Village Of Cross Plains Pool
2106 LEWIS ST, Cross Plains, WI 53528 · Dane County
Establishment
- Type
- Pool / recreational water (Swimming Pool)
- Inspected by
- Public Health Madison & Dane County
- License / ID
- 73397-81626
- Official record
- Public Health Madison & Dane County inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 2 | 0 |
| 2025 | 1 | 10 | 0 |
| 2023 | 1 | 2 | 0 |
| 2022 | 1 | 9 | 0 |
| 2021 | 1 | 0 | 0 |
| 2019 | 1 | 0 | 0 |
| 2017 | 1 | 0 | 0 |
| 2016 | 1 | 0 | 0 |
| 2015 | 1 | 0 | 0 |
| 2014 | 1 | 0 | 0 |
| 2013 | 1 | 0 | 0 |
| 2012 | 1 | 0 | 0 |
Inspections
-
Jul 27, 2026 Routine Inspection · No Reinspection Required
-
Not serious
Action taken: Plastic spine board with h
26h - RESCUE EQUIPMENT - ACCESSIBLE, GOOD REPAIR, SIZED (P)
Wooden spine board is weathered, rough, and missing attachments.
Correction: Remove or maintain in good repair.
Code ATCP 76.26(1)
-
Not serious
Action taken: Copy of file provided duri
Corrected on site
28f - FILES MAINTAINED
A copy of the most recent US CDC recommendations for fecal accidents is not permanently maintained on the premise.
Correction: Provide all files pursuant to ATCP 76.32(3).
Code ATCP 76.32(3)
-
Not serious
Action taken: Plastic spine board with h
-
Aug 19, 2025 Routine Inspection · No Reinspection Required
-
Not serious
Action taken:
11b - CHEMICAL - STORAGE (P)(Pf)
Door to chemical storage area is not locked nor marked to indicate entry for authorized personnel only.
Correction: Keep doors to chemical storage areas locked and mark door for authorized personnel only
Code ATCP 76.12(2)
-
Not serious
Action taken:
20e - WATER TESTING FREQUENCY - WITH ELECTRONIC MONITORING DEVICE (Pf)
The water testing frequency for cyanuric acid and combined chlorine are not in compliance with ATCP 76.18(3).
Correction: Perform water testing in accordance with ATCP 76.18(3). Test cyanuric acid once per week and combined chlorine twice per week.
Code ATCP 76.18(3)
-
Not serious
Action taken: Back flow preventer meetin
Corrected on site
21b - BACKFLOW - HOSE BIBBS (P)
The hose bibb is not protected against backsiphonage.
Correction: Install a hose bibb atmospheric vacuum breaker that meets the ASSE 1011 standard on the hose bibb.
Code ATCP 76.33(1)(d)
-
Not serious
Action taken: Minimum lifeguard requirem
25f - LIFEGUARD - CERTIFICATIONS MAINTAINED (P)
Some lifeguard certifications have expired.
Correction: The lifeguard must be relieved of duties until a current certification can be verified. If the minimum lifeguard requirements in the approved staffing plan are not met as a result, the guarded pool or portion must be closed.
Code ATCP 76.22(2)(a)
-
Not serious
Action taken: Plastic spine board with h
26h - RESCUE EQUIPMENT - ACCESSIBLE, GOOD REPAIR, SIZED (P)
Wooden spine board is weathered, rough, and missing attached head immobilizer.
Correction: Maintain in good repair.
Code ATCP 76.26(1)
-
Not serious
Action taken:
26t - BIOHAZARD SAFETY KIT (Pf)
No biohazard safety kit is located at the first aid station or on the premises.
Correction: Provide a biohazard safety kit with the items listed in ATCP 76.27(2)(b) at the first aid station or on the premise. 1. Scoop and spatula. 2. Sanitizing hand wipes. 3. Sanitizing surface wipes. 4. Neoprene gloves. 5. Paper toweling. 6. Biohazard disposal bag at least 24"X24". 7. Twist tie or other effective means to close the bag. 8. Biohazard sorbent. 9. Storage case.
Code ATCP 76.27(2)
-
Not serious
Action taken: Form provided with emailed
28e -REPORTS AND RECORDS (Pf)
Operational testing report is not completed on approved form.
Correction: Keep the following records available for review. (a) Chemical testing pursuant s. ATCP 76.14. (b) Backwashing completion. (c) Breakpoint chlorination. (d) Interlock testing. (e) Anti-entrapment system testing. (f) Water temperature. (g) Safety and rescue equipment maintaining pursuant to ss. ATCP 76.26 and ATCP 76.27. (h) If monthly reports are requested by the department or its agent, they shall
Code ATCP 76.32(1)
-
Not serious
Action taken:
30e - SOAP (Pf)
Soap dispensers are not provided at showers.
Correction: Provide soap at all hand washing sinks and showers.
Code ATCP 76.33(2)(e)
-
Not serious
Action taken:
32d - CARBON MONOXIDE ALARMS (P)
There is no carbon monoxide alarm in pool equipment room.
Correction: Install functioning carbon monoxide alarms.
Code ATCP 76.33(4)(d)
-
Not serious
Action taken: Surge tank door closed dur
Corrected on site
33a - HAZARDOUS MATERIAL (P)
Surge tank door propped open creating a fall hazard.
Correction: Close surge tank door when not in use.
Code ATCP 76.34(1)
-
Not serious
Action taken:
-
Aug 8, 2023 Routine Inspection · No Reinspection Required
-
Not serious
Action taken: Chemical containers dried
Corrected on site
11b - CHEMICAL - STORAGE
Chemicals are improperly stored in accordance with ATCP 76.12(2). Stored containers of calcium hypochlorite in the pump room are wet from dripping condensation from heater pipes.
Correction: Store chemicals in a clean, dry, well ventilated and locked area away from flammables, incompatible chemicals, and heat sources.
Code ATCP 76.12(2)
-
Not serious
Other
Repeat
34e - VGBA COVERS
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up. Email receipt to sanitarian.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken: Chemical containers dried
Corrected on site
-
Aug 4, 2022 Routine Inspection · No Reinspection Required
-
Not serious
Action taken: Container labeled.
Corrected on site
11a - CHEMICAL - LABELING
Large acid conatiner is not labeled according to ATCP 76.12(1).
Correction: Label the chemical container according to ATCP 76.12(1). Containers shall be conspicuously labeled with the following information: (a) Name of the product. (b) The manufacturer’s name and address. (c) Active ingredients. (d) Directions for use. (e) Hazardous ingredient warning. (f) The U.S. environmental protection agency registration number.
Code ATCP 76.12(1)
-
Not serious
Action taken:
20c - WATER TESTING - POOLS
The water testing frequency for alkalinity, combined chlorine, and cyanuric acid is not in compliance with ATCP 76.18(1).
Correction: Perform water testing in accordance with ATCP 76.18(1).
Code ATCP 76.18(1)
-
Not serious
Action taken:
21b - BACKFLOW - HOSE BIBBS
The hose bibb by the pump room is not protected against backsiphonage.
Correction: Install a hose bibb atmospheric vacuum breaker that meets the ASSE 1011 standard on the hose bibb.
Code ATCP 76.33(1)(d)
-
Not serious
Action taken: Proof of certification loc
Corrected on site
25e - LIFEGUARD - CERTIFICATIONS AVAILABLE
Lifeguard certification for one of the on-duty guards is not available.
Correction: The lifeguard must be relieved of duties until the certification can be verified. If the minimum lifeguard requirements in the approved staffing plan are not met as a result, the guarded pool or portion must be closed.
Code ATCP 76.22(2)(a)
-
Not serious
Action taken: Form emailed to operator.
28b - FECAL CONTAMINATION DOCUMENTATION
Documentation of fecal accidents in the facility are missing.
Correction: Document each fecal accident using DATCP fecal incident form and follow CDC guidelines for clean-up.
Code ATCP 76.31(2)
-
Not serious
Action taken:
28c - D-I-I REPORTS NOT SUBMITTED
An injury report from 5/30/22 was not submitted as required for an incident at the facility.
Correction: Submit the injury report on the discussed incident immediately to DATCP.
Code ATCP 76.32(2)
-
Not serious
Action taken: Soap provided at women's h
30e - SOAP
The soap dispenser by the hand sink closest to showers in women's locker room is empty. No soap is provided for women's or men's showers.
Correction: Provide soap at all hand washing sinks and showers.
Code ATCP 76.33(2)(e)
-
Not serious
Action taken: Gate locked.
Corrected on site
34c - DOOR/GATE
The gate to the pool enclosure by wading pool is open and no guard is stationed at the gate per approved variance.
Correction: Repair the door immediately so that it is self-closing, self-latching, and is lockable. Alternatively, lock gate and require all patrons and staff to use doors through locker rooms for entry.
Code ATCP 76.34(4)
-
Not serious
Other
34e - VGBA COVERS
No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.
Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.
Code ATCP 76.11(2)(b)
-
Not serious
Action taken: Container labeled.
Corrected on site
-
Jul 26, 2021 Routine Inspection · No Reinspection Required
No violations cited.
-
Aug 1, 2019 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 12, 2017 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 16, 2016 Routine Inspection · No Reinspection Required
No violations cited.
-
May 22, 2015 Routine Inspection · No Reinspection Required
No violations cited.
-
May 28, 2014 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 10, 2013 Routine Inspection · No Reinspection Required
No violations cited.
-
Jun 11, 2012 Routine Inspection · No Reinspection Required
No violations cited.
Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.