Tpc Wisconsin

5000 N SHERMAN AVE, Madison, WI 53704 · Dane County

33cited violations
0serious tier
15inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
72936-81089
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026150
2025280
20243200
2021100
2019100
2018200
2016100
2015100
2014200
2013100

Inspections

  1. Aug 19, 2026 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      16c - ALKALINITY (Pf)

      The total alkalinity is 200ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(5)(d)

    • Not serious Action taken:

      25f - LIFEGUARD - CERTIFICATIONS MAINTAINED (P)

      Some lifeguards do not have the annual CPR/first-aid required to be a lifeguard.

      Correction: The lifeguard must be relieved of duties until a current certification can be verified. If the minimum lifeguard requirements in the approved staffing plan are not met as a result, the guarded pool or portion must be closed.

      Code ATCP 76.22(2)(a)

    • Not serious Action taken:

      26t - BIOHAZARD SAFETY KIT (Pf)

      No biohazard safety kit is located at the first aid station or on the premises.

      Correction: Provide a biohazard safety kit with the items listed in ATCP 76.27(2)(b) at the first aid station or on the premise. 1. Scoop and spatula. 2. Sanitizing hand wipes. 3. Sanitizing surface wipes. 4. Neoprene gloves. 5. Paper toweling. 6. Biohazard disposal bag at least 24"X24". 7. Twist tie or other effective means to close the bag. 8. Biohazard sorbent. 9. Storage case.

      Code ATCP 76.27(2)

    • Not serious Action taken:

      29b - BASIN MAINTENANCE AND REPAIR

      The pool basin is flaking at the bottom. Pieces of the basin sides are detaching from the wall.

      Correction: Maintain the pool basin in a clean, sanitary condition and free from cracks and defects.

      Code ATCP 76.33(1)(a)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf)

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date.

      Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.

      Code ATCP 76.38

  2. Aug 6, 2025 Routine Inspection · No Reinspection Required
    • Not serious Action taken: Operator added signage. Corrected on site

      26g - BREATH HOLDING PROHIBITION - SIGNAGE

      Breath holding prohibition is not posted or communicated to patrons.

      Correction: Provide signage or otherwise communicate to patrons that activites involving prolonged breath holding are prohibited.

      Code ATCP 76.29(1)(f)

    • Not serious Action taken: Instructions were updated. Corrected on site

      26p - EMERGENCY NUMBERS AND ADDRESS (Pf)

      The emergency phone does not have correct dialing instructions.

      Correction: Post the emergency numbers near or attached to the designated emergency phone.

      Code ATCP 76.26(2)(d)

    • Not serious Action taken:

      28e -REPORTS AND RECORDS (Pf)

      Testing log reports are missing combine chlorine, alkalinity, and cyanuric acid.

      Correction: Keep the following records available for review. (a) Chemical testing pursuant s. ATCP 76.14. (b) Backwashing completion. (c) Breakpoint chlorination. (d) Interlock testing. (e) Anti-entrapment system testing. (f) Water temperature. (g) Safety and rescue equipment maintaining pursuant to ss. ATCP 76.26 and ATCP 76.27. (h) If monthly reports are requested by the department or its agent, they shall

      Code ATCP 76.32(1)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf)

      Middle grate was missing two screws. No documentation is available on site for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date.

      Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.

      Code ATCP 76.38

  3. Aug 6, 2025 Routine Inspection · No Reinspection Required
    • Not serious Action taken: Operator added signage. Corrected on site

      26g - BREATH HOLDING PROHIBITION - SIGNAGE

      Breath holding prohibition is not posted or communicated to patrons.

      Correction: Provide signage or otherwise communicate to patrons that activites involving prolonged breath holding are prohibited.

      Code ATCP 76.29(1)(f)

    • Not serious Action taken: Instructions were updated. Corrected on site

      26p - EMERGENCY NUMBERS AND ADDRESS (Pf)

      The emergency phone does not have correct dialing instructions.

      Correction: Post the emergency numbers near or attached to the designated emergency phone.

      Code ATCP 76.26(2)(d)

    • Not serious Action taken:

      28e -REPORTS AND RECORDS (Pf)

      Testing log reports are missing combine chlorine, alkalinity, and cyanuric acid.

      Correction: Keep the following records available for review. (a) Chemical testing pursuant s. ATCP 76.14. (b) Backwashing completion. (c) Breakpoint chlorination. (d) Interlock testing. (e) Anti-entrapment system testing. (f) Water temperature. (g) Safety and rescue equipment maintaining pursuant to ss. ATCP 76.26 and ATCP 76.27. (h) If monthly reports are requested by the department or its agent, they shall

      Code ATCP 76.32(1)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf)

      Middle grate was missing two screws. No documentation is available on site for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date.

      Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.

      Code ATCP 76.38

  4. Jul 18, 2024 Re-Inspection · No Reinspection Required
    • Not serious Action taken:

      14e - WATER POTENTIAL ORP - Not Corrected

      The water potential was 405mV at the time of the inspection.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.

      Code ATCP 76.14(5)(a)

    • Not serious Action taken: Ensure combined chlorine i

      20c - WATER TESTING - POOLS - Not Corrected

      The water testing frequency for combined chlorine is not in compliance with ATCP 76.18(1).

      Correction: Perform water testing in accordance with ATCP 76.18(1).

      Code ATCP 76.18(1)

    • Not serious Action taken:

      31a - WALLS, CEILING AND FLOORS - Not Corrected

      Cracks and divots were observed throughout the pool deck area.

      Correction: Maintain the walls, ceilings, and floors in a clean and sanitary condition.

      Code ATCP 76.33(1)(c)

  5. Jul 17, 2024 Re-Inspection · Reinspection Required
    • Not serious Action taken:

      14e - WATER POTENTIAL ORP - Not Corrected

      The water potential was 405mV at the time of the inspection.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.

      Code ATCP 76.14(5)(a)

    • Not serious Action taken: Ensure combined chlorine i

      20c - WATER TESTING - POOLS - Not Corrected

      The water testing frequency for combined chlorine is not in compliance with ATCP 76.18(1).

      Correction: Perform water testing in accordance with ATCP 76.18(1).

      Code ATCP 76.18(1)

    • Not serious Action taken:

      31a - WALLS, CEILING AND FLOORS - Not Corrected

      Cracks and divots were observed throughout the pool deck area.

      Correction: Maintain the walls, ceilings, and floors in a clean and sanitary condition.

      Code ATCP 76.33(1)(c)

    • Not serious Action taken:

      34a - GATES NOT MAINTAINED - Not Corrected

      Fence has a gap near the pump room that prevents the pool from being secure.

      Correction: Repair and maintain the gate or door.

      Code ATCP 76.34(2)

  6. Jul 9, 2024 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      06a - SPARE STRAINER BASKET

      A spare strainer basket(s) or screen for the skimmers is not located on site.

      Correction: Provide a spare basket or screen.

      Code ATCP 76.11(2)(d)

    • Not serious Action taken: Corrected on site

      06b - STRAINER BASKET CLEANED

      Multiple strainer baskets for the pool have accumulation of debris and dead frogs.

      Correction: Clean strainer baskets and screens daily to prevent the accumulation of debris.

      Code ATCP 76.11(2)(d)

    • Not serious Action taken:

      11e - SDS AVAILABILITY

      Safety data sheets are not available for all chemicals used in the facility.

      Correction: Provide safety data sheets for all chemicals used in the facility.

      Code ATCP 76.12(4)(b)

    • Not serious Action taken: Chlorine was remeasured at Corrected on site

      14a - CHLORINE TOO LOW

      The chlorine residual was 0.6ppm at the time of the inspection.

      Correction: Close the pool and raise the chlorine residual to 1.0ppm. Call inspector to schedule a reopening inspection.

      Code ATCP 76.14(4)(a)

    • Not serious Action taken:

      14e - WATER POTENTIAL ORP

      The water potential was 160mV at the time of the inspection.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.

      Code ATCP 76.14(5)(a)

    • Not serious Action taken:

      20c - WATER TESTING - POOLS

      The water testing frequency for combined chlorine and alkalinity is not in compliance with ATCP 76.18(1).

      Correction: Perform water testing in accordance with ATCP 76.18(1).

      Code ATCP 76.18(1)

    • Not serious Action taken:

      24a - LIFEGUARD - STAFFING PLAN

      The lifeguard staffing plan does not include a diagram for both average and maximum capacity, and method of communication between 2 or more lifeguards.

      Correction: Create a written plan pursuant to the requirements of ATCP 76.22 and submit it for approval.

      Code ATCP 76.22(1)(a)

    • Not serious Action taken:

      25d - LIFEGUARD - APPROVED CERTIFICATION

      Certification for multiple staff members is not from an approved course (Aquaheroes Academy).

      Correction: The lifeguards must be relieved of duties until the certification from am approved course can be verified. If the minimum lifeguard requirements in the approved staffing plan are not met as a result, the guarded pool or portion must be closed.

      Code ATCP 76.22(2)(a)

    • Not serious Action taken: Corrected on site

      26f - PATRON LOAD - NOT POSTED

      The maximum patron load is not posted in the facility.

      Correction: Post the maximum patron load.

      Code ATCP 76.29(1)(d)

    • Not serious Action taken:

      26o - EMERGENCY NUMBERS AND ADDRESS

      The emergency numbers and the facility's location are not posted near the designated emergency phone.

      Correction: Post the emergency numbers near the designated emergency phone.

      Code ATCP 76.26(2)

    • Not serious Action taken:

      31a - WALLS, CEILING AND FLOORS

      Cracks and divots were observed throughout the pool deck area.

      Correction: Maintain the walls, ceilings, and floors in a clean and sanitary condition.

      Code ATCP 76.33(1)(c)

    • Not serious Action taken:

      34a - GATES NOT MAINTAINED

      Pool gate and fence located near the pump room was observed to be in poor repair. Gate/fence secured to existing fence using zip ties, but there is still a gap that prevents the pool from being secure.

      Correction: Repair and maintain the gate or door.

      Code ATCP 76.34(2)

    • Not serious Other

      34e - VGBA COVERS

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  7. Aug 26, 2021 Routine Inspection · No Reinspection Required

    No violations cited.

  8. Aug 28, 2019 Routine Inspection · No Reinspection Required

    No violations cited.

  9. Aug 2, 2018 Routine Inspection · No Reinspection Required

    No violations cited.

  10. Jun 1, 2018 Routine Inspection · No Reinspection Required

    No violations cited.

  11. Aug 22, 2016 Routine Inspection · No Reinspection Required

    No violations cited.

  12. Aug 3, 2015 Routine Inspection · No Reinspection Required

    No violations cited.

  13. Aug 18, 2014 Routine Inspection · No Reinspection Required

    No violations cited.

  14. Jun 24, 2014 Routine Inspection · Reinspection Required

    No violations cited.

  15. Jun 11, 2013 Routine Inspection · No Reinspection Required

    No violations cited.

Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.