310 Samuel DR, Madison, WI 53717 · Dane County
Establishment
- Type
- Pool / recreational water (Swimming Pool)
- Inspected by
- Public Health Madison & Dane County
- License / ID
- LICSWD-2016-00131
- Official record
- Public Health Madison & Dane County inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 1 | 0 |
| 2024 | 1 | 1 | 0 |
| 2023 | 1 | 4 | 0 |
| 2022 | 2 | 5 | 0 |
| 2021 | 1 | 0 | 0 |
| 2019 | 1 | 0 | 0 |
| 2018 | 1 | 0 | 0 |
| 2017 | 1 | 0 | 0 |
| 2016 | 1 | 0 | 0 |
Inspections
-
Jun 12, 2026 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
31b - EQUIPMENT NOT MAINTAINED
Leak observed on recirculation system piping at pool heater, water leaking into pan on floor.
Correction: Repair and maintain all equipment.
Code ATCP 76.33(1)(e)
-
Not serious
Action taken:
-
Aug 7, 2024 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
31b - EQUIPMENT NOT MAINTAINED
Leak observed on recirculation system piping at pool heater, water leaking into pan on floor.
Correction: Repair and maintain all equipment.
Code ATCP 76.33(1)(e)
-
Not serious
Action taken:
-
Jul 27, 2023 Routine Inspection · No Reinspection Required
-
Not serious
Action taken: sanitarian recommended dra
16b - CYANURIC ACID
The cyanuric acid concentration is 80ppm.
Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.
Code ATCP 76.14(4)(b)
-
Not serious
Action taken: Crystal locked the gate th
Corrected on site
34a - GATES NOT MAINTAINED
The self-closing mechanism is not working for the gate in the fence that is nearest to the building.
Correction: Repair and maintain the gate. All gates/doors to the pool enclosure must be self-closing, self-latching, and lockable.
Code ATCP 76.34(2)
-
Not serious
Action taken: san emailed DATCP policy "
34c - DOOR/GATE
The men's and women's restroom doors to the pool enclosure are not self-latching.
Correction: Repair/replace the men's and women's restroom doors that open to the pool enclosure so that they are self-closing, self-latching, and is lockable.
Code ATCP 76.34(4)
-
Not serious
Other
34e - VGBA COVERS
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken: sanitarian recommended dra
-
Sep 22, 2022 Re-Inspection · No Reinspection Required
-
Not serious
Action taken:
30e - SOAP - Not Corrected
The soap dispenser located in the women's restroom is empty.
Correction: Provide soap at all hand washing sinks and showers.
Code ATCP 76.33(2)(e)
-
Not serious
Action taken:
31b - EQUIPMENT NOT MAINTAINED - Not Corrected
The Spa flowmeter is leaking.
Correction: Repair and maintain all equipment.
Code ATCP 76.33(1)(e)
-
Not serious
Action taken:
-
Jul 26, 2022 Routine Inspection · Reinspection Required
-
Not serious
Action taken:
26m - TELEPHONE - NOT WORKING
The pool emergency telephone does not work.
Correction: Provide a functional emergency telephone immediately.
Code ATCP 76.26(2)
-
Not serious
Action taken:
30e - SOAP
The soap dispenser located in the women's restroom is empty.
Correction: Provide soap at all hand washing sinks and showers.
Code ATCP 76.33(2)(e)
-
Not serious
Action taken:
31b - EQUIPMENT NOT MAINTAINED
The Spa flowmeter is leaking.
Correction: Repair and maintain all equipment.
Code ATCP 76.33(1)(e)
-
Not serious
Action taken:
-
Aug 11, 2021 Routine Inspection · No Reinspection Required
No violations cited.
-
Aug 20, 2019 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 4, 2018 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 5, 2017 Routine Inspection · Reinspection Required
No violations cited.
-
May 26, 2016 Pre-Inspection · No Reinspection Required
No violations cited.
Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.