YearInspectionsViolationsSerious
20262150
2025270
20243100
2022150
2019100
2018100
2017300
2015200
2013100
2012100

Inspections

  1. Aug 10, 2026 Re-Inspection · No Reinspection Required
    • Not serious Action taken: Repeat

      04a - SKIMMER FUNCTION (Pf) - Not Corrected

      The West side skimmer is not adequately removing surface debris.

      Correction: Readjust the flow through the skimmers to maintain vigorous skimming action through all skimmers.

      Code ATCP 76.11(2)(a)

    • Not serious Action taken: Repeat

      04c - SKIMMER BASKET/WEIR - Not Corrected

      The shallow end skimmer basket or weir is broken and missing.

      Correction: Replace.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken: Repeat

      06a - SPARE STRAINER BASKET - Not Corrected

      A spare strainer basket(s) or screen for the skimmers and the recirculation pump is not located on site.

      Correction: Provide a spare basket or screen.

      Code ATCP 76.11(2)(d)

    • Not serious Action taken:

      29b - BASIN MAINTENANCE AND REPAIR - Not Corrected

      The pool basin has etching along the top of the pool and on the bottom of the pool.

      Correction: Maintain the pool basin in a clean, sanitary condition and free from cracks and defects.

      Code ATCP 76.33(1)(a)

    • Not serious Action taken: Repeat

      29d - DECK MAINTENANCE AND CLEANING (Pf) - Not Corrected

      The pool deck is not maintained in good repair, and is chipping and cracks are visible.

      Correction: Maintain in good repair and clean and sanitize the deck according to ATCP 76.33 (1)(b).

      Code ATCP 76.33(1)(b)

  2. Aug 5, 2026 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      04a - SKIMMER FUNCTION (Pf)

      The West side skimmer is not adequately removing surface debris.

      Correction: Readjust the flow through the skimmers to maintain vigorous skimming action through all skimmers.

      Code ATCP 76.11(2)(a)

    • Not serious Action taken:

      04c - SKIMMER BASKET/WEIR

      The shallow end skimmer basket or weir is broken and missing.

      Correction: Replace.

      Code ATCP 76.11(2)(b)

    • Not serious Action taken:

      05a - SKIMMER/MAIN DRAIN RATIO (Pf)

      The skimmer to main drain flow ratio is not set correctly. Main drain valve is wide open and skimmer valve is about 80% open.

      Correction: Readjust the flow so that on pool with skimmers, only 20% of the flow comes through the main drain and 80% comes through the skimmers. On a gutter pool, 75% of the required recirculation flow shall be through the gutter and 25% through the main drain. For reverse flow pools, 100% recirculation must be through gutter or skimmers.

      Code ATCP 76.11(2)(a)

    • Not serious Action taken:

      06a - SPARE STRAINER BASKET

      A spare strainer basket(s) or screen for the skimmers and the recirculation pump is not located on site.

      Correction: Provide a spare basket or screen.

      Code ATCP 76.11(2)(d)

    • Not serious Action taken:

      14e - WATER POTENTIAL ORP (Pf)

      The water potential was 644 mV at the time of the inspection.

      Correction: Manually test the pool water and recalibrate the oxidation potential controller if needed to maintain the water potential between 650 to 900 mV.

      Code ATCP 76.14(5)(a)

    • Not serious Action taken:

      20e - WATER TESTING FREQUENCY - WITH ELECTRONIC MONITORING DEVICE (Pf)

      The water testing frequency for combined chlorine and cyanuric acid is not in compliance with ATCP 76.18(3).

      Correction: Perform water testing in accordance with ATCP 76.18(3).

      Code ATCP 76.18(3)

    • Not serious Action taken:

      26f - PATRON LOAD - NOT POSTED (Pf)

      The maximum patron load is not posted in the facility.

      Correction: Post the maximum patron load conspicuously near each pool.

      Code ATCP 76.29(1)(e)

    • Not serious Action taken:

      29b - BASIN MAINTENANCE AND REPAIR

      The pool basin has etching along the top of the pool and on the bottom of the pool.

      Correction: Maintain the pool basin in a clean, sanitary condition and free from cracks and defects.

      Code ATCP 76.33(1)(a)

    • Not serious Action taken:

      29d - DECK MAINTENANCE AND CLEANING (Pf)

      The pool deck is not maintained in good repair, and is chipping and cracks are visible.

      Correction: Maintain in good repair and clean and sanitize the deck according to ATCP 76.33 (1)(b).

      Code ATCP 76.33(1)(b)

    • Not serious Other

      34f - VGBA COVERS DOCUMENTATION (Pf)

      The East side screw is missing from both main drain covers, and there is a chunk missing from the South side main drain covers near the East side screw hole.

      Correction: Maintain documentation (log, receipts, or affidavits from a pool service company) of VGBA covers for main drain and equalizers on site and available for review during inspection. Documentation shall include the following: 1. Make 2. Model 3. Gallons per minute rating. 4. Life span. 5. Installation date.

      Code ATCP 76.38

  3. Jul 15, 2025 Re-Inspection · No Reinspection Required
    • Not serious Action taken:

      26s - BLANKETS MISSING (Pf) - Not Corrected

      2 conventional or emergency blankets are not available in the pool area.

      Correction: Provide 2 conventional or emergency blankets in the pool area.

      Code ATCP 76.27(1)(3)

    • Not serious Action taken:

      29b - BASIN MAINTENANCE AND REPAIR - Not Corrected

      The pool basin paint is chipping away in a few places towards the deep end of the pool. The pool basin is chipping away near one edge of the main drain cover closest to the North side of the pool.

      Correction: Maintain the pool basin in a clean, sanitary condition and free from cracks and defects.

      Code ATCP 76.33(1)(a)

  4. Jul 8, 2025 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      08a - RECIRCULATION RATE - SWIM/COMBO (Pf)

      The swimming pool or combination pool has a maximum turnover rate of greater than 6 hours. Turnover rate calculated to be 8.4 hours at time of inspection.

      Correction: Work with pool maintenance company to immediately adjust or repair the equipment so the turnover rate does not exceed 6 hours.

      Code ATCP 76.11(4)(c)

    • Not serious Action taken: Repeat

      16b - CYANURIC ACID (Pf)

      The cyanuric acid concentration is 50 ppm.

      Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.

      Code ATCP 76.14(5)(b)

    • Not serious Action taken:

      21b - BACKFLOW - HOSE BIBBS (P)

      The hose bibb by the pump room is not protected against backsiphonage.

      Correction: Install a hose bibb atmospheric vacuum breaker that meets the ASSE 1011 standard on the hose bibb.

      Code ATCP 76.33(1)(d)

    • Not serious Action taken:

      26s - BLANKETS MISSING (Pf)

      2 conventional or emergency blankets are not available in the pool area.

      Correction: Provide 2 conventional or emergency blankets in the pool area.

      Code ATCP 76.27(1)(3)

    • Not serious Action taken:

      29b - BASIN MAINTENANCE AND REPAIR

      The pool basin paint is chipping away in a few places towards the deep end of the pool. The pool basin is chipping away near one edge of the main drain cover closest to the North side of the pool.

      Correction: Maintain the pool basin in a clean, sanitary condition and free from cracks and defects.

      Code ATCP 76.33(1)(a)

  5. Jul 22, 2024 Re-Inspection · No Reinspection Required

    No violations cited.

  6. Jul 8, 2024 Re-Inspection · Reinspection Required
    • Not serious Action taken: Repeat

      16b - CYANURIC ACID - Not Corrected

      The cyanuric acid concentration is 50 ppm.

      Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.

      Code ATCP 76.14(4)(b)

    • Not serious Action taken:

      29g - DRINKING FOUNTAIN - Not Corrected

      The drinking fountain is not functional.

      Correction: Repair/clean the drinking fountain.

      Code ATCP 76.33(1)(g)

  7. Jun 26, 2024 Routine Inspection · Reinspection Required
    • Not serious Action taken:

      05a - SKIMMER/MAIN DRAIN RATIO

      The skimmer to main drain flow ratio is not set correctly. Both skimmer drain and main drain pipes are 100% open.

      Correction: Readjust the flow so that on skimmer pool, only 20% of the flow comes through the main drain and 80% comes through the skimmers. On a gutter pool, 75% of the required recirculation flow shall be through the gutter and 25% through the main drain.

      Code ATCP 76.11(2)(a)

    • Not serious Action taken: Repeat

      09a - FLOW METER

      The flow meter is not functional.

      Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken: Repeat

      16b - CYANURIC ACID

      The cyanuric acid concentration is 50 ppm.

      Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.

      Code ATCP 76.14(4)(b)

    • Not serious Action taken:

      26o - EMERGENCY NUMBERS AND ADDRESS

      The emergency address posted (1703 Wispering Pines Way) does not correspond with what the 911 operator had on file (1400 Whispering Pines Way).

      Correction: Post the correct emergency numbers near the designated emergency phone.

      Code ATCP 76.26(2)

    • Not serious Action taken:

      26s - BIOHAZARD SAFETY KIT

      No biohazard safety kit is located on the premises.

      Correction: Provide a biohazard safety kit at the first aid station.

      Code ATCP 76.27(2)

    • Not serious Action taken:

      29g - DRINKING FOUNTAIN

      The drinking fountain is not functional.

      Correction: Repair/clean the drinking fountain.

      Code ATCP 76.33(1)(g)

    • Not serious Action taken:

      31b - EQUIPMENT NOT MAINTAINED

      Left side of pool step railing on the North and East side of the pool are loose.

      Correction: Repair and maintain all equipment.

      Code ATCP 76.33(1)(e)

    • Not serious Other Repeat

      34e - VGBA COVERS

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  8. Sep 2, 2022 Routine Inspection · No Reinspection Required
    • Not serious Action taken:

      09a - FLOW METER

      The flow meter is not functional.

      Correction: Repair or replace the flowmeter so an accurate rate of flow can be recorded.

      Code ATCP 76.11(5)

    • Not serious Action taken:

      16b - CYANURIC ACID

      The cyanuric acid concentration is 70ppm.

      Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.

      Code ATCP 76.14(4)(b)

    • Not serious Action taken:

      20c - WATER TESTING - POOLS

      The water testing frequency for pH, free chlorine and cyanuric acid is not in compliance with ATCP 76.18(1).

      Correction: Perform water testing in accordance with ATCP 76.18(1). Test and record pH and free chlorine at least 2x/day, cyanuric acid at least 1x/week.

      Code ATCP 76.18(1)

    • Not serious Action taken:

      29b - BASIN DEFECTS

      The pool basin is pitted/chipping above the water line in the basin.

      Correction: Repair the pool basin so it is finished and easily cleanable.

      Code ATCP 76.33(1)(a)

    • Not serious Other

      34e - VGBA COVERS

      No documentation is available on site for VGBA main drain and/or equalizer covers showing make/model, installation, and replacement date.

      Correction: Maintain documentation of VGBA covers for main drain and equalizers on site and available for review during inspection. Replace covers when lifespan is up.

      Code ATCP 76.11(2)(b)

  9. Aug 27, 2019 Routine Inspection · No Reinspection Required

    No violations cited.

  10. Jun 21, 2018 Routine Inspection · No Reinspection Required

    No violations cited.

  11. Jul 18, 2017 Re-Inspection · No Reinspection Required

    No violations cited.

  12. Jul 14, 2017 Re-Inspection · Reinspection Required

    No violations cited.

  13. Jun 19, 2017 Routine Inspection · Reinspection Required

    No violations cited.

  14. Sep 1, 2015 Routine Inspection · No Reinspection Required

    No violations cited.

  15. Jun 1, 2015 Routine Inspection · No Reinspection Required

    No violations cited.

  16. Jul 18, 2013 Routine Inspection · No Reinspection Required

    No violations cited.

  17. Jul 25, 2012 Routine Inspection · No Reinspection Required

    No violations cited.

Source: Public Health Madison & Dane County. History last read Nov 2, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.