serious
Action taken:
26t - BIOHAZARD SAFETY KIT (Pf)
No biohazard safety kit is located at the first aid station or on the premises.
Correction: Provide a biohazard safety kit with the items listed in ATCP 76.27(2)(b) at the first aid station or on the premise. 1. Scoop and spatula. 2. Sanitizing hand wipes. 3. Sanitizing surface wipes. 4. Neoprene gloves. 5. Paper toweling. 6. Biohazard disposal bag at least 24"X24". 7. Twist tie or other effective means to close the bag. 8. Biohazard sorbent. 9. Storage case.
Code ATCP 76.27(2)
-
Not serious
Action taken:
29b - BASIN MAINTENANCE AND REPAIR
The pool basin is flaking at the bottom. Pieces of the basin sides are detaching from the wall.
Correction: Maintain the pool basin in a clean, sanitary condition and free from cracks and defects.
Code ATCP 76.33(1)(a)
-
Not serious
Other
34f - VGBA COVERS DOCUMENTATION (Pf)
No documentation is available on site for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date.
Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.
Code ATCP 76.38
-
Not serious
Action taken:
-
Aug 6, 2025 Routine Inspection · No Reinspection Required
-
Not serious
Action taken: Operator added signage.
Corrected on site
26g - BREATH HOLDING PROHIBITION - SIGNAGE
Breath holding prohibition is not posted or communicated to patrons.
Correction: Provide signage or otherwise communicate to patrons that activites involving prolonged breath holding are prohibited.
Code ATCP 76.29(1)(f)
-
Not serious
Action taken: Instructions were updated.
Corrected on site
26p - EMERGENCY NUMBERS AND ADDRESS (Pf)
The emergency phone does not have correct dialing instructions.
Correction: Post the emergency numbers near or attached to the designated emergency phone.
Code ATCP 76.26(2)(d)
-
Not serious
Action taken:
28e -REPORTS AND RECORDS (Pf)
Testing log reports are missing combine chlorine, alkalinity, and cyanuric acid.
Correction: Keep the following records available for review. (a) Chemical testing pursuant s. ATCP 76.14. (b) Backwashing completion. (c) Breakpoint chlorination. (d) Interlock testing. (e) Anti-entrapment system testing. (f) Water temperature. (g) Safety and rescue equipment maintaining pursuant to ss. ATCP 76.26 and ATCP 76.27. (h) If monthly reports are requested by the department or its agent, they shall
Code ATCP 76.32(1)
-
Not serious
Other
34f - VGBA COVERS DOCUMENTATION (Pf)
Middle grate was missing two screws. No documentation is available on site for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date.
Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.
Code ATCP 76.38
-
Not serious
Action taken: Operator added signage.
Corrected on site
-
Aug 6, 2025 Routine Inspection · No Reinspection Required
-
Not serious
Action taken: Operator added signage.
Corrected on site
26g - BREATH HOLDING PROHIBITION - SIGNAGE
Breath holding prohibition is not posted or communicated to patrons.
Correction: Provide signage or otherwise communicate to patrons that activites involving prolonged breath holding are prohibited.
Code ATCP 76.29(1)(f)
-
Not serious
Action taken: Instructions were updated.
Corrected on site
26p - EMERGENCY NUMBERS AND ADDRESS (Pf)
The emergency phone does not have correct dialing instructions.
Correction: Post the emergency numbers near or attached to the designated emergency phone.
Code ATCP 76.26(2)(d)
-
Not serious
Action taken:
28e -REPORTS AND RECORDS (Pf)
Testing log reports are missing combine chlorine, alkalinity, and cyanuric acid.
Correction: Keep the following records available for review. (a) Chemical testing pursuant s. ATCP 76.14. (b) Backwashing completion. (c) Breakpoint chlorination. (d) Interlock testing. (e) Anti-entrapment system testing. (f) Water temperature. (g) Safety and rescue equipment maintaining pursuant to ss. ATCP 76.26 and ATCP 76.27. (h) If monthly reports are requested by the department or its agent, they shall
Code ATCP 76.32(1)
-
Not serious
Other
34f - VGBA COVERS DOCUMENTATION (Pf)
Middle grate was missing two screws. No documentation is available on site for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date.
Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.
Code ATCP 76.38
-
Not serious
Action taken: Operator added signage.
Corrected on site
-
Jul 18, 2024 Re-Inspection · No Reinspection Required
-
Not serious
Action taken:
14e - WATER POTENTIAL ORP - Not Corrected
The water potential was 405mV at the time of the inspection.
Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.
Code ATCP 76.14(5)(a)
-
Not serious
Action taken: Ensure combined chlorine i
20c - WATER TESTING - POOLS - Not Corrected
The water testing frequency for combined chlorine is not in compliance with ATCP 76.18(1).
Correction: Perform water testing in accordance with ATCP 76.18(1).
Code ATCP 76.18(1)
-
Not serious
Action taken:
31a - WALLS, CEILING AND FLOORS - Not Corrected
Cracks and divots were observed throughout the pool deck area.
Correction: Maintain the walls, ceilings, and floors in a clean and sanitary condition.
Code ATCP 76.33(1)(c)
-
Not serious
Action taken:
-
Jul 17, 2024 Re-Inspection · Reinspection Required
-
Not serious
Action taken:
14e - WATER POTENTIAL ORP - Not Corrected
The water potential was 405mV at the time of the inspection.
Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.
Code ATCP 76.14(5)(a)
-
Not serious
Action taken: Ensure combined chlorine i
20c - WATER TESTING - POOLS - Not Corrected
The water testing frequency for combined chlorine is not in compliance with ATCP 76.18(1).
Correction: Perform water testing in accordance with ATCP 76.18(1).
Code ATCP 76.18(1)
-
Not serious
Action taken:
31a - WALLS, CEILING AND FLOORS - Not Corrected
Cracks and divots were observed throughout the pool deck area.
Correction: Maintain the walls, ceilings, and floors in a clean and sanitary condition.
Code ATCP 76.33(1)(c)
-
Not serious
Action taken:
34a - GATES NOT MAINTAINED - Not Corrected
Fence has a gap near the pump room that prevents the pool from being secure.
Correction: Repair and maintain the gate or door.
Code ATCP 76.34(2)
-
Not serious
Action taken:
-
Jul 9, 2024 Routine Inspection · Reinspection Required
-
Not serious
Action taken:
06a - SPARE STRAINER BASKET
A spare strainer basket(s) or screen for the skimmers is not located on site.
Correction: Provide a spare basket or screen.
Code ATCP 76.11(2)(d)
-
Not serious
Action taken:
Corrected on site
06b - STRAINER BASKET CLEANED
Multiple strainer baskets for the pool have accumulation of debris and dead frogs.
Correction: Clean strainer baskets and screens daily to prevent the accumulation of debris.
Code ATCP 76.11(2)(d)
-
Not serious
Action taken:
11e - SDS AVAILABILITY
Safety data sheets are not available for all chemicals used in the facility.
Correction: Provide safety data sheets for all chemicals used in the facility.
Code ATCP 76.12(4)(b)
-
Not serious
Action taken: Chlorine was remeasured at
Corrected on site
14a - CHLORINE TOO LOW
The chlorine residual was 0.6ppm at the time of the inspection.
Correction: Close the pool and raise the chlorine residual to 1.0ppm. Call inspector to schedule a reopening inspection.
Code ATCP 76.14(4)(a)
-
Not serious
Action taken:
14e - WATER POTENTIAL ORP
The water potential was 160mV at the time of the inspection.
Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.
Code ATCP 76.14(5)(a)
-
Not serious
Action taken:
20c - WATER TESTING - POOLS
The water testing frequency for combined chlorine and alkalinity is not in compliance with ATCP 76.18(1).
Correction: Perform water testing in accordance with ATCP 76.18(1).
Code ATCP 76.18(1)
-
Not serious
Action taken:
24a - LIFEGUARD - STAFFING PLAN
The lifeguard staffing plan does not include a diagram for both average and maximum capacity, and method of communication between 2 or more lifeguards.
Correction: Create a written plan pursuant to the requirements of ATCP 76.22 and submit it for approval.
Code ATCP 76.22(1)(a)
-
Not serious
Action taken:
25d - LIFEGUARD - APPROVED CERTIFICATION
Certification for multiple staff members is not from an approved course (Aquaheroes Academy).
Correction: The lifeguards must be relieved of duties until the certification from am approved course can be verified. If the minimum lifeguard requirements in the approved staffing plan are not met as a result, the guarded pool or portion must be closed.
Code ATCP 76.22(2)(a)
-
Not serious
Action taken:
Corrected on site
26f - PATRON LOAD - NOT POSTED
The maximum patron load is not posted in the facility.
Correction: Post the maximum patron load.
Code ATCP 76.29(1)(d)
-
Not serious
Action taken:
26o - EMERGENCY NUMBERS AND ADDRESS
The emergency numbers and the facility's location are not posted near the designated emergency phone.
Correction: Post the emergency numbers near the designated emergency phone.
Code ATCP 76.26(2)
-
Not serious
Action taken:
31a - WALLS, CEILING AND FLOORS
Cracks and divots were observed throughout the pool deck area.
Correction: Maintain the walls, ceilings, and floors in a clean and sanitary condition.
Code ATCP 76.33(1)(c)
-
Not serious
Action taken:
34a - GATES NOT MAINTAINED
Pool gate and fence located near the pump room was observed to be in poor repair. Gate/fence secured to existing fence using zip ties, but there is still a gap that prevents the pool from being secure.
Correction: Repair and maintain the gate or door.
Code ATCP 76.34(2)
-
Not serious
Other
34e - VGBA COVERS
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
-
Aug 26, 2021 Routine Inspection · No Reinspection Required
No violations cited.
-
Aug 28, 2019 Routine Inspection · No Reinspection Required
No violations cited.
-
Aug 2, 2018 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 1, 2018 Routine Inspection · No Reinspection Required
No violations cited.
-
Aug 22, 2016 Routine Inspection · No Reinspection Required
No violations cited.
-
Aug 3, 2015 Routine Inspection · No Reinspection Required
No violations cited.
-
Aug 18, 2014 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 24, 2014 Routine Inspection · Reinspection Required
No violations cited.
-
Jun 11, 2013 Routine Inspection · No Reinspection Required
No violations cited.
Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.