Dec 10, 2025 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
09a - FLOW METER (P
The flow meter is not functional or installed properly. Flowmeter indicates that the flowrate is >80gpm and this whirlpool was designed to have a flowrate of 49gpm.
Correction: Repair, replace, or install the flowmeter so an accurate rate of flow can be recorded.
Code ATCP 76.11(5)
-
Not serious
Action taken: sanitarian suggested using
11b - CHEMICAL - STORAGE (P)(Pf)
Chemicals are improperly stored in accordance with ATCP 76.12(2). No overspill protection to prevent chlorine from mixing with acid in chemical storage room.
Correction: Store chemicals in accordance with ATCP 76.12(2).
Code ATCP 76.12(2)
-
Not serious
Action taken: Chris adjusted free chlori
Corrected on site
14a - CHLORINE TOO LOW (P)
The chlorine residual was 2.0ppm at the time of the inspection.
Correction: Close the pool and raise the chlorine residual to be within required range of 3.0ppm to a max of 10.0ppm.
Code ATCP 76.14(4)(a)
-
Not serious
Action taken:
20d - WATER TESTING - WHIRLPOOL, THERAPY, EXERCISE (Pf)
The water testing frequency for combined chlorine is not in compliance with ATCP 76.18(2). No recorded readings for combined chlorine observed on the testing log.
Correction: Perform water testing in accordance with ATCP 76.18(2). Test/record combined chlorine readings at least 2x/week.
Code ATCP 76.18(2)
-
Not serious
Action taken:
21d - READABLE CHART
There is no readable chart that describes the piping, valves, and direction of water flow. No pump curve available.
Correction: Labels, tags, or color coding shall correspond to a conspicuously posted, easily read chart that explains the system. Provide a pump curve and keep it available onsite.
Code ATCP 76.11(5m)(b)
-
Not serious
Action taken: Chris drained a portion of
Corrected on site
22c - WHIRLPOOL WATER TEMP (P)
The temperature of the whirlpool water is 105F, as measured by sanitarian's calibrated thermometer. Water heater was set to 102F and thermometer on recirculation piping indicates 102F.
Correction: Adjust the temperature to bring it within permissible limits pursuant to ATCP 76.19(4)(c). Do not exceed 104F.
Code ATCP 76.19(4)(c)
-
Not serious
Action taken:
-
Aug 7, 2024 Routine Inspection · No Reinspection Required
-
Not serious
Action taken: Chris had already posted a
Corrected on site
14c - CHLORINE TOO HIGH
The chlorine residual exceeded 10 ppm.
Correction: The pool must be closed and may not reopen until the chlorine residual comes into an acceptable range. Call inspector to notify of the Cl level.
Code ATCP 76.14(4)(f)
-
Not serious
Action taken:
16c - ALKALINITY
The total alkalinity is 40ppm.
Correction: Maintain the total alkalinity between 60 and 180 ppm.
Code ATCP 76.14(4)(d)
-
Not serious
Action taken:
20d - WATER TESTING - WHIRLPOOL, THERAPY, EXERCISE
The water testing frequency for combined chlorine is not in compliance with ATCP 76.18(2). CC only tested 1x/week.
Correction: Perform water testing in accordance with ATCP 76.18(2). Test CC 2x/week.
Code ATCP 76.18(2)
-
Not serious
Action taken: Chris had already posted a
Corrected on site
-
Jul 27, 2023 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
06a - SPARE STRAINER BASKET
A spare strainer basket(s) or screen for jet pump and the recirculation pump missing from pool pump room.
Correction: Provide a spare basket or screen for each pump and maintain in clean/working condition.
Code ATCP 76.11(2)(d)
-
Not serious
Action taken: Crystal contacted maintena
16a - pH
The pH is too high, 7.8-8.0.
Correction: Adjust pH for whirlpool to be between 7.2 and 7.8. Clean/recalibrate Chemtrol 250 probes, if needed.
Code ATCP 76.14(4)(c)
-
Not serious
Action taken: san emailed new pool testi
20d - WATER TESTING - WHIRLPOOL, THERAPY, EXERCISE
The water testing frequency for combined chlorine is not in compliance with ATCP 76.18(2).
Correction: Perform water testing in accordance with ATCP 76.18(2). Test / record results for combined chlorine 2x/week.
Code ATCP 76.18(2)
-
Not serious
Other
34e - VGBA COVERS
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken:
-
Jul 26, 2022 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
14a - CHLORINE TOO LOW
The chlorine residual was 1ppm at the time of the inspection.
Correction: Close the pool and raise the chlorine residual to . Call inspector to schedule a reopening inspection.
Code ATCP 76.14(4)(a)
-
Not serious
Action taken:
14e - WATER POTENTIAL ORP
The water potential was 602mV at the time of the inspection.
Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 850 mV.
Code ATCP 76.14(5)(a)
-
Not serious
Action taken:
16d - COMBINED CHLORINE
The combined chlorine is 1ppm.
Correction: Treat the pool with breakpoint chlorination using a chlorine product or a nonchlorinated oxidizer.
Code ATCP 76.14(4)(e)
-
Not serious
Action taken:
-
Aug 11, 2021 Routine Inspection · No Reinspection Required
No violations cited.
-
Aug 20, 2019 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 4, 2018 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 6, 2017 Re-Inspection · No Reinspection Required
No violations cited.
-
Jun 5, 2017 Routine Inspection · Reinspection Required
No violations cited.
-
May 26, 2016 Reinspection · No Reinspection Required
No violations cited.
-
May 20, 2016 Pre-Inspection · No Reinspection Required
No violations cited.