RecordWell Data

Waters Edge Condo II

3939 MONONA DR, Monona, WI 53716 · Dane County

28cited violations
0serious tier
15inspections

Establishment

Type
Pool / recreational water (Swimming Pool)
Inspected by
Public Health Madison & Dane County
License / ID
73414-81645
Official record
Public Health Madison & Dane County inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20262120
2025140
2024130
2023170
2022120
2021100
2019100
2018100
2017100
2016100
2015100
2014100
2013100
2012100

Inspections

  1. Aug 20, 2026 Re-Inspection · No Reinspection Required
    • Not serious Action taken:

      11e - SDS AVAILABILITY (Pf) - Not Corrected

      Safety data sheets are not available for all chemicals used in the facility.

      Correction: Provide safety data sheets for all chemicals used in the facility.

      Code ATCP 76.12(4)(b)

    • Not serious Action taken:

      16b - CYANURIC ACID (Pf) - Not Corrected

      The cyanuric acid concentration is 50 ppm.

      Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.

      Code ATCP 76.14(5)(b)

    • Not serious Action taken:

      20b - TEST KIT REAGENT STORAGE (Pf) - Not Corrected

      The test kit reagents are being used past their expiration date.

      Correction: Store reagents properly, in original containers, replace when expired.

      Code ATCP 76.17(2)

    • Not serious Action taken:

      20c - WATER TESTING - POOLS (Pf) - Not Corrected

      The water testing frequency for Free Chlorine, pH, Total Alkalinity, Combined Chlorine and Cyanuric Acid are not in compliance with ATCP 76.18(1).

      Correction: Perform water testing in accordance with ATCP 76.18(1).

      Code ATCP 76.18(1)

    • Not serious Action taken:

      33a - HAZARDOUS MATERIAL (P) - Not Corrected

      Main drain cover is missing a screw at the time of the inspection.

      Correction: Replace the exact screw like for like, close the pool until the missing screw is replaced.

      Code ATCP 76.34(1)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf) - Not Corrected

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date.

      Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.

      Code ATCP 76.38

  2. Aug 19, 2026 Routine Inspection · Immediate Suspension
    • Not serious Action taken:

      11e - SDS AVAILABILITY (Pf)

      Safety data sheets are not available for all chemicals used in the facility.

      Correction: Provide safety data sheets for all chemicals used in the facility.

      Code ATCP 76.12(4)(b)

    • Not serious Action taken:

      16b - CYANURIC ACID (Pf)

      The cyanuric acid concentration is 50 ppm.

      Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.

      Code ATCP 76.14(5)(b)

    • Not serious Action taken:

      20b - TEST KIT REAGENT STORAGE (Pf)

      The test kit reagents are being used past their expiration date.

      Correction: Store reagents properly, in original containers, replace when expired.

      Code ATCP 76.17(2)

    • Not serious Action taken:

      20c - WATER TESTING - POOLS (Pf)

      The water testing frequency for Free Chlorine, pH, Total Alkalinity, Combined Chlorine and Cyanuric Acid are not in compliance with ATCP 76.18(1).

      Correction: Perform water testing in accordance with ATCP 76.18(1).

      Code ATCP 76.18(1)

    • Not serious Action taken:

      33a - HAZARDOUS MATERIAL (P)

      Main drain cover is missing a screw at the time of the inspection.

      Correction: Replace the exact screw like for like, close the pool until the missing screw is replaced.

      Code ATCP 76.34(1)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf)

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date.

      Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.

      Code ATCP 76.38

  3. Aug 4, 2025 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      16b - CYANURIC ACID (Pf)

      The cyanuric acid concentration is 40 ppm.

      Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.

      Code ATCP 76.14(5)(b)

    • Not serious Action taken:

      20c - WATER TESTING - POOLS (Pf)

      The water testing frequency for Free Chlorine, Combined Chlorine and pH is not in compliance with ATCP 76.18(1).

      Correction: Perform water testing in accordance with ATCP 76.18(1).

      Code ATCP 76.18(1)

    • Not serious Action taken:

      26g - BREATH HOLDING PROHIBITION - SIGNAGE

      Breath holding prohibition is not posted or communicated to patrons.

      Correction: Provide signage or otherwise communicate to patrons that activites involving prolonged breath holding are prohibited.

      Code ATCP 76.29(1)(f)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf)

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make, model, gallons per minute rating, life span, and installation date.

      Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.

      Code ATCP 76.38

  4. Aug 27, 2024 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      16b - CYANURIC ACID

      The cyanuric acid concentration is 60 ppm.

      Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.

      Code ATCP 76.14(4)(b)

    • Not serious Action taken:

      16c - ALKALINITY

      The total alkalinity is 160 ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(4)(d)

    • Not serious Action taken:

      21c - DIRECTION OF FLOW

      The water treatment system piping is not marked with a permanent label indicating direction of flow.

      Correction: Mark the water treatment system piping to indicate direction of flow.

      Code ATCP 76.11(5m)

  5. Aug 21, 2023 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      06a - SPARE STRAINER BASKET

      A spare strainer basket(s) or screen for the the recirculation pump] is not located on site.

      Correction: Provide a spare basket or screen.

      Code ATCP 76.11(2)(d)

    • Not serious Action taken:

      11e - SDS AVAILABILITY

      Safety data sheets are not available for all chemicals used in the facility.

      Correction: Provide safety data sheets for all chemicals used in the facility.

      Code ATCP 76.12(4)(b)

    • Not serious Action taken:

      16b - CYANURIC ACID

      The cyanuric acid concentration is 60 ppm.

      Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.

      Code ATCP 76.14(4)(b)

    • Not serious Action taken:

      20c - WATER TESTING - POOLS

      The water testing frequency for Combined Chlorine, Total Alkalinity and Cyanuric Acid are not in compliance with ATCP 76.18(1).

      Correction: Perform water testing in accordance with ATCP 76.18(1).

      Code ATCP 76.18(1)

    • Not serious Action taken:

      21c - DIRECTION OF FLOW

      The water treatment system piping is not marked with a permanent label indicating direction of flow.

      Correction: Mark the water treatment system piping to indicate direction of flow.

      Code ATCP 76.11(5m)

    • Not serious Action taken:

      22a - THERMOMETER

      There is no functional thermometer installed on the pool water return line.

      Correction: Install a working thermometer on the pool water return line.

      Code ATCP 76.19(4)(a)

    • Not serious Action taken:

      24b - LIFEGUARD - SIGNAGE MISSING

      A pool basin in the facility does have a 'No Lifeguard on Duty' sign, but it's less than 4 inches.

      Correction: Provide a 'No Lifeguard on Duty Sign' with 4 inch letters.

      Code ATCP 76.22(1)(c); ATCP 76.23(2)

  6. Aug 12, 2022 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      09a - FLOW METER

      Numbers and lines on flow meter have faded. Meter is hard to read.

      Correction: Replace the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken:

      16b - CYANURIC ACID

      The cyanuric acid concentration is 70.

      Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.

      Code ATCP 76.14(4)(b)

  7. Jul 14, 2021 Routine Inspection · No Reinspection Required

    No violations cited.

  8. Aug 8, 2019 Routine Inspection · No Reinspection Required

    No violations cited.

  9. Jun 27, 2018 Routine Inspection · No Reinspection Required

    No violations cited.

  10. Jun 30, 2017 Routine Inspection · No Reinspection Required

    No violations cited.

  11. Jun 17, 2016 Routine Inspection · No Reinspection Required

    No violations cited.

  12. Jun 25, 2015 Routine Inspection · No Reinspection Required

    No violations cited.

  13. Jun 9, 2014 Routine Inspection · No Reinspection Required

    No violations cited.

  14. Jun 19, 2013 Routine Inspection · No Reinspection Required

    No violations cited.

  15. May 30, 2012 Routine Inspection · No Reinspection Required

    No violations cited.

Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.